• 제목/요약/키워드: Effective removal rate

Search Result 540, Processing Time 0.025 seconds

Study on the Activation of Microbial Products by Using the Leachate (침출수를 이용한 미생물 제제의 활성에 관한 연구)

  • 이장훈;정준오;남명흔
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.70-76
    • /
    • 1998
  • Activation bacteria, identified from commercial microbial products, were applied to leachate treatment. Total seven strains of bacteria Enterobacteriaceae spp. (5), Bacillus sp. (1), Aeromonas sp. (1) were seeded in the leachate and cultured in the shaking incubator at 25$^{\circ}$C and 250 rpm. While cultured, they were sampled in given time intervals and the removal rates of SS, COD, BOD, T-N.and T-P were measured an indicators of leachate treatment. Through the screening test, four of 7 strains of bacteria were considered to be effective and they were named as "effective group". The capability of leachate treatment was observed on three different groups of bacteria single, effctive, and total mixed. The result showed that the removal rates of COD and SS for the total mixed group were 64 and 71% respectively. BOD removal rate was reached nearly 99% by seeding of effective griup and removal rates of T-P and T-N were 83 and 82% respectively. However seeding of single strain was less effective than that of any mixed group in leachate treatment.

  • PDF

고정화 질화세균을 이용한 저농도 암모니아의 고도처리 (II) 초기 암모니아 농도, 온도 그리고 pH의 영향

  • Lee, Jeong-Hun;Kim, Byeong-Jin;Lee, Min-Su;Na, In-Geol;Seo, Geun-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.346-348
    • /
    • 2002
  • This study estimated the effect of influent TAN concentration. temperature and pH in the airlift bioreactor(aeration rate; 1.5 vvm, HRT 0.35hr) using immobilized nitrifiers by PVA. At the effect of influent TAN concentration, removal rate was increased with increasing it and removal efficiency maintained 93${\pm}$2%. The optimum temperature for nitrification was $30^{\circ}C$ and at this point. removal efficiency was 95.5${\pm}$1.5%. It was effective to nitrify at $10^{\circ}C$ of low temperature. In the pH range from 7 to 9 in the bioreactor. removal rate and removal efficiency was 310${\pm}$10 $g/m^3$ day and 94${\pm}$3%.

  • PDF

Application of SMBR process in food wastewater advanced treatment (SMBR을 이용한 음식폐수의 고도처리)

  • 윤용수;강광남;정순형
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Submerged Membrane Bio-Reacter(SMBR) process was used to food wastewater treatment. From laboratory pilot-scale experiment data, it was confirmed that this process was very effective process for organics, suspended solid, and N, P treatment. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 150 days operation. Organics loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained. IN the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 95%, respectively. It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

Removal of Total Suspended Solids by a Foam Fractionator in a Simulated Seawater Aquaculture System

  • Peng, Lei;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.216-222
    • /
    • 2003
  • In a simulated seawater aquaculture system, effects of different operating factors like the superficial air velocity (SAY), hydraulic residence time (HRT), protein concentration and foam overflow height on the removal of total suspended solids (TSS) by a foam fractionator, with 20 cm diameter and 120 cm height, were investigated. This experiment was performed on batch and consecutive modes for different combinations of the tested factors, using synthetic wastewater. In 5 consecutive trials, TSS concentration in culture tank water decreased faster, when the foam fractionator was operated at higher SAV and lower HRT. In batch trials, with increasing SAV, TSS removal rate increased, but decreased with increasing HRT. Higher protein concentration in the bulk solution resulted in higher TSS removal rate. TSS concentration in the collected foam condensates increased but the foam overflow rate decreased with increasing foam overflow height. Foam fractionation was effective for removing TSS in seawater aquaculture systems and its performance largely depended on the operating parameters, especially superficial air velocity.

NC Code Post-Processor Considering Metal Removal Rate (절삭부하 예측을 통한 NC코드 후처리시스템)

  • 이기우;노상도;신동목;한형상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.116-123
    • /
    • 2000
  • This paper presents an NC code post-processor that adjusts feedrates to keep the variation of metal removal rate along the tool paths minimum. Metal removal rate is estimated by virtually machining the part, whose surface model is built from a series of NC codes defined in operation plan, with cutting-tool-assembly models, whose geometry are defined in a machining database. The NC code post-processor modifies the feedrates by the adjustment rules, which are based on the machining knowledge for effective machining. This paper illustrates a procedure fur grouping machining conditions and we also show how to determine an adjustment rule for a machining-condition group. An example part was machined and it shows that the variation of cutting force was dramatically reduced after applying the NC code post-processor. The NC code post-processor is expected to increase productivity while maintaining the quality of the machined part.

  • PDF

Crosslinking of $\beta$-Cyclodextrin on Cholesterol Removal from Milk

  • Kim, S.H.;Ahn, J.;Kwak, H.S.
    • Archives of Pharmacal Research
    • /
    • v.27 no.11
    • /
    • pp.1183-1187
    • /
    • 2004
  • This study was designed to develop crosslinking of $\beta$-cyclodextrin ($\beta$-CD), and determine the optimum conditions of different factors (mixing time, mixing temperature, and mixing speed) on cholesterol reduction from milk. Crosslinked $\beta$-CD was prepared with epichlorohydrin. When milk was treated with different conditions, the cholesterol removal rate was in the range of 79.4 to 83.3% with 1 % crosslinked $\beta$-CD addition, which were not significantly different among treatments. After cholesterol removal from milk, the used crosslinked $\beta$-CD was washed for cholesterol dissociation and reused. For recycling study, the cholesterol removal rate in first trial was 81.8%, which was mostly same as that using new crosslinked $\beta$-CD. With five trials repeatedly using the same sample, the mean cholesterol removal rate was 81.2%. The present study indicated that the optimum conditions on cholesterol removal using crosslinked $\beta$-CD were 10 min mixing with 400 rpm speed at $5^{\circ}C$ with about 80% cholesterol removal. In addition, crosslinked $\beta$-CD resulted in the effective recycling efficiency almost 100%.

Feasibility Study of Intermittent Slow Sand Filtration for Agricultural Reuse of Reclaimed Water (농업적 용수재이용을 위한 간헐분사 완속모래여과 하수재처리 효율 평가)

  • 윤춘경;정광욱;함종화;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.160-170
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of intermittent slow sand filtration for agricultural reuse of reclaimed water. The effluent of biofilter for 16-unit apartment was used as influent to the slow sand filtration system at 0.6 $m^3$/day loading rate using 15 seconds spray in every 10 minutes on the about 1 $m^2$ surface area and 0.5 m depth. The influent concentrations of total coliform (TC), fecal coliform (FC) and E. coli were in the range of 10.000 MPN/100 mL. and they were reduced to less than 1,000 MPN/100 mL after filtration with average of 320, 270, and 154 MPN/100 mL, respectively, showing over 95 % removal. Turbidity and SS were improved effectively and their average concentration was reduced to 0.8 NTU and 1.7 mg/L, respectively, and removal rate was about 50 %. Average BOD and COD concentrations were also reduced substantially to 2.6 and 25.8 mg/L with about 55 and 21 % removal rate, respectively. Nutrients removal was relatively low and removal rate for T-N and T-P was low however, remaining nutrients might be beneficial and less concerned in case of agricultural reuse. The concentration of biofilter effluent used in this experiment was in the range of secondary treatment effluent but slightly stronger than the one from existing wastewater treatment plants (WWTPs). Therefore, intermittent slow sand filtration might be also applicable to the effluent from WWTPs as long as its agricultural reuse is available. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, the intermittent slow sand filtration was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper is a preliminary result from pilot study and further investigations are recommended on the optimum design parameters before full scale application.

A Study on apply of submerged biofilter for nutrient removal (영양염류 제거를 위한 생물막 공정의 적용에 관한 연구)

  • 안승섭
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.415-422
    • /
    • 2000
  • In this study the removal possibility of nutrients of T-P, NH3-N, NO3-N and T-N is examined through a positive experimental study using submerged biofilter of media packing channel method. From the analysis of nutrients removal efficiency for each run of the collected sample following results are obtained. Firstly the result of N/P surveying for inflow shows serious value that excess the limit value of 20 as the values are in the range of 12.0~42.7 and the average is 25.73. Secondly the highest concentration of the incoming NH3-N reaches double of the standard since the concentrations of NH3-N and NO3-N for inflow shows 0.06mg/$\ell$ and 2.5~3.8mg/$\ell$ respectively and the average removal rate which passed the submerged biofilter adopted in this study is a satisfactory level. Next the average removal rate of T-P of 51.5% shows the possiblity of entrophication removal since the removal rate of T-P of 66.8~68.8% in relative low temperature period of RUN 1~2 appeared higher than in RUN 3~6 and T-N shows relatively poor result with the average removal rate of 34.1% And it is known that the bigger BOD/P and BOD/N are the more removal rate increases from the examination result of the relation between BOD/P and BOD/N and the treatment water T-P and T-N to decide the relation with the concentration of organic matters and though that the appropriate proportion is necessary for effective removal of nitrogen and phsophorus.

  • PDF

Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors (공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구)

  • Kim, Jin-Ki;Yu, Sung-Whan;Lim, Bong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

Development of Up- and Down-flow Constructed Wetland for Advanced Wastewater Treatment in Rural Communities (소규모 오수발생지역의 고도처리시설을 위한 상.하 흐름형 인공습지 개발)

  • Kim, Hyung-Joong;Yoon, Chun-G.;Kwun, Tae-Young;Jung, Kwang-Wook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.113-124
    • /
    • 2006
  • The feasibility of the up- and down-flow constructed wetland was examined fur rural wastewater treatment in Korea. Many constructed wetland process was suffered from substrate clogging and high plant stresses because of long term operation. The up- and down-flow constructed wetland process used porous granule materials (charcoal pumice : SSR=10:20:70) for promoting intake rate of nutrient to plant, and especially flow type was designed continuously repeating from up-flow to down-flow. $BOD_5$ and SS was removed effectively by the process with the average removal rate being about 75% respectively. The wetland process was effective in treating nutrient as well as organic pollutant. Removal of TN and TP were more effective than other wetland system and mean effluent concentrations were approximately 7.5 and $0.4mg\;L^{-1}$ which satisfied the water quality standard for WWTPs. The treatment system did not experience any clogging or accumulations of pollutants and reduction of treatment efficiency during winter period because constructed polycarbonate glass structure prevented temperature drop. Considering stable performance and effective removal of pollutant in wastewater, low maintenance, and cost-effectiveness, the up- and down-flow constructed wetland was thought to be an effective and feasible alternative in rural area.