• Title/Summary/Keyword: Effective volume

Search Result 2,423, Processing Time 0.026 seconds

The effect of medium change after pretreating microspores, medium addition, and volume of under solid medium in double layer culture on the production of embryos in isolated microspore culture of hot pepper (Capsicum annuum L.) (고추의 소포자 배양 시 전처리 후 배지의 교환, 배지의 첨가 및 2층배양 시 하층고체 배지의 양이 배의 생산에 미치는 영향)

  • Park, Eun-Joon;Lee, Jong-Suk;An, Dong-Joo;Kim, Moon-Za
    • Journal of Plant Biotechnology
    • /
    • v.37 no.4
    • /
    • pp.494-504
    • /
    • 2010
  • The effect of the addition of the fresh medium, volume of under solid medium in double layer culture as well as the medium change after pretreating microspores on the production of embryos in microspore culture of hot pepper (Capsicum annuum L.) has been studied. When cultured after heat pre-treatment, changing pretreatment media with fresh culture media proved to be more effective for embryo production rather than supplementing additional culture media. Heat-pretreating for 3 days turned out more effective for embryo production than pretreating for 1 or 2 days. In the case of anther pretreatment, the addition of fresh medium after culture was not effective for embryo production. In pretreating microspores, however, supplementing additional fresh culture media greatly improved embryo yield and quality. The best time point of media addition was 4 days after culture commenced, and the most effective number of times of media addition was one time addition. Moreover, the effective volume of added medium in double layer culture for embryo production was 1.5 ml. The addition of media more than 1.5 ml reduced both embryo yield and quality. Double layer medium was more effective for embryo development than liquid medium. When the volume of under solid medium increased ranging from 3 ml to 7 ml, more cotyledonary embryos were produced in either 5 ml or 7 ml compared to 3 ml, even though the total number of embryos were highest in 3 ml. These results can be used as an important data for establishing an efficient microspore culture system for producing high frequency of normal embryos in hot pepper.

Control Method to Ensure Uniform Exhaust Function by Household of Apartment House (공동주택의 세대별 균등 배기량을 확보 하는 제어방법에 관한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.12
    • /
    • pp.628-637
    • /
    • 2017
  • This study was conducted to present an effective control method for the common duct system to uniformly discharge volume flow rate exhausted from the kitchen and bathroom of each household in an apartment regardless of the position of household. Since the common duct system is installed vertically and the ventilator is installed in the terminal, the static pressure of each household decreases when vertical height increases. Therefore, the volume flow rate exhausted from each household is different. In order to improve such a phenomenon, a constant air volume damper shall be installed in a branch duct coupled with a common vertical duct system. The selected ventilator should also be able to handle the maximum volume flow rate considering diversity factor. Therefore, a uniform volume flow rate must be exhausted from all households where the hood is operated. This paper mainly focuses on suggestion of an optimum exhaust control method by comparing exhaust performance of each household according to the presence or absence of a constant air volume damper.

Selective Volume Rendering Using Global Shape Information (전역적 형태정보를 이용한 선택적 볼륨렌더링)

  • Hong, Helen;Kim, Myoung-Hee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.10
    • /
    • pp.3280-3289
    • /
    • 2000
  • In this paper,we propose a novel technoque of improving volume rendering quality and speed by integrating volume data and global shape information together. The selective volume rendering method is to generate distance transformed volume using a distance transform to determine the minimum distance to the neaest intercsting part and then render it. The shape information prevents from object occlusions come from similar intensity of each object. Thus it provides effective visual results that enable to get a clear understanding of complex structures. We show the results of selective volume rendering method for left ventricle and right ventricle ans well as the results of selective sampling methods depending on the interpolation from EBCT cardiac images. Our method offers an accelerated technique to accurately visuahze the surfaces of devined objects segmented from the volume.

  • PDF

A Study on the Correlation Analysis between the Daily Earthwork Volume and Fine Dust Concentration

  • Dong-Myeong, CHO;Ju-Yeon, LEE;Tae-Hwan, JEONG;Woo-Taeg, KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: Fine dust is classified as a group 1 carcinogen and poses a significant environmental problem that urgently requires improvement to protect the environmental rights of citizens. Given the difficulty of implementing measures to reduce overseas sources of fine dust, it is essential to first devise specific measures to address domestic emission sources. As such, this study aims to analyze the correlation between earthwork volume control and fine dust concentration as preliminary management measures to reduce the impact of scattering dust at construction sites. Based on real-time air quality information, field management measures will be presented to mitigate the effects of dust emissions. Research design, data and methodology: As examples, we selected construction sites that had recently undergone small-scale environmental impact assessment consultations. The standard earthwork volume was classified into grades using 20% intervals, and we applied AERMOD to predict the weighted concentration of fine dust based on the earthwork volume class and analyzed its correlation. Results: The results of this study demonstrate a strong correlation between earthwork volume and fine dust concentration. By utilizing the correlation analysis between earthwork volume and fine dust concentration on-site, this finding can be utilized as an effective fine dust management plan. Conclusions: This involves determining the daily earthwork intensity based on real-time air quality information and implementing measures to reduce scattering dust.

A study on the rain attenuation prediction model using effective permittivity (실효유전율을 이용한 강우감쇠 예측 모델에 관한 연구)

  • 김혁제;조삼모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.52-59
    • /
    • 1998
  • We calculated the wave attenuation due to rain using the effective permittivity of the air with raindrops. The effective permittivity depends on the complex permittivity of rain drop and the fractional volume occupied by the raindrops. We calculate the complex permittivity of rain drop and the raindrops' volume using Marshall-Palmer Rain drop size distribution. The rain attenuation calculated by effective permittivity is compared with the results of ITU rain attenuation model, and the two rain attenuation models have a very close agreement. The effetive permittivity model underestimates the rain attenuation under 50 GHz, and overestimate at the frequencies under 50 GHz copmpared with the ITU model.

  • PDF

Effect of Reinforcement of Glass fiber on Auto and Heat polymerized denture base resin (유리 섬유의 첨가에 따른 자가중합 및 열중합 의치상용 레진의 강화효과)

  • Yu, Sang-Hui;Kim, Yeoun-Soo;Choi, Un-Jae;Jun, Jong-Nam
    • Journal of Technologic Dentistry
    • /
    • v.31 no.4
    • /
    • pp.37-43
    • /
    • 2009
  • This study evaluated the effect of concentration of glass fiber reinforcement on the flexural properties of auto and heat polymerized denture base resin. The test specimens($64{\times}10{\times}3.3mm$) were made of auto and heat polymerized resin(Vertex, Dentimax, Netherlands). Glass fiber(ER 270FW, Hankuk Fiber Glass, Korea) were used to reinforce the denture base resin. The 2.6%, 5.3% and 7.9% volume pre-impregnated fiber were located at the bottom of specimen. The test specimens(n=7) of each group were stored in distilled water at $37^{\circ}C$ for 50 hours before test. The flexural strength and modulus were measured by an universal testing machine(Z020, Zwick, Germany) at a crosshead speed of 5 mm/min in a three-point bending mode. The data was analyzed by one-way ANOVA and the Duncan's multiple range test(${\alpha}$=0.05). The difference of auto polymerized resin groups and heat polymerized resin groups were statistically analyzed by t-test(${\alpha}$=0.05). Glass fiber showed significant reinforcing effects on auto and heat polymerized resin. For flexural strength and modulus, auto polymerized resin was the highest in 7.9% volume, while heat polymerized resin was the highest in 5.3% volume. In this study, glass fiber at 7.9% volume ratio showed most effective reinforcing effect on auto polymerized resin and glass fiber at 5.3% volume ratio showed most effective reinforcing effect on heat polymerized resin in terms of flexural strength and flexural modulus.

  • PDF

Factors Affecting Temperature of Urban Parks (도시공원의 기온에 영향을 미치는 요인)

  • 윤용한;송태갑
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.39-48
    • /
    • 2000
  • The purpose of this study is to investigate the factors affecting temperature of urban parks to grasp the relationship between the land coverage in open space as well as the forest condition and decreasing city temperature by difference of purposed are. Futhermore, this research interpreted the relationship between wind direction, air temperature, the land coverage of the green space, the number of tree, green volume, height of tree and the mitigation of city temperature with the revolution analysis. The result of this study is that cool air in open space move leeward and decreasing city temperature is influenced by the difference of the land coverage in open space. Specifically, in order of the arbo $r_{-a}$rbor in the forest zone, the increase of the number of trees was related with temperature surrounding significantly. This study found that the use possibility of the green volume was recognized as the index of the green volume relative to air temperature surrounding. Green space of the city control area is more effective decreasing temperature than that of housing zone.

  • PDF

Scaling methods for wind tunnel modelling of building internal pressures induced through openings

  • Sharma, Rajnish N.;Mason, Simon;Driver, Philip
    • Wind and Structures
    • /
    • v.13 no.4
    • /
    • pp.363-374
    • /
    • 2010
  • Appropriate scaling methods for wind tunnel modelling of building internal pressures induced through a dominant opening were investigated. In particular, model cavity volume distortion and geometric scaling of the opening details were studied. It was found that while model volume distortion may be used to scale down buildings for wind tunnel studies on internal pressure, the implementation of the added volume must be done with care so as not to create two cavity resonance systems. Incorrect scaling of opening details was also found to generate incorrect internal pressure characteristics. Furthermore, the effective air slug or jet was found to be longer when the opening was near a floor or sidewall as evidenced by somewhat lower Helmholtz frequencies. It is also shown that tangential flow excitation of Helmholtz resonance for off-centre openings in normal flow is also possible.

Reach volume의 측정과 로보트 기구학을 이용한 해석적 생성의 비교

  • 기도형;신용탁;강동석;정의승
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.232-237
    • /
    • 1996
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chineses populations, and foot reach and trunk motion have been excluded. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. Therefore, in this research, range of two degrees of reedom motion was measured, in which 47 college students were participated volumtarily as subjects. Second, new approximate algorithms generating reach volumes were suggested based on the robot kinematics, in which range of two degrees of freedom motion was considered. Our analytically generated reach volume showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

FRACTIONAL STEP METHOD COMBINED WITH VOLUME-OF-FLUID METHOD FOR EFFICIENT SIMULATION OF UNSTEADY MULTIPHASE FLOW (비정상 다상유동의 효율적 수치모사를 위한 VOF가 적용된 Fractional Step 기법)

  • Lee, Kyong-Jun;Yang, Kyung-Soo;Kang, Chang-Woo
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.99-108
    • /
    • 2010
  • Fractional Step Methods(FSM) are popular in simulation of unsteady incompressible flow. In this study, we demonstrate that FSM, combined with a Volume-Of-Fluid method, can be further applied to simulation of multiphase flow. The interface between the fluids is constructed by the effective least squares volume-of-fluid interface reconstruction algorithm and advected by the velocity using the operator split advection algorithm. To verify our numerical methodology, our results are compared with other authors' numerical and experimental results for the benchmark problems, revealing excellent agreement. The present FSM sheds light on accurate simulation of turbulent multiphase flow which is found in many engineering applications.