• Title/Summary/Keyword: EcoDesign

Search Result 1,160, Processing Time 0.023 seconds

A Study on Aspheric Optics European LED Streetlights Type for the Prevention of Light Pollution (빛 공해 방지를 위한 유럽형 LED 가로등용 비구면 광학계에 관한 연구)

  • Lee, Shi-Woo;Lee, Chang-Soo;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.429-436
    • /
    • 2013
  • In this study, we researched a pendant-type aspherical optical system, which could be applied to street lighting and security lighting in Europe. The goal of this research was eco-friendly artificial lighting that could be used for the one-to-one replacement of ordinary lighting. LED lighting was miniaturized by using one COB LED Module and one aspherical optical system, which could control the luminosity of the LED. Through the aspherical optical system, the light distribution angle could be controlled in a range of $140^{\circ}$ for the X-axis and $40^{\circ}$ for the Y-axis. This means that this optical system is appropriate for catenary-type lighting, which is widely used in Europe on both narrow and broad roads. The performance was determined using a lighting simulation program. This lighting system simulation showed that road rates M4 and M5 could be satisfied, with the condition of a 13-m height and 50-m distance (U0 and TI). The simulation program estimated that light pollution, which disturbs sleep, could beeliminated in the European streetlight case. Determining methods for the light distribution control, performance, and optimal lighting setup conditions is very important to prevent light pollution. Moreover, the initial step of developing the lighting system design and post management will require an effort with much analysis.

Management Effectiveness Evaluation (MEE) Indicators Development in Protected Forest Areas (산림보호지역의 관리효과성 평가지표 개발 연구)

  • Ryu, Kwangsu;Choi, Jaeyong;Lee, Gwangyu
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.1
    • /
    • pp.105-119
    • /
    • 2011
  • In order to develop the indicators which evaluate the management effectiveness for the protected forest areas in Korea, candidate indicators were listed based on literature and experts interviews, then questionnaire survey on the experts were conducted. 5 elements of context, planning, input, process, output and outcome and 32 indicators were selected. Context element includes 6 indicators of 1) documentation and assessment of values; 2) documentation and assessment of threats, 3) influence of government policy, 4) related regulations, 5) community cooperation and 6) the structure of management organization. 6 indicators of Planning element were 1) the management objective, 2) protected area design, 3) protected area size and number, 4) representation, 5) standards and categories and 6) management planning. Input element of 3 indicators were 1) management staff, 2) funding, 3) establishment and application of information. Process element were consisted of 1) governance, 2) management guidelines, 3) human resource management, 4) law enforcement, 5) eco-management, 6) disaster management, 7) education program and 8) research and monitoring. The element of outputs and outcomes were 1) accomplishment of plan, 2) accomplishment of program, 3) private land management, 4) threats change, 5) biodiversity change, 6) ecosystem health and vitality, 7) impact on community, 8) international management level and 9) visitors' satisfaction and variation in civil compliant. It is recommended to have further research on evaluation methods development by applying those above developed indicators for the protected forest areas to ensure the practicality of the indicators.

The Development of Ecological Planting Model for the Make Up of Coastal Windbreak Forest on Suncheon Bay in Suncheon-si, Korea (순천만 해안방풍림 조성을 위한 생태학적 식재모델 개발)

  • Kim, Do-Gyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.1
    • /
    • pp.89-104
    • /
    • 2011
  • This study was carried out to the development of ecological planting model to make up of coastal windbreak forest on the Suncheon-bay in Sucheon-si, Korea. Make up of coastal windbreak forest in this site was needed for appropriate bioresource, biodiversity and ecological structure, and for conservation of the eco-tour resource and protection of human life and property by the unforeseen disaster from the coast. Based on the plant-social principle, the planting model of windbreak forest was developed to facilitate growth of trees, considering planting locations. The ecological planting model for the coastal windbreak was composed of warm temperate evergreen and windbreak forest which is spreading around the inland area in Korea. The horizontal forest style was composed of forest edge community and inner forest community, and the vertical forest style was composed of upper, middle, low and ground planting class. The target of the present model was quasi-natural forest, and the species of tree were selected based on the adaptability to surroundings depending on a goal to create a forest and forest style. To achieve both functions of wind break forest and visual effect in short period of time, small trees and seedlings were planted with high-density of 40,000/ha in an expectation of easy natural maintenance in the future. The significance of the present study is a suggestion for a guideline to create ecological coastal windbreak forest in the Suncheon-bay in which the harmony of human life and the ecological conservation is of great importance. Also, the ecological coastal windbreak forest model should be developed further through the long term monitoring after construction of forest.

Analysis of Seasonal Water Pollution According to the Reuse and Treatment of Wastewater from Anyang Stream (안양천 하수처리 재이용에 따른 계절별 수질오염 분석)

  • Lee, Yang-Kyu;Hong, Chang-Sun;Lim, Kwang-Su
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.2
    • /
    • pp.41-52
    • /
    • 2013
  • Anyang Stream Restoration Movement was started from 2001 for the construction of ecological city. The facilities for reuse of treated sewerage have been used since 2003 for improvement of water quality, maintenance of water quantity, river ecological restoration, and hydrophilic space. Thus, the Anyang city has been gradually transformed to eco-friendly city after the construction of Anyang stream and Hakui stream as natural rivers. In this study, biological and chemical methods as well as ecological indicators for Anyang mainstream and major tributaries were monitored for four years in between 2008 and 2012. The water quality and the diversity of species in most of the streams were found to be good except Anyang main stream. It appears that the influence of seasonal drying stream is almost disappeared except Sammak stream. Thus, the values for BOD (Biochemical Oxygen Demand) and BIP (Biological Index of Pollution) for Anyang main stream were found to be 5.27~3.42mg/l and 4.51~5.50, respectively. This is considered to be caused by the reused water quality of treated wastewater being exceeded the design criteria or by the non-point source of contaminants around the stream. However, entire section of tributaries shows I, II grade as a good water quality.

A Study for Natural Dyeing and Functional Property of Paper and Fabrics with Green Laver Extracts (파래 추출액을 이용한 지사용 원지와 직물의 천연 염색성 및 기능성에 관한 연구)

  • Kim, Ki Hoon;Kang, Sul Sang;Lim, Hyun A
    • Korean Journal of Human Ecology
    • /
    • v.23 no.5
    • /
    • pp.861-871
    • /
    • 2014
  • This study explored applicability of natural dyeing and functional property of base paper using paper yarn and fabrics with green laver extracts. As a result of measuring dyeability and functional property of cotton, silk, and a blended fabric of cotton/mulberry, $60^{\circ}C$ and 40 minutes was the optimal dyeing condition for the cotton fabric under an alkali condition; $50^{\circ}C$ and 60 minutes for the silk fabric; $60^{\circ}C$ and 50 minutes for the blended fabric of cotton/mulberry. As a result of measuring the color fastness after dyeing cotton, silk and the blended fabric of cotton/mulberry, fastness to washing, water, rubbing, dry cleaning and light was superior. In terms of functional property, the silk and the blended fabric of cotton/mulberry were superior concerning antimicrobial properties of the fabric dyed with green laver extracts while the cotton fabric showed 90% or over. Regarding deodorization, the blended fabric of cotton/mulberry was the most superior. All the fabrics were harmless to the human body as they had heavy metal content below the standard. Considering the research results comprehensively, the green laver extracts possibly has enough applicability and functional property as a natural dyes. Moreover, it has potential to be developed new eco-friendly fashion materials.

The Physical Property of Knitted Fabrics for High Sensible Garment according to the Spinning Method using Organic Cotton (오가닉 코튼 원사제조 방법에 따른 고감성 의류용 편성물의 물리적 특성)

  • Kim, Hyun-Ah;Kim, Hyun-Chel
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.606-612
    • /
    • 2013
  • This paper investigates the physical properties of organic cotton staple yarns manufactured by ring and siro spinning methods as well as analyzes the physical properties of fabric specimens knitted with staple yarns made by these two methods. The breaking stress and evenness of organic ring staple yarns showed the same level for the Japanese specimens as the control yarns; in addition, the same coefficient for the friction of the manufactured yarns and Japanese specimens was also shown. These results makes it possible to manufacture organic staple ring yarns from organic cotton fibers. The tenacity and breaking strain of siro staple yarns were higher than ring staple yarns. The evenness and friction coefficient of siro staple yarns were lower than the ring staple yarns; in addition, hairiness and the number of siro staple yarns was significantly lower than the ring staple yarns. The dimensional stabilities of knitted fabrics by 20 Ne and 30 Ne siro staple yarns were superior to ring staple yarns. The color fastnesses of washing, perspiration and abrasion of knitted fabrics by two spinning methods showed the same level as the 4.5 grade; however, the light fastness of knitted fabric by siro staple yarns was superior to ring staple yarns. It was shown that the siro spinning method (using eco-friendly organic cotton fibers) was applicable to a high sensible knitted garment that overcame drawbacks of organic fibers related to shrinkable properties after washing and low color fastness to light.

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

Numerical Simulation for the Subsurface Temperature Distribution Disturbed by Heat-Pump Operation (지열펌프 구동에 의한 지중 온도 분포 변화 모델링 연구)

  • Shin, Ji-Youn;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.40-43
    • /
    • 2006
  • Public demand for the heat pump system as a next generation energy equipment is increasing for its eco-friendly and cost-effective advantage. Many researches have been concentrated on how to calculate and develop its own efficiency, while the possible effect of the heat pump operation on the whole subsurface temperature distribution is relatively less considered, During the current study, subsurface temperature disturbance caused by seasonal surface temperature cycle in Busan area and general W-tube heat pump operation is simulated in 3-dimensional heterogeneous medium. It shows that subsurface deeper than 10m from the surface remains nearly unchanged throughout the 4 seasons and groundwater convect ion in highly permeable layer near the surface acts like a main path of heat plume from heat pump system, This implies the significance of detail descript ion in shallow sedimentary layer or highly permeable layer which plays an important role on the regional flow advection and heat transfer. Also, the effect of groundwater convection increases when the arrangement of the 2 injection pipes and 2 extract ion well is maintained parallel to groundwater flow. Therefore, more careful and detail investigation is required before installation and operation of heat pump system that it may not cause any possible change of microbial ecosystem in the shallow subsurface environment or 'contamination of temperature' for groundwater use as well as the loss of efficiency of the equipment itself. This can also help to design the optimized grouting system for heat pump.

  • PDF

Improvement of the Marine Environmental Assessment for Dredging and Ocean Disposal of Coastal Sediment in Korea (연안준설 및 준설토 해양투기 해양환경평가 개선방안)

  • Lee, Dae-In;Park, Dal-Soo;Eom, Ki-Hyuk;Kim, Gui-Young;Cho, Hyeon-Seo;Kim, Jong-Kyu;Seo, Young-Kyo;Baeck, Gun-Wook
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.3
    • /
    • pp.131-141
    • /
    • 2009
  • We studied improvement in marine environmental impact assessment and related management systems of coastal sediments that are dredged inshore but disposed offshore. After reviewing and diagnosing the existing assessment procedures and problems, we recommend to design the core assessment items and improve the reliability of assessment byenhancing the quality assurance/quality control (QA/QC) and verification processes. We proposed eco-friendly disposal plan for dredging sediment such as reuse system in land development was explored. A marine environmental database system was established to support the assessment processes. Guidelines for marine research and modelling were proposed for improving assessment of dredging and disposal of coastal sediment. Also, applying of screening and scoping for marine environmental assessment was reviewed.

Micro-scale Public Transport Accessibility by Stations - KTX Seoul Station Case Study - (정류장 단위의 미시적 대중교통 접근성 분석 - KTX 서울역 사례연구 -)

  • Choi, Seung U;Jun, Chul Min;Cho, Seong Kil
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • As the need of eco-friendly transportation systems for sustainable development increases, public transport accessibility has been considered as an important element of transportation system design. When analyzing the accessibility, shortest path algorithms can be utilized to reflect the actual movement and we can obtain high resolution accessibility for all other stations on the network with shortest distance and time. This study used the algorithm improved by reflecting the penalty of number of transfers and waiting time of overlapped routes to get the accessibility. KTX Seoul Station is a target place and this algorithm is applied to multi-layer subway bus network of Seoul to calculate the accessibility, therefore this study presented the accessibility of KTX Seoul station by stations.