• Title/Summary/Keyword: Eddy Current Signal

Search Result 130, Processing Time 0.028 seconds

Signal Characteristics of Eddy Current Test for Intergranular Attack of Steam Generator Tubes (증기발생기 전열관의 입계부식에 대한 와전류검사 신호특성)

  • Choi, Myung-Sik;Lee, Deok-Hyun;Cho, Se-Gon;Yim, Chang-Jae;Han, Jung-Ho;Hur, Do-Haeng
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.198-202
    • /
    • 2002
  • Beacuse intergranular attack (IGA), one of the locallized corrosion forms occurring on steam generator tubes, can not be fabricated by an electric discharge machining method, there are few data for the eddy current test (ECT) characteristics of IGA. In this paper, the characteristics of eddy current signals are evaluated using nonexpanded tubes with IGA defects formed in 0.1 M sodium tetrathionate solution at $40^{\circ}C$. The detectability and sizing accuracy of IGA were discussed in terms of the coil type and frequency of the ECT probes.

A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum (진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작)

  • Yu, K.K.;Kim, K.;Lee, Y.H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

Design of Remote Field Eddy Current Sensor for Water-Wall Tube Inspection using Simulation (시뮬레이션을 활용한 유동층보일러 수냉벽튜브 검사용 원격장 와전류 탐상 센서 설계)

  • Gil, Doo Song;Kwon, Chan Wool;Cho, Yong-Sang;Kim, Hak-Joon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • Thermal power generation accounts for the highest percentage of domestic power generation, among which coal-fired boiler generation accounts for the highest percentage. Coal boilers generate harmful substances and fine dust during coal combustion and have a serious effect on air pollution. So, fluidized-bed boilers have been introduced as eco-friendly coal boilers. It uses a fluid medium which affect the combustion temperature of coal. Because of it fluidized-bed boilers emit less pollutants than original one. Water-wall tubes play an important role in this fluidized bed boiler. Due to the fluid medium, the wall damage is more severe than the existing boiler. However, there is no quantitative maintenance technique in Korea yet. Remote field eddy current testing is a non-destructive evaluation technique that is often used for inspection of inner and outer wall of tube. it can inspect with non-contact and high speed. However, it is an inspection that proceeds from inside the pipe, and the water-wall tube is not able to enter the interior. In this study, we designed and simulated an external remote field eddy current sensor suitable for water-wall tube of a fluidized - bed boiler using simulations. By obtaining a signal similar to the existing remote field eddy current test, the criteria for the external remote field eddy current sensor design can be presented.

Drawing of Impedance Plane Diagrams of Absolute Coil ECT Signals by finite Element Analysis (유한요소해석에 의한 절대코일 와전류 신호의 임피던스 평면도 작성)

  • Shin, Young-Kil;Lee, Yun-Tai;Lee, Jeong-Ho;Song, Myung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.315-324
    • /
    • 2004
  • In eddy current testing(ECT), differential probes have been frequently used since they .an reduce the number of parameters that influence ECT signals. However, differential signal is actually the difference of the two coils' impedance so that signal prediction and interpretation are not easy, On the other hand, absolute coil signal is rather straightforward to predict and analyze. Therefore, combined use of the two types of signals would increase the test reliability. In this paper, absolute coil signals from Inconel plate and tubes are predicted by the finite element analysis and efforts of lift-off, fill-factor, conductivity, operating frequency, test specimen thickness, inner diameter defects, and outer diameter defects are investigated. As a result, various impedance plane diagrams are drawn and analyzed. Significant practical knowldege about absolute signals is accumulated and similar characteristics of the two types of signal could be understood. Finally, slope angle versus defect depth calibration corves are prepared for three different frequencies.

Development of Optical Fiber Displacement Sensor for Non-contact Vibration Measurement in the High Speed Rotation System (고속회전체의 진동 측정용 비접촉 광섬유 변위센서 개발)

  • Lee, Kee-Seok;Hong, Jun-Hee;Shin, Woo-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.50-56
    • /
    • 2005
  • This paper is described a development of an optical fiber displacement sensor. The optical fiber sensor using an intensity modulated measures the displacement between target and sensor. A prototype sensor is composed of a transmitting part, a receiving part and a signal processing circuit. The experiment was conducted not only the sensor performance but also factors that affect intensity. The main performance of this sensor is resolution of 0.37um and the non-linearity $0.7\%$ FS and the dynamic bandwidth of about 6.3kHz. As a result of rotation test, the prototype sensor showed an equivalent performance to a commercial eddy current sensor.

Nondestmctive Evaluation of Cracks in Metal Plates by using SQUID Gradiometer

  • 황윤석;김진태;이순걸;박용기
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.159-162
    • /
    • 2002
  • We have detected cracks inside multi-layer metal sheets with nondestructive evaluation system consisting of SQUID gradiometer. Double D-shape coil was carefully designed with computer simulation for spatial distribution of magnetic field. It was aligned and placed in between SQUID and metal sheets in order to reduce the field effect to SQUID and to maximize eddy current in the sheets. The metal plate in bottom of the metal stack contained artificial cracks which were scanned by an X-Y scanning system. The information of crack position and size could be estimated by analysis of SQUID signal. Details of the results will be discussed .

  • PDF

Burst Behavior of Wear Scar of Steam Generators Tubes (증기발생기 전열관 마모 파열 거동)

  • Kim, Hong-deok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • Nuclear steam generator tubes have experienced wear degradation at tube support structure. Morphology of wear scar was analyzed by using eddy current signal. A burst test facility for steam generator tubes was established and tubes with 3 types of defects were tested. The burst test results show that the depth of wear scar is the main factor influencing the burst pressure of tubes, meanwhile, both the longitudinal length and the angle also have effect on the burst pressure. Based on test results, the burst pressure equation for wear degradation was proposed.

  • PDF

Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging (자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계)

  • Oh, Chang-Hyun;Hilal, Sadek K.;Yi, Yun;Kim, Min-Gi
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF

Numerical Analysis Methods for Eddy Current Testing for Heat Exchanger Tube with Axi-symmetric Defects (열교환기 전열관의 결함에 대한 와전류 탐상 수치해석방법)

  • Kim, Chang-Wook;Seo, Jang-Won;Kim, Shin;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.831-833
    • /
    • 2000
  • In this paper, a numerical analysis algorithm of eddy current testing(ECT) for heat exchanger tube with axi-symmetric defects using finite element method(FEM) is presented. In the ECT FEM analysis, we used trianglular and rectangular elements for exact signal of ECT for variable shape of defects. This paper presents a systematic and efficient numerical analysis algorithm for ECT. We employ the LU decomposition and Cholesky method for solving the system matrix. This numerical analysis algorithm is effectively applied to heat exchanger tube with defects.

  • PDF

Development of Small Displacement Sensing System for Linear Motion Guide in Smart Factory (스마트팩토리의 리니어 모션 가이드를 위한 소형 변위 센싱 시스템 개발)

  • Lee, Suk-Yun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.403-405
    • /
    • 2022
  • 본 논문에서는 4차 산업에서 필요로 하는 스마트 기기의 소형 및 저전력 부품에 사용되는 센싱 플랫폼을 제안하였다. 특히 스마트팩토리의 공장 자동화와 정밀 측정의 핵심 부품인 리니어 모션 가이드(LM Guide)를 고정밀, 고정도로 제어할 수 있는 센싱 시스템을 개발하였다. 이를 위하여 기존의 변위 센서 기법의 한계를 극복할 수 있도록 와전류(Eddy Current) 기법을 이용함으로써 LC 공진기와 전도체를 LM 가이드에 장착할 수 있도록 구현하였다. 또한 미세 인덕턴스 값을 측정할 수 있도록 디지털 신호처리 기술과 컴퓨터/산술 기술을 FPGA를 이용한 HW 시스템을 제작하여 구현함으로써 실험을 진행했다. 본 논문에서 구현한 HW 센싱 시스템을 이용하여 LM 가이드를 동작시킴으로 실시간으로 변위 값을 디스플레이 부로 출력되어 측정이 가능하고, 변위 값의 분해능과 응답속도 면에서 우수함을 확인할 수 있다.

  • PDF