• Title/Summary/Keyword: Effective Impedance

Search Result 365, Processing Time 0.031 seconds

Characteristic Analysis of a Flux-Lock Type SFCL Considering Magnetization Characteristic of Iron Core (철심의 자화특성을 고려한 자속구속형 초전도 사고전류제한기의 특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.995-999
    • /
    • 2007
  • We investigated the characteristics of a flux-lock type superconducting fault current limiter(SFCL) considering magnetization characteristic of iron core. The flux-lock type SFCL, like other types of SFCLs using the iron core, undergoes the saturation of the iron core during the initial fault time. Therefore, if the design to prevent the saturation of the iron core is considered, the effective fault current limiting operation can be achieved. Through the analysis for its equivalent circuit including the magnetization characteristic of the iron core, the limiting impedance of the flux-lock type SFCL was drawn. The magnetization currents and the limited currents of SFCL, which were dependent on the winding direction and the turns' ratio between two coils, were investigated from the short circuit experiment. It was confirmed that their experimental results agreed with the analysis ones.

Measurement of Acoustic Properties and Prediction of Acoustic Performance of Porous Woven Hoses for Engine Intake Systems (엔진 흡기계에 쓰이는 다공형 직조관의 음향특성 측정 및 성능예측)

  • Park, C.M.;Ih, J.G.;Nakayama, Y.;Kitahara, S.;Takao, H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.182-186
    • /
    • 2000
  • The porous woven hose is recently considered as an effective element of automotive intake systems. In order to predict the acoustic performance of an intake system with a porous woven hose, the information on the acoustic wall impedance is required. In this article, a measurement technique that is valid over the low frequency range and without mean flow condition is presented. The measurement is performed in a cylindrical chamber with a concentric layout of the sample and the resistance is estimated from measured reactance and transmission loss data. It is observed that the measured transmission loss for a porous woven hose with an arbitrary length agrees well with the predicted one that uses the estimated impedance for a small sample length.

  • PDF

Ferrite-based wideband circularly polarized microstrip antenna design

  • Mashhadi, Mostafa;Komjani, Nader;Rejaei, Behzad;Ghalibafan, Javad
    • ETRI Journal
    • /
    • v.41 no.3
    • /
    • pp.289-297
    • /
    • 2019
  • In this paper, a wideband, circularly polarized patch antenna is proposed that leverages the unidirectional resonant modes of a circular patch mounted on top of a grounded dielectric-ferrite substrate. The proposed antenna is fed via the proximity coupling method and several parasitically coupled patches are placed on a dielectric superstrate to enhance the impedance bandwidth of the antenna. The resonant modes of the structure rotate only in the clockwise or counter clockwise directions. In the frequency range where the effective permeability of the ferrite layer is negative, the resonance frequencies of these modes differ significantly, which produces a large axial ratio (AR) bandwidth. For the proposed antenna, the numerical results show the 10 dB impedance bandwidth to be around 44% and the 3 dB axial ratio bandwidth to be higher than 64%.

Switched Capacitor Based High Gain DC-DC Converter Topology for Multiple Voltage Conversion Ratios with Reduced Output Impedance

  • Priyadarshi, Anurag;Kar, Pratik Kumar;Karanki, Srinivas Bhaskar
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.676-690
    • /
    • 2019
  • This paper presents a switched capacitor (SC) based bidirectional dc-dc converter topology for high voltage gain applications. The proposed converter is able to operate with multiple integral voltage conversion ratios based on user input. The architecture of a user-friendly, inductor-less multi-voltage-gain bidirectional dc-dc converter is proposed in this study. The inductor-less or magnetic-less design of the proposed converter makes it effective in higher temperature applications. Furthermore, the proposed converter has a reduced component count and lower voltage stress across its switches and capacitors when compared to existing SC converters. An output impedance analysis of the proposed converter is presented and compared with popular existing SC converters. The proposed converter is simulated in the OrCAD PSpice environment and the obtained results are presented. A 200 W hardware prototype of the proposed SC converter has been developed. Experimental results are presented to validate the efficacy of the proposed converter.

The influences of sex on the human emotions toward robots

  • Ben-Lamine, Mohamed-Sahbi;Shibata, Satoru;Kanya, Tanaka;Shimizu, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.191-194
    • /
    • 1995
  • This paper evaluates the influences of sex on the human emotions while coexisting with robots. When we consider human vision, robot's motion is the most important parameter which influences human emotions and must be well controlled for males and females emotions. On the other hand, when we consider human touch of sense, which is effective for cooperation transmitting mutual forces, the softness of robot is an important parameter for human emotions and must be also well controlled for males and females emotions. From these points of view, at first, we evaluate robot's motion under four different shapes of velocity pattern while handing over a cup to humans. Second, we evaluate robot's softness realized by impedance control. From the first experiment, we concluded that the conditions of choosing an adequate maximum velocity value and locating the velocity peak at the center or the first half of the duration are necessary for male's emotions. In addition, the smooth velocity decrease in the last part of the velocity pattern's duration is desired for female's emotions. From the second experiment, we concluded that females prefer lighter values of virtual impedance characteristics than males and any small increase on the heaviness of virtual impedance values is followed by the negative exponential change on human emotions.

  • PDF

Early Detection of Infiltration Induced in the Veins of Pig's Ear and Human's Forearm By Using Bioimpedance: Pilot Study

  • Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Jeong, Ihn Sook;Jeon, Gyerok
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.1
    • /
    • pp.34-44
    • /
    • 2018
  • An early detection of intravenous (IV) infiltration is essential to minimize the injuries during infusion therapy, which is one of the most important tasks for nurses in nursing settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a pig's posterior ear, impedance parameters (R, $X_C$, $C_m$) showed significant differences before and after infiltration. In particular, the relative resistance ($R/R_{BI}$) decreased significantly at infiltration and then slowly decreased. This indicates that the vein in pig's ear is thin and the amount of surrounding subcutaneous tissue, and hence the infiltrated solution accumulates slowly after infiltration. However, when infiltration was induced in the vein of human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_C$ graph, the positions in the case of infiltration induced in the pig' ear shifted rapidly before and after infiltration, whereas the positions in the case of infiltration induced in the human's forearm moved gradually during infiltration. Our findings suggest that the impedance parameters (R, $R/R_{BI}$, $X_C$, R vs. $X_C$, and $C_m$) are effective indicators to detect the infiltration early in a non-invasive and quantitative manners.

Development and Verification of a Hand-held Typed Monitoring System for Cardiac Output Measurement using Electrical Impedance Technique (전기적 임피던스 방법을 통한 hand-held 타입의 심박출량 모니터링 시스템 개발 및 검증)

  • Seo, Kwang-Seok;Sim, Myeong-Heon;Kim, Min-Yong;Yoon, Chan-Sol;Chung, Joo-Hong;Park, Sung-Bin;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1932-1938
    • /
    • 2012
  • The impedance cardiogram has been proposed as a non-invasive, continuous, operator independent, and cost-effective method for cardiac output monitoring. However, it can not be completely considered as non-restrictive method because of attached spot and band type electrodes. Therefore, we developed a improved convenient hand-held typed measurement system for cardiac output by electrical impedance technique. 80 subjects from Yonsei University and the surrounding areas, participated. All subjects measured stroke volume and cardiac output through Physioflow and developed system. To verify the developed system, statistical methods such as correlation, Wilcoxon signed ranks test, and the Bland-Altman analysis were used. The proposed system showed significant correlation in both male and female stroke volume(r=0.715, r=0.704) and cardiac output(r=0.826; r=0.804). From these results, it can be concluded that stroke volume and cardiac output could be improved convenient measurement using the both hands without the help of a specialist.

An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems

  • Min, Jiyoung;Yun, Chung-Bang;Hong, Jung-Wuk
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.107-122
    • /
    • 2016
  • We propose an effective methodology using electromechanical impedance characteristics for estimating the remaining tensile force of tendons and simultaneously detecting damages of the anchorage blocks. Once one piezoelectric patch is attached on the anchor head and the other is bonded on the bearing plate, impedance responses are measured through these two patches under varying tensile force conditions. Then statistical indices are calculated from the impedances, and two types of relationship curves between the tensile force and the statistical index (TE Curve) and between statistical indices of two patches (SR Curve) are established. Those are considered as database for monitoring both the tendon and the anchorage system. If damage exists on the bearing plate, the statistical index of patch on the bearing plate would be out of bounds of the SR curve and damage can be detected. A change in the statistical index by damage is calibrated with the SR curve, and the tensile force can be estimated with the corrected index and the TE Curve. For validation of the developed methodology, experimental studies are performed on the scaled model of an anchorage system that is simplified only with 3 solid wedges, a 3-hole anchor head, and a bearing plate. Then, the methodology is applied to a real scale anchorage system that has 19 strands, wedges, an anchor head, a bearing plate, and a steel duct. It is observed that the proposed scheme gives quite accurate estimation of the remaining tensile forces. Therefore, this methodology has great potential for practical use to evaluate the remaining tensile forces and damage status in the post-tensioned structural members.

Study of Harmonic Suppression of Ship Electric Propulsion Systems

  • Wang, Yifei;Yuan, Youxin;Chen, Jing
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1303-1314
    • /
    • 2019
  • This paper studies the harmonic characteristics of ship electric propulsion systems and their treatment methods. It also adopts effective measures to suppress and prevent ship power systems from affecting ship operation due to the serious damage caused by harmonics. Firstly, the harmonic characteristics of a ship electric propulsion system are reviewed and discussed. Secondly, aiming at problems such as resonant frequency and filter characteristics variations, resonance point migration, and unstable filtering performances in conventional passive filters, a method for fully tuning of a passive dynamic tunable filter (PDTF) is proposed to realize harmonic suppression. Thirdly, to address the problems of the uncontrollable inductance L of traditional air gap iron core reactors and the harmonics of power electronic impedance converters (PEICs), this paper proposes an electromagnetic coupling reactor with impedance transformation and harmonic suppression characteristics (ECRITHS), with the internal filter (IF) designed to suppress the harmonics generated by PEICs. The ECRITHS is characterized by both harmonic suppression and impedance change. Fourthly, the ECRITHS is investigated. This investigation includes the harmonic suppression characteristics and impedance transformation characteristics of the ECRITHS at the fundamental frequency, which shows the good performance of the ECRITHS. Simulation and experimental evaluations of the PDTF are carried out. Multiple PDTFs can be configured to realize multi-order simultaneous dynamic filtering, and can effectively eliminate the current harmonics of ship electric propulsion systems. This is done to reduce the total harmonic distortion (THD) of the supply currents to well below the 5% limit imposed by the IEEE-519 standard. The PDTF also can eliminate harmonic currents in different geographic places by using a low voltage distribution system. Finally, a detailed discussion is presented, with challenges and future implications discussed. The research results are intended to effectively eliminate the harmonics of ship electric power propulsion systems and to improve the power quality of ship power systems. This is of theoretical and practical significance for improving the power quality and power savings of ship power systems.

Effective Installation Methods of Down Conductors in Lightning Protection Systems (뇌보호시스템에서 인하도선의 효과적인 설치기법)

  • 이복희;엄주홍;이승칠;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.8-14
    • /
    • 2002
  • A modern lightning protection system is required to eliminate the risks such as electrical shocks and damages of structures, electrical and electronic equipments due to lightning. However, the conventional lightning protection systems play and important role in protecting persons and structures only. Thus an effective lightning protection system is indispensable today in computer, information and communication facilities and etc. The mafor objective of this paper is to develop the technology to protect electronics and computerized facilities against lightning-caused overvoltages. The study is oriented on the control of the potential rise of down conductors with the type and installation method of down conductors. As a result, to reduce side flashes and hazards caused by the potential rise of down conductor due to lightning current, the coaxial cable with a low characteristic impedance and high insulation level is suitable for a down conductor. In particular it is extremely effective to bond down conductors to the steel supporter, metal raceways and steel frame of structures.