3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가 (Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning)

  • 정기정;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가 (Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination)

  • 조용인;김정훈
    • 한국방사선학회논문지
    • /
    • 제14권2호
    • /
    • pp.169-178
    • /
    • 2020
  • 국민의 의료수준 향상으로 CT 검사건수는 매년 증가되고 있는 추세이며, 이에 따라 연간 의료 방사선에 의한 피폭선량 또한 증가되고 있다. 이에 본 연구에서는 CT 부위별 검사 시 노출되는 인체의 유효선량을 평가하고, 이로 인한 생애 암 귀속 위험도를 추정하고자 한다. 첫 번째로, CT 진단참고수준 가이드라인에서 제시하는 부위 중 5가지를 선정하였으며, CT 장치를 통해 각 검사 부위별로 노출되는 인체의 유효선량을 평가하였다. 두 번째로, 동일한 조건 내 ALARA-CT 프로그램을 이용하여 인체 장기 및 유효선량을 산정하였으며, 국내 DRL 수준과 비교하여 검사 프로토콜에 대한 적정성을 평가하였다. 세 번째로, CT 검사 시 노출되는 유효선량에 의한 생애 암 귀속 위험도(LAR)을 추정하였다. 그 결과, 검사 중 복부 다중시기 검사 시 21.18 mSv로 가장 높은 유효선량을 나타내었으며, 복부검사를 제외한 나머지 검사에서는 DRL 이하의 선량수준을 나타내었다. 동일한 조건 내 선량계산 프로그램을 이용한 유효선량 평가 결과, 각 검사별로 약 1.1 ~ 1.9배 이상 높은 결과를 나타내었으며, 장기선량의 경우 검사 부위에 근접한 장기일수록 산란선에 의해 높은 영향을 나타내었다. CT 검사 시 성인의 생애 암 귀속 위험도의 경우, 연령이 증가함에 따라 점차적으로 감소되는 양상을 보였으며, 성별에 따라 다소 상이한 결과를 나타내었다.

소아 CT 촬영시 방사선 피폭과 저감화 방법 (Medical Radiation Exposure in Children CT and Dose Reduction)

  • 이정근;장성주;장영일
    • 한국콘텐츠학회논문지
    • /
    • 제14권1호
    • /
    • pp.356-363
    • /
    • 2014
  • 소아 CT 촬영시 피폭선량을 저감시킬 수 있는 조건을 찾기 위하여 pediatric phantom을 이용하여 소아 방사선량을 비교 분석하였다. 관전류변동제어(tube current modulation:TCM) 방식과 low dose CT protocol(LDCTP)에 따라 소아 검사를 시행하였으며, 검사는 brain, chest, abdomen-pelvis 부위를 전산화 단층촬영 장치를 이용한 3개의 검사 프로토콜을 사용하였다. 거의 모든 MDCT 장치는 volume CT dose index(CTDIvol), dose length product(DLP)와 유효선량 평가 결과를 기록, 보관하고 있으며, 이러한 정보들은 환자들의 방사선 노출 및 위험도를 평가하는 데 필수적이다. 방사선 노출 위험도를 감소시키기 위해서 적정화 및 정당화 원칙을 반드시 준수해야 한다. 관전압(kV)에 따른 TCM 방식을 사용하였을 경우 kV가 낮아질수록 유효선량이 낮아지는 경향을 나타내었으며, low dose CT protocol을 사용한 경우가 유효선량이 상대적으로 더 적은 것을 알 수 있었다. 또한 평균 유효선량은 brain, chest, abdomen-pelvis CT의 결과가 독일의 reference dose 보다 각각 47%, 13.8%, 25.7%로 더 낮게 나타났고. 영국의 reference dose와 비교해도 55.7%, 10.2%, 43.6%에 불과했다. 결론적으로 선량 감소를 위해 주의할 것은 body-weight based tube current adaption을 포함한 TCM, 그리고 LDCTP 등 모든 선량 감소 방안을 이용하여야 한다.

ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가 (A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography)

  • 한원정
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구 (A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient)

  • 이현용;조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구 (Study on Development of Patient Effective Dose Calculation Program of Nuclear Medicine Examination)

  • 선종률;길종원
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.657-665
    • /
    • 2017
  • 본 연구의 목적은 핵의학검사를 하는 수검자(환자)의 유효선량(mSv)을 손쉽게 산출할 수 있는 전용 프로그램을 제작 보급하여 핵의학검사의 피폭선량 연구와 선량정보 공개를 위해 조력하고자 한다. 프로그램은 ICRP 80, 106 Report와 추록4에 수록되어 있는 방사성의약품의 방사능당 유효선량(mSv/MBq)을 Database로 만든 다음 5가지(Area, Clark, Solomon(Fried), Webster, Young) 소아주입량 산출법과 7가지 체표면적 산출법이 적용되도록 Microsoft의 Visual Basic(In Excel)으로 제작하였다. 프로그램은 수검자의 연령, 방사성핵종, 표지화합물, 그리고 인체주입량을 입력하면 유효선량(mSv)이 산출된다. 소아의 경우 연령 입력 시 소아산출법이 활성화 되며 적용할 소아산출법을 선택하면 된다. 그리고 소아산출법 중 Area법을 선택하는 경우 체표면적산출법을 고르는 선택창이 활성화 된다. 그런 다음 성인의 주입량을 입력하면 소아의 주입량과 유효선량(mSv)이 자동으로 산출된다. 본 연구에서 제작한 핵의학검사의 환자 유효선량 계산 프로그램은 실제 계측선량이 아니지만 핵의학 검사 시 받게 되는 인체의 내부피폭선량을 가장 근접하게 산출할 수 있는 도구로서 의미가 있다. 향후 프로그램의 활용도를 높이기 위해 모바일기기에서 사용할 수 있는 애플리케이션으로 제작하여 일반인도 쉽게 접근할 수 있도록 할 것이다.

두부규격방사선사진 촬영시 주요 장기의 등가선량, 유효선량 및 위험도 (EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM CEPHALOMETRIC RADIOGRAPHY TO CRITICAL ORGANS)

  • 강성숙;조봉혜;김현자
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.309-318
    • /
    • 1995
  • In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites(18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The results were as follows: 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland(3.6pSv) and the next highest dose was that received by the bone marrow(3pSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland(2pSv) and the next highest dose was that received by the bone marrow(1.8pSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland(31A p Sv) and the next highest dose was that received by the salivary gland(13.3 p Sv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were $0.72{\times}10^{-6}$, $0.49{\times}10^{-6}$ and $3.51{\times}10^{-6}$, respectively

  • PDF

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산 (A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center)

  • 이창우;이정호
    • Journal of Radiation Protection and Research
    • /
    • 제15권2호
    • /
    • pp.75-85
    • /
    • 1990
  • Kalsruhe원자력 연구소(KfK) 주변의 방사능 측정자료로부터 피폭선량을 계산하였다. 식물성 식품의 섭취가 가장 중요한 피폭 경로였고, 식품중의 자연방사성 동위원소인 K-40 과 Pb-210이 주요 피폭원이었다. 인공방사능에의한 피폭은 대부분 지표에 침척된 Cs-134 와 Cs-137으로부터 방출되는 감마선 때문이었다. KfK주변환경에서의 유효선량당량은 ICRP의 권고제한치보다 훨씬 적은 값이었다.

  • PDF