• Title/Summary/Keyword: Echocardiographic

Search Result 261, Processing Time 0.024 seconds

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

Usefulness of echocardiographic findings in the early diagnosis of Kawasaki disease (가와사끼병의 조기 진단에서 심장초음파검사의 유용성)

  • Choi, Chang Hwan;Byun, Sung Hwan;Jeon, Je Duk;Choi, Jong-Woon
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.1
    • /
    • pp.47-51
    • /
    • 2007
  • Purpose : The early diagnosis of Kawasaki disease (KD) is difficult sometimes, especially in atypical or incomplete cases presenting 4 or less principal clinical features without coronary arterial lesions (coronary arterial ectasia or aneurysm). The authors investigated the incidence of echocardiographic abnormalities in patients with KD to discover whether abnormal echocardiographic findings might be helpful in the early diagnosis of KD. Methods : Echocardiography was done in the acute stage of 103 patients with KD (Kawasaki group) and 40 patients with other acute febrile illnesses (control group). Abnormal echocardiographic findings were classified into 4 categories and defined as follows; 1) significant pericardial effusion, 2) significant valvular dysfunctions, 3) left ventricular systolic dysfunction, 4) coronary arterial ectasia or aneurysm. Results : In the Kawasaki group, significant pericardial effusion was present in 24 patients (23.3 percent), significant valvular dysfunctions in 30 patients (29.1 percent), left ventricular systolic dysfunction in 10 patients (9.7 percent), and coronary arterial lesions in 27 patients (26.2 percent). In the control group, significant pericardial effusion was present in only one patient (2.5 percent). The number of patients with any one of echocardiographic abnormalities was 57 (55.3 percent) in Kawasaki group and one (2.5 percent) in control group. The sensitivity of echocardiography in the diagnosis of KD was 55.3 percent, the specificity 97.5 percent, the positive predictive value 98.3 percent, and the negative predictive value 45.9 percent. Conclusion : If abnormal echocardiographic findings, even if other than coronary arterial lesions, are confirmed in patients in whom KD is suspected, it seems desirable to inifiate specific treatment for KD.

Evaluations of vital signs and echocardiographic left ventricular function after the constant rate infusion of lidocaine and/or ketamine in Beagle dogs

  • Kim, Ye-Won;Choi, Miru;Kim, Tae-Jun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.4
    • /
    • pp.215-219
    • /
    • 2015
  • Cardiopulmonary depression of long-term constant rate infusion (CRI) administration of multiple analgesic drugs is important, especially in critically ill dogs. Therefore, this study was conducted to evaluate the effects of lidocaine, ketamine or combined lidocaine-ketamine combination CRI treatment on vital signs and left ventricular (LV) function in healthy dogs. Six adult Beagle dogs were administered either ketamine (initial loading dose of 0.5 mg/kg followed by $10{\mu}g/kg/min$ CRI), lidocaine (initial loading dose of 2 mg/kg followed by 0.025 mg/kg/min CRI), or combined lidocaine-ketamine intravenously. Arterial blood pressure (BP), heart rate (HR), respiratory rate (RR), body temperature (BT) and echocardiographic LV dimensions were measured before administration of medications, immediately after administration of drugs, and then every 10 min for 2 h. There were no significant changes in HR, RR, BT and BP after the administration of either lidocaine CRI, ketamine CRI, or combined lidocaine and ketamine CRI. There were also no significant changes in LV dimensions and stroke volume. The results revealed that treatment with either lidocaine, ketamine or combined lidocaine-ketamine may not cause cardiopulmonary suppression in healthy dogs.

Method of Deciding Elastic Modulus of Left and Right Ventricle Reconstructed by Echocardiography Using Finite Element Method and Stress Analysis

  • Han, Geun-Jo;Kim, Sang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.217-224
    • /
    • 1994
  • In order to study the shape and dimensions of heart, a procedure to reconstruct a three dimensional left ventricular geometry from two dimensional echocardiographic images was studied including the coordinate transformation, curve fitting and interpolation utilizing three dimensional position registration arm. Nonlinear material property of the left ventricular myocardium was obtained by finite element method performed on the reconstructed geometry and by optimization techniques which compared the computer predicted 3D deformation with the experimentally determined deformation. Elastic modulus ranged from 3.5g/$cm^2$ at early diastole to l53g/$cm^2$ at around end diastole showing slightly nonlinear relationship between the modulus and the pressure. Afterwards using the obtained nonlinear material propertry the stress distribution related with oxyzen consumption rate was analyzed. The maximum and minimum of ${\sigma}_1$ (max. principal stress) occurred at nodes on the second level intersection points of x-axis with endocardium and with epicardium, respectively. And the tendency of the interventricular septum to be flattened was observed from the compressive ${\sigma}_1$ on the anterior, posterior nodes of left ventricle and from the most significant change of dimension in $D_{RL}$ (septal-lateral dimension of right ventricle).

  • PDF

Echocardiographic Diagnosis of Subaortic Stenosis with Severe Deformation of Mitral Valve Apparatus in a Dog

  • Chung, Doo-ri;Yoon, Young-min;Hwang, Tae-sung;Choi, Moon-yeong;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.54-57
    • /
    • 2017
  • A 1-year-old castrated male Schnauzer dog was presented with heart murmur. Auscultation revealed systolic murmur located at the left heart base (grade 5/6). There were no remarkable findings on thoracic radiographs. Two-dimensional echocardiography revealed subaortic tunnel-like obstruction at the entrance to the left ventricular outflow tract. Anterior mitral valve leaflet appeared to be tethered to septum with minimal motion. Chordae tendineae was abnormally thickened. Color Doppler analysis revealed turbulent flow starting below the aortic valve. Mitral regurgitation was presented during systole. Spectral Doppler recordings revealed high velocity flow through the aorta and mitral regurgitation. Based on echocardiographic examination, the dog was diagnosed with subaortic stenosis concurrent with mitral dysplasia. The patient was medicated with ${\beta}-blocker$ and diuretics. It has been doing well without apparent clinical signs at 2 year after the diagnosis.

Electrocardiographic and Echocardiographic Characterisitics of Wolff-Parkinson-White Syndrome in Preschool Children (학동전 아동에서 Wolff-Parkinson-White 증후군의 심전도 소견에 따른 유형 및 심초음파 소견)

  • Chu, Jeoung Min;Sim, Hyun Sup;Cho, Soo Chul;Joo, Chan Uhng
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1097-1105
    • /
    • 2002
  • Purpose : This study was conducted to estabilish the prevalence, clinical features and relationship between ECG findings and echocardiographic findings of Wolff-Parkinsion-White(WPW) syndrome in asymptomatic preschool children. Methods : An electrocardiographic screening study was performed on 77,824 preschool children in Jeonbuk province from April, 1999 to August, 2001. Patients with WPW syndrome underwent echocardiographic study. Results : Twenty three patients with WPW syndrome were discovered by electrocardiographic screening of preschool children. The prevalence rate was 2.9 per 10,000 preschool children and there was no significant sexual difference. Two patients had a history of symptoms related to tachyarrythmia. According to the ECG classification of Rosenbaum et al., five patients were type A and 18 were type B. Utilizing the criteria of Gallagher et al, right anterior, 12 patients; right anteiror paraseptal, four patients; left anteiror, three patients. Nineteen of 23 patients underwent echocardiographic study. Four of five patients with type A WPW syndrome had abnormal early systolic anterior motion of left ventricular posterior wall. Twelve of 14 patients with type B had abnormal interventricular septal motion characterized by early sytolic posterior motion immediately after inscription of the delta wave. Conclusion : The prevalence rate of preschool children in Jeonbuk province was 2.9/10,000. By the classification according to the electrocardiographic findings, the accessory pathway location was dominant right side than left side. In the echocardiographic study, type A WPW syndrome showed abnormal left ventricular posterior wall motion and type B WPW showed abnormal interventricular septal motion.

The Feasibility of the DKUH-75 Left Ventricular Assist Device for Acute Cardiogenic Shock in Pigs (돼지의 급성 심인성 쇼크 모델에서 DKUH-75 좌심실보조키의 유용성에 관한 연구)

  • Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.168-179
    • /
    • 2007
  • Background: The recent trend of an increasing number of patients with acute cardiogenic shock or chronic congestive heart failure following myocardial infarction, as well as the considerable number who can not be weaned from cardiopulmonary bypass after open heart surgery, call for immediate efforts to develop affordable ventricular assist devices that are suitable for the Korean physique. Recently, a pneumatic pulsatile ventricular assist device (VAD), named DKUH-75, has been developed by the Department of Biomedical Engineering, in collaboration with the Department of Thoracic and Cardiovascular Surgery of Dankook University College of Medicine. The feasibility of the DKUH-75 VAD was evaluated on the bases of common hemodynamic variables and echocardiographic measurements in pigs, which are subjected to an acute cardiogenic shock state following myocardial infarction, using a novel coronary artery ligation method employing the ischemic preconditioning concept. Material and Method: Acute cardiogenic shock was induced in 10 Yorkshire Landrace Duroc strain pigs by ligating the left anterior descending coronary artery via an ischemic preconditioning process. The hemodynamic variables were monitored, with epicardial echocardiographic measurements performed before and one hour after the ligation. The DKUH-75 VAD was implanted into 5 pigs one hour after the onset of the shock. The hemodynamic variables and echocardiographic measurements were taken one hour after installation of the VAD. Result: The systolic, diastolic and mean systemic arterial pressures were significantly decreased in all the experimental animals one hour after the ligation. The systolic, diastolic and mean pulmonary arterial pressures were increased (Eds note: this completely contradicts the preceding statement? However, if you mean the non-experimental animals this should be stated?). The left ventricular end diastolic pressure (LVEDP) was increased, but the cardiac index decreased, An increase in the left ventricular end systolic dimension and decreases in the fractional shortening and ejection fraction were observed all animals one hour after the coronary artery ligation. In all 5 of the VAD implanted pigs, the systolic and mean systemic arterial pressures were increased, and the pulmonary arterial pressures decreased one hour after the implantation; the LVEDP decreased, but the cardiac index was significantly increased, In the echocardiographic measurements, the left ventricular end systolic dimension decreased after the implantation of the VAD, but the fractional shortening and ejection fraction significantly increased. Conclusion: Significant improvements in the hemodynamic variables and echocardiographic measurements were observed in the 5 VAD implanted animals one hour after installation, which had been subjected to an acute cardiogenic shock state by ligation of the coronary artery, indicating that the DKUH-75 VAD could help in the recovery of the myocardial function. This suggests that the DKUH-75 VAD is feasible in the short term in relation to an acute cardiogenic shock state due to myocardial infarction.

Importance of pulmonary valve morphology for pulmonary valve preservation in tetralogy of Fallot surgery: comparison of the echocardiographic parameters

  • Choi, Su Jin;Kwon, Jung Eun;Roh, Da Eun;Hyun, Myung Chul;Jung, Han Na;Lee, Young Ok;Cho, Joon Yong;Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.5
    • /
    • pp.189-194
    • /
    • 2020
  • Background: The decision to use transannular patching (TAP) during tetralogy of Fallot (TOF) repair depends on the pulmonary valve annulus size; the z score of the pulmonary annulus is the most commonly used predictor. However, definitive results are not obtained with z scores as different z score data sets are used for different parameters. Purpose: This study aimed to identify the echocardiographic and other key factors that warranted a change in the surgical method during TOF surgery. Methods: Sixty-two patients were enrolled and divided into a pulmonary valve (PV) preservation group and a TAP group. Their medical records were reviewed. Results: The z score for PV annulus (PVA), ratio of the PVA to aortic annulus size, and ratio of PVA to descending aorta (DAO) size were significantly different between the PV preservation and TAP groups (-1.72±1.52 vs. -3.07±1.94, P=0.004; 0.62±0.12 vs. 0.50±0.14, P=0.002; and 1.32±0.32 vs. 1.07±0.36, P=0.008, respectively). For TAP repair, the PVA z score had a sensitivity of 65.4% and specificity of 73.1%, ratio of PVA to aortic annulus size had a sensitivity of 73.1% and specificity of 65.4%, and ratio of PVA to DAO size had a sensitivity of 69.2% and specificity of 57.7%. The TAP group showed more monocuspid PVs (P=0.011), while the PV preservation group showed more tricuspid PVs (P=0.027). Commissurotomy was more frequently performed in the PV preservation group than in the TAP group (P=0.001). Of patients with commissurotomy, 58% showed a PV z score<-2. Conclusion: Although various echocardiographic parameters may serve as predictors for determining surgical methods for TOF patients, the PV morphology and tissue characteristics should also be considered.

Role and Clinical Importance of Progressive Changes in Echocardiographic Parameters in Predicting Outcomes in Patients With Hypertrophic Cardiomyopathy

  • Kyehwan Kim;Seung Do Lee;Hyo Jin Lee;Hangyul Kim;Hye Ree Kim;Yun Ho Cho;Jeong Yoon Jang;Min Gyu Kang;Jin-Sin Koh;Seok-Jae Hwang;Jin-Yong Hwang;Jeong Rang Park
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.85-95
    • /
    • 2023
  • BACKGROUND: The prognostic utility of follow-up transthoracic echocardiography (FU-TTE) in patients with hypertrophic cardiomyopathy (HCM) is unclear, specifically in terms of whether changes in echocardiographic parameters in routine FU-TTE parameters are associated with cardiovascular outcomes. METHODS: From 2010 to 2017, 162 patients with HCM were retrospectively enrolled in this study. Using echocardiography, HCM was diagnosed based on morphological criteria. Patients with other diseases that cause cardiac hypertrophy were excluded. TTE parameters at baseline and FU were analyzed. FU-TTE was designated as the last recorded value in patients who did not develop any cardiovascular event or the latest exam before event development. Clinical outcomes were acute heart failure, cardiac death, arrhythmia, ischemic stroke, and cardiogenic syncope. RESULTS: Median interval between the baseline TTE and FU-TTE was 3.3 years. Median clinical FU duration was 4.7 years. Septal trans-mitral velocity/mitral annular tissue Doppler velocity (E/e'), tricuspid regurgitation velocity, left ventricular ejection fraction (LVEF), and left atrial volume index (LAVI) at baseline were recorded. LVEF, LAVI, and E/e' values were associated with poor outcomes. However, no delta values predicted HCM-related cardiovascular outcomes. Logistic regression models incorporating changes in TTE parameters had no significant findings. Baseline LAVI was the best predictor of a poor prognosis. In survival analysis, an already enlarged or increased size LAVI was associated with poorer clinical outcomes. CONCLUSIONS: Changes in echocardiographic parameters extracted from TTE did not assist in predicting clinical outcomes. Cross-sectionally evaluated TTE parameters were superior to changes in TTE parameters between baseline and FU at predicting cardiovascular events.