• Title/Summary/Keyword: Efficiency Factor

Search Result 3,848, Processing Time 0.025 seconds

New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit (결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

Balanced Forward-Flyback Converter for High Efficiency and High Power Factor LED Driver (고효율 및 고역률 LED 구동회로 위한 Balanced Forward-Flyback 컨버터)

  • Hwang, Min-Ha;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.492-500
    • /
    • 2013
  • A balanced forward-flyback converter for high efficiency and high power factor using a foward and flyback converter topologies is proposed in this paper. The conventional AC/DC flyback converter can achieve a good power factor but it has the high offset current through the transformer magnetizing inductor, which results in a large core loss and low power conversion efficiency. And, the conventional forward converter can achieve the good power conversion efficiency with the aid of the low core loss but the input current dead zone near zero cross AC input voltage deteriorates the power factor. On the other hand, since the proposed converter can operate as the forward and flyback converters during switch turn-on and turn-off periods, respectively, it cannot only perform the power transfer during an entire switching period but also achieve the high power factor due to the flyback operation. Moreover, since the current balanced capacitor can minimize the offset current through the transformer magnetizing inductor regardless of the AC input voltage, the core loss and volume of the transformer can be minimized. Therefore, the proposed converter features a high efficiency and high power factor. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency (변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정)

  • Kim, Chong-Min;Kim, Young-Seog;Gil, Hyoung-Jun;Shong, Kil-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

Efficiency factor of high calcium Class F fly ash in concrete

  • Sata, V.;Khammathit, P.;Chindaprasirt, P.
    • Computers and Concrete
    • /
    • v.8 no.5
    • /
    • pp.583-595
    • /
    • 2011
  • This paper studied the cement efficiency factor (k factor) of high calcium Class F fly ash. This k factor represents a unit of fly ash with efficiency equivalent to k unit of cement. The high calcium Class F fly ash was used to replace cement in concrete. The modified Bolomey's law with linear relationship was used for the analysis of the result of compressive strength, cement to water ratio (c/w) and fly ash to water ratio (f/w) by using the multi-linear regression to determine the k factor and other constants in the equations. The results of analysis were compared with the results from other researcher and showed that the k factor of high calcium Class F fly ash depends on the fineness of fly ash, replacement level and curing age. While the amount of CaO content in Class F fly ash not evident. Furthermore, necessary criteria and variables for the determination of the k factor including the use of the k factor in concrete mix design containing fly ash were proposed.

Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor (자본회수계수를 고려한 고효율 생산설비의 경제성분석)

  • Park, Hyung-Joon;Chung, Chcn-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.117-123
    • /
    • 2007
  • This paper is about the economic analysis of the replacement of electric facilities in the production facilities. As the interest of energy is increasing, the efficiency of facilities become more important. So, in this paper, we diagnosed facilities, especially electric motors, in the plant and calculated the operating efficiency, power loss with the load factor. And when we replace these facilities into high-efficiency motors, we also calculated new energy efficiency, energy loss and economic analysis through capital recovery factor. As a result, we economically proved that using high-efficiency motor is more beneficial than using non-high-efficiency motors in the model process.

Approximation of most penetrating particle size for fibrous filters considering Cunningham slip correction factor

  • Jung, Chang Hoon;Yoon, Young Jun;Um, Junshik;Lee, Seoung Soo;Lee, Ji Yi;Chiao, Sen;Kim, Yong Pyo
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.439-445
    • /
    • 2020
  • In the estimation of the aerosol single fiber efficiency using fibrous filters, there is a size range, where the particles penetrate most effectively through the fibrous collectors, and corresponding minimum single fiber efficiency. For small particles in which the diffusion mechanism is dominant, the Cunningham slip correction factor (Cc) affects the single fiber efficiency and the most penetrating particle size (MPPS). Therefore, for accurate estimation, Cc is essential to be considered. However, many previous studies have neglected this factor because of its complexity and the associated difficulty in deriving the appropriate parameterization particularly for the MPPS. In this study, the expression for the MPPS, and the corresponding expression for the minimum single fiber efficiency are analytically derived, and the effects of Cc are determined. In order to accommodate the slip factor for all particle-size ranges, Cc is simplified and modified. Overall, the obtained analytical expression for the MPPS is in a good agreement with the exact solution.

Characteristic of efficiency and powerfactor according to condition by polearcs and switching an91e for switched reluctance motor considering driving circuits (구동회로를 고려한 스위치드 릴럭턴스 전동기의 극호와 스위칭 조건에 따른 역율과 효율 특성)

  • Park, Jong-Won;Kim, Youn-Hyun;Choi, Jae-Hak;Lee, Ju;Kim, Suk-Tae;Kim, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.702-704
    • /
    • 2001
  • This paper investigates efficiency and power factor of Switched Reluctance Motor (SRM) using Finite Element Method considered driving circuit. The efficiency and power factor are calculated in Input terminal and Output terminal respectively. When calculating power factor, apparent power is obtained by effective voltage and current because SRM is operated by switching of driving circuit. Efficiency is calculated by mechanical output and active power. Finally, the characteristics of efficiency and power factor in three proposed models are compared due to the switching pattern.

  • PDF

Analysis of TV Standby Power for Development of Energy Efficiency Standard (TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석)

  • Kim, Ik-Pyo;Ro, Kyoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.

Total Factor Productivity Growth and the Decomposition Components of Korean Port-Logistics Industry (항만물류산업의 총요소생산성과 그 분해요인분석)

  • Gang, Sang-Mok;Lee, Ju-Byeong
    • Journal of Korea Port Economic Association
    • /
    • v.24 no.4
    • /
    • pp.47-70
    • /
    • 2008
  • The purpose of this study is to estimate total factor productivity(TFP) growth by stochastic frontier function and to grasp contributing factors of its growth rate by decomposing the total factor productivity into efficiency change, technical progress, scale change, and allocation change. Annual growth rate of total factor productivity for 1990-2003 is 0.019 (1.9%), higher than that of overall industry (0.010). The main component of TFP growth is not efficiency change but technical progress. Contributing factors of total factor productivity growth are change of allocation efficiency in port industry, technical progress in sea-transportation industry, and change of scale efficiency in transportation-equipment industry. The change of total factor productivity shows a decreasing trend since late in the 1990s. The annual technical efficiency of port-logistics industry is less than that of overall industry. Capital elasticity for output (0.391) is higher than labor elasticity (0.227), but scale economy of port-logistics industry is 0.618, which is far from optimal scale economy.

  • PDF

A study on the method of manufacturing $TiO_2$ photoelectrode for improving the photocurrent of dye-sensitized solar cells (염료감응형 태양전지 광전류 향상을 위한 $TiO_2$ 광전극 제작방법에 관한 연구)

  • Baek, Hyung-Ryul;Han, Zhen-Ji;Park, Kyung-Hee;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.354-355
    • /
    • 2006
  • We manufactured photoelectrode of dye-sensitized solar cells (DSC) by using three methods such as squeeze method, spray method, and combination method (squeeze method first, spray method second). We examined how the morphology of an electrode's surface, the pore between particles, and condensation have an effect on an open-circuit voltage, photocurrent, fill factor, and energy conversion efficiency. Open-circuit voltage of dye-sensitized solar cells manufactured by using three methods is about 0.66V when the photoelectrode of the three DSCs is about $5{\mu}m$ thick. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using squeeze method is 18.5 and 34 and 7.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using spray method is 3.62 and 62 and 2.8, respectively. Photocurrent and fill factor and conversion efficiency of DSC manufactured by using combination method is 10.7 and 46 and 5.9, respectively. In conclusion, we find that the combination method is better than the other two methods in such respects as energy conversion efficiency and fill factor.

  • PDF