터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여- (A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop-)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제6권1호
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF

흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안 (Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography)

  • 심지나;이영진
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.139-145
    • /
    • 2021
  • 본 연구는 흉부 X-ray 검사 시 디지털 영상의 적절한 유효 Detector exposure index (DEI) 범위 내의 영상의 Dose area product (DAP)값과 유효선량을 비교함으로써 적절한 관전압의 범위를 확인하고자 하였다. GE Definium 8000을 사용하여 흉부팬텀을 이용한 Chest PA 검사를 재현하였다. kVp range는 60~130 kVp, mAs range는 2.5 ~ 40 mAs로 설정하였다. 획득한 영상을 유효한 DEI 범위의 영상으로 분류하고 측정한 DAP을 이용하여 PC-Based Monte Carlo Program을 통해 유효선량을 계산하였다. 영상의 정량적 평가를 하기 위해 Picture archiving and communication system을 이용하여 흉추, 갈비뼈가 포함된 폐야부위, 갈비뼈가 포함되지 않은 폐야부위, 간 등 총 네 부분의 Signal to noise ratio (SNR)를 측정하였다. 관전압 별 그룹의 유의성은 Kruskal-wallis test와 사후검정으로 Mann-whitney test를 시행하여 검증하였으며 검증에 사용된 신뢰구간은 95%이다. 총 13개의 관전압 중 적정한 유효 DEI 범위안에 포함된 네개의 관전압 (60~90 kVp)을 각각 비교하였을 때, DAP는 60 kVp를 기준으로 80 kVp, 90 kVp를 비교한 결과에서만 유의한 차이를 보였다 (p= 0.034, 0.021). 유효선량은 모든 관전압 그룹에서 유의한 차이를 보이지 않았다 (p>0.05). SNR은 간 부위에서 80 kVp와 90 kVp를 제외한 모든 그룹에서 유의한 차이를 보였다 (p<0.05). 그러므로 디지털 환경에서 적정한 흉부 X-ray 영상의 농도를 나타내기 위해 100 kVp 이상의 고관전압은 환자 선량 및 영상 측면에서 재고할 필요성이 있다고 사료된다.

내압을 받는 튜브 리듀싱에 관한 연구 (Study on the Tube Reducing Process Subject to Internal Pressure)

  • 이항수;양동열
    • 한국정밀공학회지
    • /
    • 제4권4호
    • /
    • pp.72-83
    • /
    • 1987
  • In axisymmetric tube reducing process for thin sheet metal tubes, the reduction ration of diameter is an important factor in the process design. For very thin sheet metal tubes, tube reducing cannot be successfully employed due to wrinkling of the edge portion of a tube as well as due to buckling of its rest portion. In the present study, thin sheet metal tubes are subjected to internal pressure during the tube reducing process in order to increase the forming limits. Analysis is made for the sound flow deformation in nonsteady tube reducing considering the normal anisotropy. Experiments are carried out for brass tubes. The present study is shown to give an effective guide line in designing the tube reducing process for very thin-walled sheet metal tubes. Hpwever, it is suggested that an analysis for instability should be made to design the process more effectively.

  • PDF

Experiment of Compressive Strength Enhancement of Circular Concrete Column Confined by Carbon Tubes

  • Hong Won-Kee;Kim Hee-Cheul;Yoon Suk-Han
    • KCI Concrete Journal
    • /
    • 제14권4호
    • /
    • pp.139-144
    • /
    • 2002
  • Concrete filled FRP tube has lately attracted attention as the member that can substitute the conventional reinforced concrete. Glass fiber and carbon fiber are some of available materials for FRP tube. Carbon tube is filament wound with specified winding angle to meet the appropriate capacity demands. Confinement effect of carbon tube is varied according to winding angle. In this study, a total 4 of large scale circular specimens of 30cm diameter and 60cm height is tested. To estimate the effect of winding angle and thickness of carbon tube on the increased confined compressive strength, the test tube are wound with $\pm45^{\circ}\;and\;\pm30^{\circ}$ with two types of thickness, 2mm and 3mm, respectively. It is shown that effectively increased confined strength and ductility are observed from the specimens with $\pm45^{\circ}$ winding angle than $\pm30^{\circ}$ winding angle. Increasing thickness is not as effective as adjusting winding angle for the confinement of concrete core.

  • PDF

관막음된 증기발생기 전열관의 유체유발진동 특성 평가 (Estimation of Flow-induced Vibration Characteristics on Plugged Steam Generator Tube)

  • Cho, Bong-Ho;Ryu, Ki-Wahn;Park, Chi-Yong;Park, Su-Ki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.390.1-390
    • /
    • 2002
  • In this study, we investigate the plugging effect on the CE type steam generator tube. The natural frequency and mode shape will be changed due to decrease of the effective mass distribution along the tube. We compared the variation of stability ratio for plugged tube with that fur unplugged one. The natural frequency increased because of removing the cooling water inside the steam generator tube, but the stability ratio decreased inversely because of changing the vibrational mode shape. We also investigated the turbulent excitation effect.

  • PDF

축하중을 받는 콘크리트 충전 탄소섬유튜브 기둥의 소성 이론을 적용한 비선형 유한요소해석 (Nonlinear finite element analysis of Concrete Filled Carbon Tube Columns Using Plasticity Theory)

  • 김희철;서상훈;이영학
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.119-126
    • /
    • 2007
  • In the field of composite structures, the use of carbon tube for the confinement of concrete has been arisen since 1990's. However, experimental and analytical studies were limited to those of reinforced concrete and concrete filled steel tube. The carbon tube provides excellent confinement capabilities for concrete cores, enhancing compressive strength and ductility of concrete significantly. The carbon tube has high tensile strength, light weight, corrosion immunity and high fatigue strength properties. Since carbon fiber is an anisotropic material, carbon tube could be optimized by adjusting the fiber orientation, thickness and the number of different layers. In this study, both experimental and analytical studies of axial and lateral behavior of full-scale CFCT (Concrete Filled Carbon Tube) columns subjected to monotonic axial load were carried out using Drucker-Prager theory. And, based on comparison results between experiment results and analytical results, k factor estimation was proposed for effective analysis.

튜브 직경에 따른 과냉각 유동 내 단일 기포 응축의 영향 (Effect of a Tube Diameter on Single Bubble Condensation in Subcooled Flow)

  • 이선엽;;이재화
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.47-56
    • /
    • 2023
  • Bubble condensation, which involves the interaction of bubbles within the subcooled liquid flow, plays an important role in the effective control of thermal devices. In this study, numerical simulations are performed using a VOF (Volume of Fluid) model to investigate the effect of tube diameter on bubble condensation. As the tube diameter decreases, condensation bubbles persist for a long time and disappear at a higher position. It is observed that for small tube diameters, the heat transfer coefficients of condensation bubbles, which is a quantitative parameter of condensation rate, are smaller than those for large tube diameters. When the tube diameter is small, the subcooled liquid around the condensing bubble is locally participated in the condensation of the bubble to fill the reduced volume of the bubble due to the generation of a backflow in the narrow space between the bubble and the wall, so that the heat transfer coefficient decreases.

가정용 보일러의 급탕시설 개선방안에 관한 연구 (A Study on the Improvement of the Water System in Domestic Boiler)

  • 한규일;박종운
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.200-211
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

핵비등 촉진 전열면 증발부를 이용한 고성능 Bubble Jet Loop Heat Pipe 개발 (Development of a High Performance Bubble Jet Loop Heat Pipe Using the Enhanced Nucleate Boiling Surface in Evaporating Section)

  • 김종수;신종석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.363-367
    • /
    • 2015
  • 본 연구는, 증발부에 핵비등 전열 촉진면을 사용하여 수평상태에서도 작동 가능한 고성능 버블젯 루프 히트파이프(BJLHP)의 개발에 관한 것이다. 비등 촉진 전열면은 소결관과 GEWA-T 전열관을 사용하였으며, 평활관을 사용한 BJLHP와 유효열전도도를 사용하여 열성능을 비교, 검토하였다. 작동유체로는 R-141b를 사용하였으며, 충전량은 BJLHP 내부 체적의 50%, 입열량은 75W와 100W로 하였다. 그 결과 소결관을 사용한 BJLHP의 열성능이 가장 우수한 것으로 나타났으며, 소결관을 사용한 BJLHP의 유효열전도도가 평활관 BJLHP보다 300% 이상 향상되었다.

Local and Overall Heat Transfer Characteristics of Fin- Flat Tube Heat Exchanger with Vortex Generators

  • Yoo, Seong-Yeon;Chung, Min-Ho;Park, Dong-Seong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.150-157
    • /
    • 2003
  • Local and overall heat transfer characteristics of fin-flat tube heat exchangers with and without vortex generators were investigated. Local heat transfer coefficients were measured with the heat exchanger model using naphthalene sublimation technique. In case of a fin-flat tube heat exchanger without vortex generators, only the horseshoe vortices formed around tubes augment the heat transfer. On the other hand, longitudinal vortices created artificially by vortex generators additionally enhance heat transfer in case of a fin-flat tube heat exchanger with vortex generators. Overall heat transfer coefficients were measured with the prototypes of the fin-flat tube heat exchanger with and without vortex generators in a wind tunnel and results were compared with those of a fin-circular tube heat exchanger with wavy fin. Friction losses for heat exchangers were also measured and compared. The fin-flat tube heat exchanger with vortex generators is found to be more effective than the fin-circular tube heat exchanger with wavy fin.