• Title/Summary/Keyword: Eddy Current Loss

Search Result 218, Processing Time 0.023 seconds

The Effects of Heat-treatment on Magnetic Properties for Gas-atomized MPP Dust Cores (가스분무법으로 제조한 MPP 분말코어의 자기적 특성에 미치는 열처리 효과)

  • 노태환;김구현;김광윤;정인범;최광보
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.4
    • /
    • pp.173-178
    • /
    • 2001
  • The effects of heat-treatment with magnetic or non-magnetic field on magnetic properties of gas-atomized MPP dust cores subjected to various cooling processes after annealing were investigated. Upon magnetic-field annealing, ac permeability and core loss decreased with the increase of cooling rate, which were attributed to the generation of inhomogeneous internal stress and anomalous eddy current loss, respectively. It was not observed the formation of ordered phase and the related change in magnetic properties at the cooling stage for MPP dust cores. In MPP alloys, magnetic anisotropy was easily induced through the directional order, and permeability and core loss were changed under the conditions of low cooling rate and magnetic annealing.

  • PDF

Microstructural Change and Magnetic Properties of Nanocrystalline Fe-Si-B-Nb-Cu Based Alloys Containing Minor Elements

  • Nam, Seul-Ki;Moon, Sun-Gyu;Sohn, Keun Yong;Park, Won-Wook
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.327-332
    • /
    • 2014
  • The effect of minor element additions (Ca, Al) on microstructural change and magnetic properties of Fe-Nb-Cu-Si-B alloy has been investigated, in this paper. The Fe-Si-B-Nb-Cu(-Ca-Al) alloys were prepared by arc melting in argon gas atmosphere. The alloy ribbons were fabricated by melt-spinning, and heat-treated under a nitrogen atmosphere at $520-570^{\circ}C$ for 1 h. The soft magnetic properties of the ribbon core were analyzed using the AC B-H meter. A differential scanning calorimetry (DSC) was used to examine the crystallization behavior of the amorphous alloy ribbon. The microstructure was observed by X-ray diffraction (XRD), transmission electron microscope (TEM) and scanning electron microscope (SEM). The addition of Ca increased the electrical resistivity to reduce the eddy current loss. And the addition of Al decreased the intrinsic magnetocrystalline anisotropy $K_1$ resulting in the increased permeability. The reduction in the size of the ${\alpha}$-Fe precipitates was observed in the alloys containing of Ca and Al. Based on the results, it can be concluded that the additions of Ca and Al notably improved the soft magnetic properties such as permeability, coercivity and core loss in the Fe-Nb-Cu-Si-B base nanocrystalline alloys.

THE MAGNETIC PROPERTIES OF ULTRATHIN $Fe_{84}B_{9}Nb_{7}$ NANOCRYSTALLINE ALLOY

  • Lee, J.S.;Park, J.Y.;Kim, K.Y.;Noh, T.H.;Kang, I.K.;Yoo, Y.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.500-503
    • /
    • 1995
  • The magnetic properties of ultrathin $Fe_{84}B_{9}Nb_{7}$ nanocrystalline ribbon alloy with the thickness of $7-14\;\mu\textrm{m}$ were investigated. It was found that the effective permeability at the frequency over 100 kHz increased with decreasing ribbon thickness. Moreover the core loss decreased considerably with reduction of the ribbon thickness. The effective permeability at 1 MHz and the core loss at 1 MHz and 0.1 T for $Fe_{84}B_{9}Nb_{7}$ alloy with the thickness of $7\;\mu\textrm{m}$ were 3,700 and 2.7 W/cc, respectively. The reduction of thickness to less than $10\;\mu\textrm{m}$ was found to be very effective in obtaining high permeability and low core loss in the MHz frequency range. It was considered that the improvement of magnetic properties in the high frequency range was due to the reduction of the eddy current.

  • PDF

Prediction of Temperature Rise in Power Appratus (초고압 전력기기의 온도상승 예측)

  • Kim, S.W.;Park, J.H.;Hahn, S.C.;Lee, B.Y.;Park, K.Y.;Song, W.P.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.113-115
    • /
    • 2001
  • In order to design the power appratus such ac bus bar, the current carrying ampacity should be determined, Since it is limited by maxium operating temperature, it is very important to predict temperature-rise on it. The main causes to raise temperature are joule's loss in the current carrying conductor and induced circulating and eddy current in the tank. The heat transfer is divided into convection and radiation on boundary, determining convection heat transfer coefficient is not easy. This paper propose a new technique that can be used to estimate the temperature rise in the extra high voltage bus bar. The heat transfer coefficient is analytically calculated by applying Nusselt Number depending on temperature as well as model geometry. The analytic method which use heat transfer coefficient is coupled with finite element method. The temperature distribution in the bus bar by the proposed method shows good agreement with experimental data.

  • PDF

A Study on the magnetic properties of Mn-Zn Ferrite (Mn-Zn Ferrite의 자기적 특성에 관한 연구)

  • Kim Do-Hwan;Choi Young-Ji;Kwon Oh-Heung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.898-901
    • /
    • 2006
  • In this paper, effect of ceramic processing was investigated on the magnetic properties of low loss Mn-Zn ferrite. High frequency characteristics, high saturated magnetic flux density and high magnetic permeability and low magnetism loss are required for the development of Mn-Zn ferrite, which is parts in the communication. therefore, in order to improve Mn-Zn ferrite with a high frequency , it is important to have a minimal change of particles and to control the eddy current loss caused by high resistance of the stratum of particles and to reduce the hysteresis loss by uniform change of detailed structure. In this paper, we added $V_2O_5\;and\;CaCo_3$ to Mn-Zn Ferrite to achieve a high efficiency, low loss core material. The compositions are MnO : ZnO : $Fe_2O_3$ = 21 : 10 : 69 mol%. They were sintered at $1250^{\circ}C$ for Three hours. Initial permeability was measured at 0.1MHz. At 50mT, Power loss was measured by temperature changing at 100kHz.

  • PDF

A Study on Design of 50kW PMSG for Micro-grid Application (마이크로그리드용 50kW급 PMSG 설계에 관한 연구)

  • Jeong, Moon-Seon;Moon, Chae-Joo;Kim, Hyoung-Gil;Chang, Young-Hak;Park, Tae-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.527-536
    • /
    • 2014
  • In this paper, the 50kW aerogenerator which is applicable to the microgrid was designed and analyzed by using commercial simulation program Maxwell 2D. Particularly, the suggested PMSG to reduce the cogging torque introduced the offset and skew concept. The suggested optimal value of offset and skew was decided by 2mm and 60 degree of electric angle. The simulation results of the PMSG when load operation condition showed the average harmonic distortion 1.3%, voltage 322.41V, current 94.95A, and iron loss 9.73W, eddy current loss 73.68W, copper loss 3.52kW. The capacity of aerogenerator calculated 61.56kW, and the suggested design process can be applied to higher capacity generator.

Short Circuit Force and Eddy Current Loss Calculation using Image Method for Power Transformer (자기영상법을 이용한 전력용변압기 단락기계력 및 와전류 손실 계산)

  • Heo, Woo-Heng;Park, Jung-Ho;Cho, Ik-Choon;Lee, Dong-Yeup;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.77-79
    • /
    • 2006
  • 변압기에서 단락기계력에 대한 계산 분야는 수직력에 의한 Beam Bending, Tillting, 절연물 압축력과 수평력에 의한 Hoop, Compression 등이 있다. 본 논문은 전력용변압기 내부의 자계를 자기영상법을 이용하여 구하고 계산된 자계를 이용하여 단락 기계력을 구하는 방법을 제안하고자 한다. 또한 기존 FEM과 자기영상법과의 계산결과를 비교하였다.

  • PDF

Effect of Axial-Layered Permanent-Magnet on Operating Temperature in Outer Rotor Machine

  • Luu, Phuong Thi;Lee, Ji-Young;Kim, Ji-Won;Chun, Yon-Do;Oh, Hong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2329-2334
    • /
    • 2018
  • This paper discusses the thermal effect of the number of permanent-magnet (PM) layers in an outer rotor machine. Depending on the number of axial-layer of PM, the operating temperature is compared analytically and experimentally. The electromagnetic analysis is performed using 3-dimensional time varying finite element method to get the heat sources depending on axial-layered PM models. Then thermal analysis is conducted using the lumped-parameter-thermal-network method for each case. Two outer rotor machines, which have the different number of axial-layer of PM, are manufactured and tested to validate the analysis results.

Thermal Analysis of a Canned Induction Motor for Main Coolant Pump in System-Integrated Modular Advanced Reactor

  • Huh, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.32-36
    • /
    • 2003
  • The three-phase canned induction motor, which consists of a stator and rotor with a seal can, is used for the main coolant pump (MCP) of the System-integrated Modular Advanced Reactor (SMART). The thermal characteristics of the can must be estimated exactly, since the eddy current loss of the can is a dominant parameter in design. Besides the insulation of the motor winding is compared of Teflon, glass fiber, and air, so it is not an easy task to analyze. A FEM thermal analysis was per-formed by using the thermal properties of complex insulation which were obtained by comparing the results of finite element thermal analysis and those of the experiment. As a result, it is shown that the characteristics of prototype canned induction motor have a good agreement with the results of FEM.