공동주택의 주동 유형별 냉난방부하 분석 (Cooling and Heating Load Analysis According to Building Type of Apartment House)

  • 윤성민;이경희;안영철;김용태
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.45-50
    • /
    • 2014
  • This study focuses on the analysis of the cooling and heating load in accordance with apartment houses arrangement type using Ecotect Analysis. Korea have to reduce energy consumption part of building except in industry and transport because the rate of dependence on imports amounts to 94%, Apartment houses built in various forms in order to reduce energy are modelled in each window area ratio, shape, orientation, and climate through simulation. Through this study, we can analyze the cooling and heating load by form, window area ratio, orientation, and climate change and know the optimal elements by the form. In particular, although there have been done research on the window area ratio and the arrangement form, the research of the regional climate characteristics and the direction are hardly carried out. To supplement those problem, adding to seven direction and climatic element of southern region is characteristic(L Type, Y Type, - Type) of this study. The form of apartment houses built 10 years ago is modelled for simulation.

BIM을 이용한 건축물 초기 디자인 단계에서 초고층 업무용 건물의 최적 에너지 형태개발 (Development of Energy Optimized Geometry Using BIM for Super Tall Office Building in Early Design Stages)

  • 류한수;김인한;추승연
    • 한국CDE학회논문집
    • /
    • 제16권2호
    • /
    • pp.83-91
    • /
    • 2011
  • There are many researches to make low-energy building. Lots of them focus on facility systems and insulation performance of building materials. However, not only systematic solutions but also approaches in early design stages are important to reduce energy consumption. Using BIM(Building Information Modelling) is considered as an effective and efficient way to simulate building energy and decide alternatives than traditional energy simulation because BIM based energy simulation makes to reduce much time for energy modeling. This study focuses on development of optimized geometry for super tall office buildings in Seoul, Korea. Specifically, length to width ratio and building orientation are main topics of this study because these two topics are the most basic and preceding factors deciding mass design. In this study, Revit MEP 2011 and Ecotect Analysis 2011 are used to make case models and calculate energy load in early design stages. Energy properties of material abide by Korean Standards for Energy Conservation in Building, Korean Guideline for Energy Conservation in Public Office and ASHRAE Standard in USA. This study presents best length to width ratio of plan and optimized orientation by evaluating the case models. Furthermore, this study suggests what should be considered for each case to decrease energy load.

부하계산 프로그램에서 적용되는 인천지역의 시간당 일사량에 관한 연구 (The study of the solar radiation emitted per hour in Incheon applied in load calculation programs)

  • 유호천;이선동
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.108-117
    • /
    • 2010
  • Although many researches of simulation programs to predict climate under the current climate change have been performed but more detailed studies of weather date which might influence the load of buildings seem insufficient. In this study, in Incheon are analyzed IES (Integrated Environmental Solutions)6.0, Ecotect 2010, EnergyPlus v4.0's IWEC file and ISO-TRY, the Korean standard weather data provided by the Korean Solar Energy Society for direct normal radiation which is used in load calculation programs. The results show that the radiation of the programs is the same as that of direct normal radiation per month but has a mere difference, compared with the radiation per hour and IWEC has also 77.12% when compared with ISO-TRY, meaning that it could affect load values of buildings when applied to them. And in case of ISO-TRY, it could be judged that the application of test reference year applied by the data measured has higher reliability than IWEC file.

A study on the Healing Effects of UV-Day light for the healthy Leprosy Center through the ANOVA statistical analysis - Focused on 5S (Sort, Straighten, Shine, Standardize, Sustain)

  • Shaikh, Javaria Manzoor;Park, JaeSeung
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권4호
    • /
    • pp.7-18
    • /
    • 2013
  • Purpose: The aim of this paper is to reduce the stress and the disturbance occur in selective action of patient. This article will also help us to control spreading and reduce the order and bacteria produced by leprosy disease among the lepers. This will be achieved with the help of several variables and these variables help us on health benefits is 5S (Sort, Straighten, Shine, Standardize, Sustain) i.e. ratio of sectional morphology, lessor 90 degree angles, day light, universal design building and maximum ventilation. The replies from the questionnaire were collected based on varying levels of satisfaction and gloominess on the scale of 1-10. Methods: The multi-layer methodological framework for maximising the healing environment obtained from the observation of schemes and parameters of ANOVA: (Analysis Of Variance between five deciding factors) are. Firstly applied for the calculation of the patient's satisfaction for U.V light from sun on ECOTECT simulation, secondly the number of $90^{\circ}$ angle, along the corridors. Thirdly understanding the ways to represent people's perceptual structures and way finding with Space Syntax software. Fourthly the ratio of depth to height of the building typology and finally interviewing the subjects describing their special experiences based on scale value. The focus of this testing of human subjects was to receive data for the existence of image scheme in way-finding and to identify the mechanisms by which sun light impacts human (lepers) health. Results: AMPVA studies concluded that there is similarity between I and O plan as well as L and H plan whereas U plan was difference among the five selected architectural shapes. Implications: The purpose of this research is to show the effects of the I-type, L-type, C-type, U-type and O-type plan design, and to analyse the morphology for EBD (Evidence-Based Design) healing environment which is a universal design for Munghopir Karachi, in Pakistan.

도시농업 활성화를 위한 생태면적률 제도개선에 관한 연구 -단지내 일조조건 분석을 중심으로- (Study of Improving the Biotope Area Ratio System for Urban Agriculture Vitalization - Focus on Daylight Condition Analysis-)

  • 이건원;정윤남;민병학;김세용
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7393-7402
    • /
    • 2014
  • 본 연구는 최근에 높아지고 있는 도시농업 요구에 건축, 도시분야가 빠르게 대응하기 위해서 법제도적 장치로서 기존에 활용도가 높은 생태면적률의 개선에 주목한 연구이다. 기존의 생태면적률은 여러 작물생장조건 중 토심과 투수만을 다룬 지표로 조경식재 등의 관리에는 활용될 수 있으나 도시농업의 주요요소인 작물을 다루기에는 부족한 점이 있다. 본 연구는 이러한 가설을 증명하고 그 개선의 방향을 제시하는 것을 목적으로 했다. 본 연구를 통해서 실제로 생태면적률 지표만으로 작물생장까지를 다루기에는 한계가 있음을 밝힐 수 있었다. 또한 실제 단지계획상에서의 문제점을 도출할 수 있었다. 본 연구는 생태면적률에 빠져 있는 작물생장 조건 중 가장 중요한 일조를 중심으로 생태면적률 개선의 가능성 및 개선 방향을 타진했다는 점에서 도시농업 활성화를 위한 기초 연구를 수행했다는 점에서 의의를 지닌다.

옥상공간의 태양광 자원 해석을 통한 PV 시스템 및 녹화식재에 대한 적지조건분석 (The Analysis of Optimal Site Condition for Photovoltaic System and Green Roof Planting through Sunlight Component Simulation of Rooftop Area)

  • 김태한;박대근;권지영
    • 한국환경복원기술학회지
    • /
    • 제16권4호
    • /
    • pp.27-40
    • /
    • 2013
  • These day morden cities have serious climatic problems due to enviornmental load caused by excessive development of urbanization. As technological improvement to answer to various ecological disasters and climate changes are also called on the field of construction, inter-disciplinary studies linked to the estabilishment of sustainable energy generation systems and enviornmental control is needed in a consilient point of view. This study aims to analyse optimal site conditions for photovoltaic system and green roof planting through solar radiation simulation in a integrated perspective. In so doing, it seeks to proffer basic study for developing a sound use of roof area that is sustainable in environmental and resources aspects. A computer simulation showed that, in the case of total seasonal solar radiation, summer season resulted 312.5kWh in 35% of total annual solar radiation. This season indicated the lowest radiation rate of the year for direct sunlight in 45.8% of total seasonal solar radiation. Due to such solar radiation simulation, at the largest optimal planting area, Glechoma hederacea var. longituba secured $719.16m^2$ of gross roof area.

Building Integrated Vegetation Systems into the New Sainsbury's Building Based on BIM

  • Lee, Dong-Kyu
    • 한국BIM학회 논문집
    • /
    • 제4권2호
    • /
    • pp.25-32
    • /
    • 2014
  • Today, there is a growing need of environment-friendly buildings, so-called 'green', facilities, and energy saving buildings to decrease environmental pollutants released into cities by construction activities. Green-Building Information Modeling (Green-BIM) is a purpose-built solution which supports to forecast energy consumption of 3-D model of a building by augmenting its primary 3-D measurements (width, height and depth) with many more dimensions (e.g. time, costs, social impacts and environmental consequences) throughout a series of sequential phases in the lifecycle of a building. The current study was carried out in order to integrate vegetation systems (particularly green roof and green wall systems) and investigate thermal performance of the new Sainsbury's building which will be built on Melton road, Leicester, United Kingdom. Within this scope, a 3-D building model of the news Sainsbury's building was first developed in $Autodesk^{(R)}$ $Revit^{(R)}$ and this model was then simulated in $Autodesk^{(R)}$ $Ecotect^{(R)}$once weather data of the construction site was obtained from $Autodesk^{(R)}$ Green Building $Studio^{(R)}$. This study primarily analyzed data from (1) solar radiation, (2) heat gains and losses, and (3) heating and cooling loads simulation to evaluate thermal performance of the building integrated with vegetation system or conventionally available envelops. The results showed that building integrated vegetation system can potentially reduce internal solar gains on the building rooftops by creating a 'bioshade'. Heat gains and losses through roofs and walls were markedly diminished by offering greater insulation on the building. Annual energy loads for heating and cooling were significantly reduced by vegetation more significantly through the green roof system in comparison to green wall system.

종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data -)

  • 조주영;이기호;이효원
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가 (Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method)

  • 김동수;윤종호;신우철;이광호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

BIM 기반의 미시적 에너지 시뮬레이션에 관한 연구 -조도센서등의 조도 및 에너지 분석을 중심으로 (A Study of Microscopic Energy Simulation based on BIM - Illuminance & Energy Analysis of Illuminance Sensor Lighting)

  • 백지웅
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.384-390
    • /
    • 2019
  • 친환경 저에너지 중점의 건축설계의 중요성이 점점 커져가고 있다. 또 한편으로는 좀 더 미시적인 관점의 에너지 절약 설계 기법이 요구되고 있다. 이러한 분위기 속에서 에너지 시뮬레이션의 필요성이 점차 증가하고 있으며, 특히 BIM 기반의 에너지 시뮬레이션은 높은 효율성으로 인해 주목받고 있다. 하지만 BIM의 데이터는 아직까지는 미시적인 에너지와 관련된 파라메터가 적용되어 있지 않다. 따라서 본 연구는 조도 센서에 의한 조명 제어 시뮬레이션을 통해 센서 조명 파라메터의 생성 필요성에 대해서 연구하고자 한다. 연구는 BIM을 통해 생성된 데이터를 바탕으로 조도 센서를 설치하고 조도 시뮬레이션을 통해 센서등의 스케줄 데이터를 생성하였다. 그리고 이렇게 생성된 스케줄 데이터를 바탕으로 에너지 시뮬레이션을 실시하여 소비전력의 감소율을 확인하였다. 연구에 따르면 조명에 따른 열부하량과 소비전력량이 각각 20%이상 감소하는 것으로 나타났다. 따라서 센서 조명 파라메터는 미시적인 에너지 절약 설계를 위해서 BIM 데이터 내에 생성될 필요가 있다고 판단된다. 본 연구는 센서 조명 파라메터의 생성에 국한된 것이 아니라, 이와 같이 미시적인 변인들을 검토하고 BIM 데이터 내에 적용할 필요가 있음을 밝히기 위해 수행되었다.