• 제목/요약/키워드: Effluent concentration

검색결과 796건 처리시간 0.027초

그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발 (Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module))

  • 김정숙;김미란;조명찬;장정국
    • 한국환경과학회지
    • /
    • 제21권12호
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

급속모래여과에서 PAC 피복에 의한 초기 유출수의 탁도 개선 (Improving the Initial Effluent Turbidity by Polyaluminium Chloride(PAC) Coating in Rapid Sand Filtration)

  • 윤태한;김우항
    • 한국물환경학회지
    • /
    • 제18권3호
    • /
    • pp.253-260
    • /
    • 2002
  • The purpose of this research was to describe the mechanisms and prevention of initial degradation in turbidity of the sand filter effluent. The method used was by adding a coagulant (PAC) to the sand filter after backwashing as a means of reducing turbidity. It was found that adding 80 mg/L of PAC solution to the sand filter was very effective in improving the initial effluent turbidity. A turbidity removal efficiency of 99 % was observed in the initial term period as compared to a 70% efficiency without PAC addition. The PAC solution added to the sand filter resulted in high aluminum concentration at the upper layer as compared with the bottom layer of the sand filter column. A change in the zeta potential to a strong positive-ions at upper layer was observed at this time but only a small change was obtained at the bottom. This result showed that the zeta potential of the sand was changed to positive with PAC coating. The effect of pH on zeta potential with PAC addition was also investigated. Zeta potential was greatly changed to positive-ion at pH 4~6. A series of experiments was then conducted in this study to optimize the pH of the PAC solution to be added to the sand filter after backwashing. The removal efficiency of turbidity was found to be highest at pH 5. This result suggested that hydrolyzed aluminium species attached to the surface of the sand enhanced the removal of turbidity of the effluent.

인공습지 오수처리시설의 처리성능에 관한 연구 (Study on the Performance of Constructed Wetland System for Sewage Treatment)

  • 윤춘경
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.96-105
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the performance of constructed wetland system for wastewater treatment in rural area. The constructed wetland system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand bed with planted reed. From August 1996 to June 1998 the hydraulic loading rate was fixed with about 15.63cm/day and theoretical detention time was 1.38 days, and from July 1998 to December 1999 the hydraulic loading rate was about 6.25cm/day and theoretical detention time was 3.5days. It worked continuously even during winter time, and the sewage flowed without freezing even when average daily air temperature was below -1$0^{\circ}C$. Average removal rate of BOD , COD, and SS was about 70%, T-P removal rate was about 50.8% , and T-N removal rate was 23.9%. The reason for poor T-N removal might be due to high influent concentration and short retention times. At the later years BOD and COD removal rates were increased , and SS and T-P removal rates did not change significantly , but T-N removal rates were decreased. The effluent of the wetland system often effluent water quality standards for sewage treatment plant, therefore, further treatment would be required if the effluent need to be discharged to the public water. Wetland system involves relatively large land area and could be suitable for rural area. Therefore, utilization of reclaimed sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage in rural area.

  • PDF

하수처리장 방류수 수질예측을 위한 다중회귀분석 모델 개발 및 검증 (Development and Validation of Multiple Regression Models for the Prediction of Effluent Concentration in a Sewage Treatment Process)

  • 민상윤;이승필;김진식;박종운;김만수
    • 대한환경공학회지
    • /
    • 제34권5호
    • /
    • pp.312-315
    • /
    • 2012
  • 본 연구는 Media공법을 적용하고 있는 하수처리장의 실데이터를 활용하여 다중회귀분석을 통해 유출수질을 예측하는 모형을 구현하였다. 다중회귀분석은 2011년 1년간 데이터를 사용하였으며, 변수선택법 적용, 이상치와 영향치 제거, 변수의 로그변환에 따른 CASE별 연구를 수행하였다. 다중회귀분석으로 구축된 예측 모형으로 예측정확도를 검토한 결과, 2차침전지 유출수 $COD_{Mn}$는 0.87 이상, T-N은 0.81 이상으로 검토되었으며, 구축된 다중회귀모형을 이용하여 유출수가 방류수질기준을 초과하지 않는 운전조건의 범위를 설정할 수 있을 것으로 판단된다. 결론적으로 설정된 운전조건 범위 안에서 수질측면과 에너지 비용측면으로 하수처리장 운영시 운전자에게 적절한 운전 가이드를 제공할 수 있을 것으로 판단된다.

분리막이 결합된 무산소·호기 공정을 이용한 축산폐수처리에서 수리학적체류시간 및 내부반송율이 유기물 및 질소제거에 미치는 영향 (Effect of HRT and Internal Recycle Ratio on Removal of Organic and Nitrogen in Swine Wastewater by Anoxic-Oxic Process Combined with Membrane)

  • 황규대;이봉희;이현덕
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.603-609
    • /
    • 2004
  • The objective of this study was to determine the optimal operation conditions in an anoxic oxic process to eliminate both organic and nitrogen matters in swine wastewater. For the purpose of this, the removal efficiency was evaluated with various HRTs and internal recycling ratio. During the whole 580 days of experiment, HRTs had been gradually decreased in an order of 20, 14, 12 and l0days, and the internal recycle ratio was kept at 20Q. So as to determine the effect of the internal recycle ratio on the nitrogen removal, the internal recycle ratio had been gradually increased from 20Q to 50Q while HRT was maintained at 12days. As a result, it was shown that the removal efficiency of organic matter was above 95% regardless of changing of HRTs. The average influent concentration of TCODcr and SCODcr were 24,854 mg/L and 18,920 mg/L, respectively. Average removal efficiency of TKN was shown to be nearly 98% when HRT was kept at 12days; however, the $NH_4{^+}-N$ concentration of effluent was shown to be increased when the loading rate of $NH_4{^+}-N$ was increased to $0.602 kgNH_4{^+}-N/m^3$-day by means of decreasing HRT to 10days. It was concluded that nitrogen loading rates should be more considered rather than organic loading rates in case of determining an optimal HRT. When gradually increasing the internal recycle ratio from 20Q to 50Q, the removal efficiency of organic matters and TKN were 96% and 98%, respectively so that no significant changes in removal efficiency was detected. However, when the internal recycle ratio was kept at 50Q, it was revealed that the $NO_3-N$ concentration of effluent seemed to drop and the average $NO_3-N$ concentration of effluent was around 52 mg/L.

Pseudomonas sp. B3를 이용한 Phenol 함유 폐수의 처리 (Treatment of Wastewater Containing Phenol Using Pseudomonassp. B3)

  • 강선태;김정목
    • KSBB Journal
    • /
    • 제11권4호
    • /
    • pp.476-480
    • /
    • 1996
  • Using Pseudomonas sp. B3, identified and isolated from nature, wastewater containing phenol was treated in a continuous stirred tank reactor and its reaction characteristics were studied. Average concentrations of phenol and COD in effluents were 1.5mg/L and 124mg/L at 0.059h-1 dilution rate, respectively. At the dilution rate higher than 0.063h-1, phenol and COD increased abruptly to 19mg/L and 318mg/L. At the dilution rate higher than 0.059h-1, biomass concentration suddenly decreased and was "washed out". Biomass concentration was 150mg/L at a dilution rate of 0.067h-1. Maximum biomass production rate was 15.98mg/L$.$h at a dilution rate of 0.067h-1. When dilution rate increased above 0.059h-1, effluent phenol concentration abruptly increased and biomass production rate decreased. Maximum cell growth rate(${\mu}$max) and Michaelis-Mentens kinetic constant(Ks) were 0.074h-1 and 0.424mg/L, respectively. From the above result low phenol concentration can be expected at a maximum dilution rate, but reactor becomes unstable due to phenol inhibition.

  • PDF

활성탄 흡착에 의한 해수중의 보론 제거 (Removal of boron in seawater by activated carbon adsoprtion)

  • 김한승;강준석;김병로
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.917-922
    • /
    • 2011
  • Adsorption characteristics of boron on activated carbon was investigated in order to evaluate the use of activated carbon for the removal of boron in desalination processes using SWRO. Boron was removed ranging from 54~60% when the concentration of activated carbon was 1,000 mg/L in 6 hours under the initial boron concentration of 5 mg/L. The removal of boron increased by 20~22% with the increase of pH from 5 to 9. Organic matter had adverse effect on the adsorption of boron on activated carbon. Boron removal decreased by 10-12% when EDTA was added at 1 mg/L under 5 mg/L of boron and 200mg/L of activated carbon. In this results, activated carbon would be a good candidate for a pretreatment of desalination processes by SWRO from the view of mitigating the feed boron concentration to RO and meeting the effluent boron concentration without post-treatment after RO.

하수방류수의 대장균군 발생에 영향을 미치는 수질인자에 관한 연구 (Studies on the Effect of Water Quality Parameters on Total Coliform Concentrations in Sewage Effluents)

  • 백영석;손진식
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.166-171
    • /
    • 2006
  • The objectives of the present paper were to investigate the concentration of total coliform in wastewater effluents and the effect of water chemical and physical characters in it. The most correlated parameter with total coliform was COD. It means that the wastewater treatment efficient effects on total coliform concentration. And we developed predictive model for the total coliform concentration. The estimated parameters for model were COD, temperature, nitrite, chloride, Mn and regression model equation was determined; log (Total Coli.) = 1.861+0.065[COD]+0.038[temperature]-0.0004[$Cl^-$]+3.697[Mn]-0.32 [$NO_2-N$] The developed model provided very strong correlation ($R^2:0.82$) between total coliform and regression equation. The parameters having high sensitivity were COD and temperature. So the study indicated that if the temperature and COD of wastewater effluent were known, we would estimate the concentration of total coliform and decide the most effective usage of chlorine.

계면활성제 원위치 토양 세정법을 이용한 유류 오염 지역 토양.지하수 정화 실증 시험 (Surfactant Enhanced In-Situ Soil Flushing Pilot Test for the Soil and Groundwater Remediation in an Oil Contaminated Site)

  • 이민희;정상용;최상일;강동환;김민철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권4호
    • /
    • pp.77-86
    • /
    • 2002
  • 유류, 특히 경유와 윤활류로 오염된 지역에서, 원위치 토양 세정법(In-situ soil flushing)을 이용하여 오염된 토양과 지하수를 동시에 정화하였다. 연구 지역은 부산시에 위치한 4.5 m(가로) $\times$ 4.5 m(세로) $\times$ 6.0 m(깊이) (총 121.5 $\textrm{m}^2$) 규모의 유류 오염지역으로.사질 및 미사질층이 혼합되어 나타나는 평균 수리전도도가 2.0 $\times$ 1$10^{-4}$cm/sec인 불균질 토양으로 이루어진 부지이다. 오염지역 지하수에 비이온 계면활성제 sorbitan monooleate(POE 20) 2%와 이소프로필알콜 0.07%를 혼합한 용액을 이용하여 약 3 공극체적(pore volume)을 세정하였으며, 지하수만을 이용하여 계면활성제 용액 세정 이전과 세정 이후 각 1공극체적을 세정에 이용하였다(총 5 공극체적). 총 4개의 주입정을 이용하여 각 주입정당 1.8 l/min-0.5 l/min의 속도로 주간(8시간)에 연속 주입하였으며, 2개의 채수정을 이용하여 야간에는 1시간 간격과 주간에는 30분 간격으로 2분간 채수하였다. 분석을 위한 시료 채수는 매일 아침 9시와 저녁 5시에 각 채수정으로부터 200$m\ell$ 이상 채수하였으며, 채수 용액을 저장하는 혼합저장 탱크에서의 시료 채취도 병행하였다. 토양 세정기간동안 채수정으로부터 채수된 유출용액은 모두 저장탱크에 저장되었다가, 지하수처리 장치에 의해서 유류와 중금속, 고형물들을 제거한 후 배출되어졌으며, 토양 내 TPH(total petroleum hydrocarbon) 농도가 토양오염 우려기준치 이하로, 유출된 지하수는 폐수배출허용기준을 만족할 때까지 토양 세정을 실시하였다. 처리 지하수만을 이용한 세정의 경우 채수정의 유출수 TPH농도는 10ppm이하였다. 계면활성제 용액을 이용한 세정의 경우 채수정의 최대 TPH 유출 농도는 1761 ppm으로서 처리지하수만을 이용하였을 때보다 170배 이상 증가하였으며, 세정기간 동안 두 개의 채수정으로부터 약 18.5kg의 유류(TPH)가 제거되었다. 계면활성제 용액 세정시 유출수는 유류의 농도뿐만 아니라 중금속 농도도 함께 증가하였으며, 이러한 현상은 오염토양의 중금속 정화에도 유리하게 사용될 수 있다고 사료된다. 유류로 오염된 실제 지역의 불균질 토양과 지하수를 계면활성제를 이용한 원위치 세정법으로 효율적으로 정화함으로서, 실험실 연구에 제한되었던 원위치 세정법의 효율을 현장 오염 지역에서 증명할 수 있었고, 원위치 토양 세정법이 실제 오염지역의 토양$\boxUl$지하수 정화에 효과적으로 사용될 수 있음을 입증하였다.

폐기물매립지 침출수에서 황산염환원균의 분포와 중금속 불용화역할 (Distribution of Sulfate-reducing Bacteria in Landfill Leachate and their Role on Insolubilization of Heavy metals)

  • Jung, Kweon;Shin, Jai-Young;Jung, Il-Hyun;Takamizawa, Kazuhiro;Yoo, Young-Sik
    • 한국환경보건학회지
    • /
    • 제23권3호
    • /
    • pp.27-39
    • /
    • 1997
  • This study, collaborated Gifu University, Japan, was performed to analyze chemical pollutants and microorganism and to clarify the distribution of sulfate-reducing bacteria and their insolubilization of heavy metal ions in leachates sampled seasonally between 1994 and 1996 from Nanjido waste landfill site, sampled 4 times between 1995 and 1996 from Pusan and Daejeon waste landfill site, and sampled 1 time between 1992 and 1994 from Hokkaido, Nagoya, Osaka and Hukuoka waste landfill site in Japan. The results were as follows: 1. The temperatures of internal leachate and leachate effluent were 40$\circ$C and 30$\circ$C, respectively, and the pH values of both leachates were about 8.0 at Nanjido waste landfill site. The concentration of SO$_4^{-2}$ gradually increased with the degree of stabilization and that of NO$_3$-N was detected in a part of sampling sites at one and half years, and in all sampling sites at 3 years after completion of landfill. 2. The organic substances in leachate of Nanjido waste landfill site decreased with the degree of stabilization and they were very fluctuated with measuring point and time. The concentration of organic substance and heavy metals in internal leachate were higher than in leachate effluent and those of Cd, Hg, and Pb were lower than detection limit except a part of samples in 1996. 3. APCs in internal leachate and leachate effluent were not much different and the minimum of APCs in internal leachate and leachate effluent were $1.0\times 10^4$/ml and $4.0\times 10^1$/ml, respectively. 4. The maximums of SRBs in Nanjido, Pusan, and Daejeon waste landfill site were 9180 MPN/ml, 24000 MPN/ml, and 348 MPN/ml, respectively and the maximum of SRBs in Japan waste landfill site was 9300 MPN/ml. 5. During 2-week-SRB culture, the values of MPN were high at 50$\circ$C for initial culture period and at 30$\circ$C for last culture period. MPN started to appear at first day and rapidly increased between 7th day and 9th day. 6. Cadmium and copper were insolubilized by SRB within 6 hr and iron and zinc were done within 48 hr. The rates of insolubilization of Cd, Cu, Fe, Zn, T-Cr were 100%, 99.5%, 95.0%, 99.8%, 16.1% after 48 hr treatment with SRB, respectively.

  • PDF