• Title/Summary/Keyword: Eddy-current

Search Result 1,090, Processing Time 0.029 seconds

LARGE-SCALE VERSUS EDDY EFFECTS CONTROLLING THE INTERANNUAL VARIATION OF MIXED LAYER TEMPERATURE OVER THE NINO3 REGION

  • Kim, Seung-Bum;Lee, Tong;Fukumori, Ichiro
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.21-24
    • /
    • 2006
  • Processes controlling the interannual variation of mixed layer temperature (MLT) averaged over the NINO3 domain ($150-90^{\circ}W$, $5^{\circ}N-5^{\circ}S$) are studied using an ocean data assimilation product that covers the period of 1993 to 2003. Advective tendencies are estimated here as the temperature fluxes through the domain's boundaries, with the boundary temperature referenced to the domain-averaged temperature to remove the dependence on temperature scale. The overall balance is such that surface heat flux opposes the MLT change but horizontal advection and subsurface processes assist the change. The zonal advective tendency is caused primarily by large-scale advection of warm-pool water through the western boundary of the domain. The meridional advective tendency is contributed mostly by Ekman current advecting large-scale temperature anomalies though the southern boundary of the domain. Unlike many previous studies, we explicitly evaluate the subsurface processes that consist of vertical mixing and entrainment. In particular, a rigorous method to estimate entrainment allows an exact budget closure. The vertical mixing across the mixed layer (ML) base has a contribution in phase with the MLT change. The entrainment tendency due to temporal change in ML depth is negligible comparing to other subsurface processes. The entrainment tendency by vertical advection across the ML base is dominated by large-scale changes in wind-driven upwelling and temperature of upwelling water. Tropical instability waves (TIWs) result in smaller-scale vertical advection that warms the domain during La Ni? cooling events. When the advective tendencies are evaluated by spatially averaging the conventional local advective tendencies of temperature, the apparent effects of currents with spatial scales smaller than the domain (such as TIWs) become very important as they redistribute heat within the NINO3 domain. However, such internal redistribution of heat does not represent external processes that control the domain-averaged MLT.

  • PDF

Analysis of Properties of Flake Sendust EM Wave Absorber according to Granularity (입도에 따른 Flake Sendust 전파 흡수체의 특성 분석)

  • Park, Soo-Hoon;Kim, Dong-Il;Choi, Dong-Han;Kim, Seong-Yeon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1051-1057
    • /
    • 2008
  • In this paper, we analyzed the characteristics of the EM wave absorber which was fabricated by using flake sendust (soft metal magnetic powder). The flake sendust was made of 3 different granularity by attrition mill. First, we have fabricated 3 kind of EM wave absorbers using the flake sendust and CPE(Chlorinated Polyethylene) and measured the S-parameters of the EM wave absorber. The complex relative permittivity and permeability were calculated from the measured data and the variations according to a change of granularity were researched. As a result, it was confirmed that the EM wave absorber using flake sendust with the $140{\mu}m$ average granularity has outstanding absorption ability in high frequency range(C band) for the reduction of eddy current loss(increase of permeability) and the increase of space charge polarization(increase of permittivity).

Fabrication of the Micromachined Transformer using High Permeability NiFe Core (투자율이 높은 NiFe 코어를 이용한 마이크로 트랜스포머 제작)

  • Cho, Se-Jun;Cha, Doo-Yeol;Lee, Jai-Hyuk;Lee, Soo-Jin;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.194-198
    • /
    • 2010
  • Recently as the electronic devices are getting to be more and more smaller, transformers are needed to be micro fabricated using MEMS technology. In this paper transformers have been fabricated and measured by depositing insulation layer to reduce the loss of eddy current and in the middle core a high permeability permalloy was designed based on the turns ratio between primary coil and secondary coil which are 1:1 transformers. (the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7). The size of the transformers including ground shield are $1mm{\times}1.5mm$, $1mm{\times}1.95mm$, $1mm{\times}2.35mm$ respectively. The line width, pitch and the height of post are 50um. Based on the measured data from the micro fabricated transformers, the 3/3 turns in the primary coil and secondary coil showed the lowest insertion loss with 1.5 dB at 480 MHz and the 7/7 turns in the primary coil and secondary coil showed the highest insertion loss with 2.5 dB at 280 MHz. Also confirmed that the bandwidth goes up as the number of turns goes down. There was some difference between the actual measured data and the HFSS simulation result. It looks as if it is an error of the difference between oxidation of copper or the permeability of SU-8.

A Study on the Classification of Steam Generator Tube Defects Using an Improved Feature Extraction (개선된 특징 추출을 이용한 원전SG 세관 결함 패턴 분류에 관한 연구)

  • Jo, Nam-Hoon;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 2009
  • In this paper, we study the classification of steam generator tube defects using an improved feature extraction. We consider 4 axisymmetric defect patterns of tube: I-In type, I-Out type, V-In type, and V-Out type. Through numerical analysis program based on finite element modeling, 400 ECT signals are generated by varying width and depth of each defect type. From those generated ECT signals, we propose new feature vectors that include an angle between the two points where the Maximum impedance and half the Maximum impedance, and angles between Maximum impedance point and 10%, 20%, 30%, 40% of Maximum impedance points. Also, multi-layer perceptron with one hidden layer is used to classify the defect patterns. Through the computer simulation study, it is shown that the proposed method achieves an improved defect classification performance in terms of Maximum Error and mean square Error.

Preconditioning Phase for Open Ocean Formation in the Northern Part of Subpolar Front of the East Sea (외양대류에 의한 동해 심층수의 형성 가능성)

  • Lee Chung Il;Cho Kyu Dae;Kim San-Woo;Yun Jong-Hwui;Park Sung-Eun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2004.11a
    • /
    • pp.117-122
    • /
    • 2004
  • In order to investigate the initial stage of deep water formation between Vladivostok and the subpolar front in the East Sea, the factors, temperature, salinity, dissolved oxygen, measured by multi-ship surveys in 1969 have been used Deep water formation in the East Sea occurs in essentially two different forms: near continent and open ocean formation the position of eddy derived from potential vorticity matches well with that of deep water formation. The vertical and horizontal distributions of potential vorticity, geostrophic current, temperature, salinity and dissolved oxygen give clues for the preconditioning phase of open ocean formation like a doming of isotherm, associated with a cyclonic circulation

  • PDF

Construction and Performance of Magnetically Shielded Room for Biomagnetic Applications (생체자기계측을 위한 자기차폐실의 설치 및 특성)

  • 이용호;권혁찬;김진목;임청무;이상길;박용기;박종철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.264-271
    • /
    • 1996
  • A magnetically shielded room has been constructed for biomagnetic applications. The room has internal dimensions of $2\;m(length){\times}2\;m(width){\times}2.5\;m(height)$ and it consists of high permeability Mumetal and high conductivity alummum, utilizing ferromagnetic shielding and eddy current shielding. The de shielding factor around the center of the room is above 60 dB, and the ac shielding factors at 1 and 10 Hz are larger than 60 and 80 dB, respectively. The internal magnetic field noise at 1 Hz is $500\;fT/{\sqrt}Hz$ and at 10 Hz is $100\;fT/{\sqrt}Hz$, and the field gradient noise at 1 Hz is below $7\;fT/cm{\sqrt}Hz$. Successful measurements of cardiomagnetic fields usmg SQUID magnetometer and neuromagnetic fields using SQUID gradiometer have been done.

  • PDF

Effects of Annealing on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합 시트의 전자파 흡수 특성에 미치는 합금 어닐링 효과)

  • Kim, Ju-Beom;Noh, Tae-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2013
  • The soft magnetic Fe-Si-Cr flakes with the thickness of about 1 ${\mu}m$ were annealed at 500 and $700^{\circ}C$ for 1 h, and the composite sheets for electromagnetic wave noise absorber available for quasi-microwave band were fabricated by using these annealed flakes and polymer. Further the power loss characteristics of the composite sheets was investigated to clarify the annealing effect on electromagnetic wave absorption properties. The power loss decreased in the frequency range of several GHz when the annealed flakes were used as compared to the sheet using the as-milled FeSiCr alloy flakes. Moreover the sheets using annealed flakes exhibited lower value of real and imaginary part of complex permeability. These inferior electromagnetic wave absorption properties of the composite sheets using annealed alloy flakes were considered to be obtained by the enhanced eddy current effect upon annealing-induced recovery of microstructure and resulted low complex permeability.

Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube (증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발)

  • Park, Duck-Gun;Ryu, Kwon-Sang;Lee, Jeong-Kee;Son, De-Rac
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2008
  • A new ECT probe to separate the ECT signal distortion due to PVC (permeability variation clusters) and ordinary defects created in SG tubes has been developed. The hystersis loops of PVC which are extracted from retired SG (steam generator) tubes of Kori-1 NNP were measured. The tensile tests were performed to identify the mechanism of PVC creation. The conditions detecting the PVC created in 56 tubes were investigated using computer simulation, and the signal processing circuits were inserted in the probe for the digital signal transmission. The new Probe can measure and separate the PVC signal which is created in the SG tubes, and also measures the defects in Ni-sleeving part of SG tubes. furthermore the new ECT probe can measure the defects as fast as bobbin probe, and enhance the testing speed as well as reliability of the defect detection of SG tubes.

Study on Sea Level Changes in Korean Peninsula by Using Satellite Altimetry Data (위성 고도계 자료를 활용한 한반도 해수면 높이 변동 연구)

  • Hwang, Do-Hyun;Yoon, Hong-Joo;Seo, Won-Chan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.325-330
    • /
    • 2016
  • Sea level is upward trend since the end of 19th century, it is accelerating after 20th century. Because sea level height has regional differences, we concerned sea level change in Korean Peninsula. We used Topex/Poseidon, Jason-1 and Jason-2 satellite altimetry data which has $1/4^{\circ}$ resolution. From 1993 to 2013, for 21 years, monthly mean sea level anomaly was negative between January and April, positive between March and October. Bohai Bay in China, affected the continental climate, showed big sea level changes. Mean sea level data showed remarkably affecting the continental climate in Bohai Bay in China, the Kuroshio Current and eddy affects the sea level change.

The Experiment of Flow Induced Vibration in PWR RCCAs

  • Kim, Sang-Nyung;Cheol Shin
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.291-299
    • /
    • 2001
  • Recently, severe wear on the shutdown rod cladding of Ulchin Nuclear Power Plant #1, #2 were observed by the Eddy Current Test(E.C.T.). In particular, the wear at the sixth card location was up to 75%. The test results indicated that the Flow Induced Vibration(F.I.V.) might be the cause of the fretting wear resulting from the contact between Rod Cluster Control Assemblies(RCCAs) and their spacing cards(guide plates) arranged in the guide tube. From reviewing RCCAs fretting wear repots and analyzing the general characteristics of F.I.V. mechanism in the reactor, geometric layout and flow conditions around the control rod, it is concluded that the turbulence excitation is the most probable vibration mechanism of RCCA. To identify the governing mechanism of RCCA vibration, an experiment was performed for a representative rod position in which the most serious fretting wear experienced among the six rod positions. The experimental rig was designed and set up to satisfy the governing nondimensional numbers which are Reynolds number and mass damping parameter. The vibration amplitude measurement by the non-contact laser displacement sensor showed good agreements in the frequency and the maximum wearing(vibration) location with Ulchin E.C.T. results and Framatome report, respectively. The sudden increase in the vibration amplitude was sensed around the 6th guide plate with mass flow rate variation. Comparing the similitude rod behaviour with the idealized response of a cylinder in flow induced vibration, it was found that he dominant mechanism of vibration was transferred from turbulence excitation to periodic shedding at the mass flow ate 90ι/min. Also the critical velocity of the vibration in RCCAs was determined and the vibration can be prevented by reducing the bypass flow rate below the critical velocity.

  • PDF