• Title/Summary/Keyword: Eddy Current Signal

Search Result 130, Processing Time 0.022 seconds

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Fuzzy Syntactic Pattern Recognition Approach for Extracting and Classifying Flaw Patterns from and Eddy-Current Signal Waveform

  • Kang, Soon-Ju
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.59-65
    • /
    • 1997
  • In this paper, a general fuzzy syntactic method for recognition of flaw patterns and for the measurement of flaw characteristic parameters for a non-destructive inspections signal, called eddy-current, is presented. Solutions are given to the subtasks of primitive pattern selection, signal to symbol transformation, pattern grammar formulation, and event-synchronous flaw pattern extraction based on the grammars. Fuzzy attribute grammars are used as the model for the pattern grammar because of their descriptive power in the face of uncertain constraints caused by nose or distortion in the signal waveform, due to their ability to handle syntactic as well as semantic information. This approach has been implemented and the performance of eh resultant system has been evaluated using a library of law patterns obtained from steam generator tubes in nuclear power plants by an eddy current-based non-destructive inspection method.

  • PDF

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing (와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析))

  • Chung, Tae-Eon;Chang, Kee-Oak;Park, Dae-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

Eddy Current Flaw Characterization Using Neural Networks (신경회로망을 이용한 와전류 결함 특성 평가)

  • Song, S.J.;Park, H.J.;Shin, Y.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.464-476
    • /
    • 1998
  • Determination of location, shape and size of a flaw from its eddy current testing signal is one of the fundamental issues in eddy current nondestructive evaluation of steam generator tubes. Here, we propose an approach to this problem; an inversion of eddy current flaw signal using neural networks trained by finite element model-based synthetic signatures. Total 216 eddy current signals from four different types of axisymmetric flaws in tubes are generated by finite element models of which the accuracy is experimentally validated. From each simulated signature, total 24 eddy current features are extracted and among them 13 features are finally selected for flaw characterization. Based on these features, probabilistic neural networks discriminate flaws into four different types according to the location and the shape, and successively back propagation neural networks determine the size parameters of the discriminated flaw.

  • PDF

Numerical Modeling of the Hall Sensor Signal Used in Pulsed Eddy Current Testing and Comparison of Its Characteristics with a Coil Sensor Signal (홀센서를 사용한 펄스와전류탐상 신호의 수치모델링 및 코일센서 신호와의 특성 비교)

  • Shin, Young Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.490-495
    • /
    • 2016
  • Pulsed eddy current (PEC) testing signals have typically been obtained from the electromotive force induced in a sensor coil. However, an increasing number of studies have elected to incorporate the Hall plate as a sensor. Thus, accurate numerical modeling of the Hall sensor signal is necessary. In this study, a PEC probe is designed and a numerical modeling program is written so that Hall sensor signals and coil sensor signals can be calculated simultaneously. First, a step current is used as the input current. The predicted Hall sensor signals show similar characteristics to those of the experimental signals reported by other researchers. The characteristics of the two types of signals are then analyzed and compared as the thickness of test object changes. The results show that the Hall sensor signal provides less information for evaluating the thickness of the test object than the coil sensor signal. The response signals from a pulsed input current are also calculated, and it is confirmed that an equivalent reversed signal pattern appeared after the pulse width at both signals.

Analysis of Spin Valve Tunneling Magnetoresistance Sensor for Eddy Current Nondestructive Testing

  • Kim, Dong-Young;Yoon, Seok-Soo;Lee, Sang-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.524-530
    • /
    • 2008
  • The spin valve tunneling magnetoresistance (SV-TMR) sensor performance is analyzed using Stoner-Wohlfarth model for the detection of eddy current signals in nondestructive testing applications. The SV-TMR response in terms of the applied AC magnetic field dominantly generates the second harmonic amplitude in hard axis direction. The second harmonic eddy current signal detection using SV-TMR sensor shows higher performance than that of the coil sensor at lower frequencies. The SV-TMR sensor with high sensitivity gives a good solution to improve the low frequency performance in comparison with the inductive coil sensors. Therefore, the low frequency eddy current techniques based on SV-TMR sensors are specially useful in the detection of hidden defects, and it can be applied to detect the deeply embedded flaws or discontinuities in the conductive materials.

Mold Oscillation Signal Detector of Eddy Current Mold Level Sensor (과류식(過流式) 연주(連鑄) Mold 탕면(湯面) 위치계(位置計)의 탕면진동신호(湯面振動信號) 검출방법(檢出方法))

  • Lee, Jin-Rak
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.37-38
    • /
    • 1988
  • In the continuous casting process, mold level sensor control system is very important for the quality of slab & bloom, in this paper, the principle of eddy current molr level sensor was studied and a method of mold oscillation signal detecting was purposed.

  • PDF

Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well.