• Title/Summary/Keyword: Echo signal

Search Result 475, Processing Time 0.02 seconds

Measuring Water Depth by Using a Combination of GPS/Echosounder (음향측심기와 위성항법을 이용한 하천의 수심 측량)

  • 정영동;강상구
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.375-381
    • /
    • 2002
  • Depth of water information is obtained mainly from echo-sounding instrument which observes the round-trip time of signal from water surface to the bottom. Photogrammetry, underwater survey and laser survey etc. are also used as another method of bathymetric surveying. These methods are used specially for making track chart in a shallow water area. On the other hand, aircraft or satellite imagery ara also used in the sea area where the effect of suspended material is low and water quality is good. Presently, general bathymetric surveying has been performed in our country, but the spatial density of surveyed point are relatively low. Therefore, in this study we built a grid water depth chart which measured combing echosounder with GPS-RTK method and the depth accuracy was analyzed by using the data of direct survey water depth. As a results, the bathymatric mapping which use echosounder is more economical method compared to the existing methods.

Conversational Quality Measurement System for Mobile VoIP Speech Communication (모바일 VoIP 음성통신을 위한 대화음질 측정 시스템)

  • Cho, Jae-Man;Kim, Hyoung-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2011
  • In this paper, we propose a conversational quality measurement (CQM) system for providing the objective QoS of high quality mobile VoIP voice telecommunication. For measuring the conversational quality, the VoIP telecommunication system is implemented in two smart phones connected with VoIP. The VoIP telecommunication system consists of echo cancellation, noise reduction, speech encoding/decoding, packet generation with RTP (Real-Time Protocol), jitter buffer control and POS (Play-out Schedule) with LC (loss Concealment). The CQM system is connected to a microphone and a speaker of each smart phone. The voice signal of each speaker is recorded and used to measure CE (Conversational Efficiency), CS (Conversational Symmetry), PESQ (Perceptual Evaluation of Speech Quality) and CE-CS-PESQ correlation. We prove the CQM system by measuring CE, CS and PESQ under various SNR, delay and loss due to IP network environment.

An Audio Watermarking Method Using the Attribute of the Tonal Masker (토널 마스커 특성을 이용한 오디오 워터마킹)

  • 이희숙;이우선
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.367-374
    • /
    • 2003
  • In this paper, we propose an audio watermarking method using the attribute of tonal masker. First, the attribute of tonal masker as an audio watermarking attribute is analyzed. According to existing researches, it is possible to be imperceptible modulation for the energies of the frequencies that compose a tonal masker. And when the relation between the tone energy and the left or right frequency energy after various signal processing is compared with the one before the processing, very few changes are showed. We propose an audio watermarking method using these attributes of tonal masker. A watermark bit is embedded by the modulation of the difference between the two neighboring frequency energies of a tone. In the detection, the modulated the tonal masker is searched using the key wed in the embedding without original audio and the embedded watermark bit is detected. After each attack of noise insertion, band-pass filtering, re-sampling, compression, echo transform and equalization, the detection error ratios of the proposed method were average 0.11%, 1.26% for Classics and Pops. And the SDG(Subjective Diff-Grades) scale evaluation of the sound quality of the watermarked audio result in the average SDG -0.31.

Effective Adaptive Dynamic Quadrature Demodulation in Medical Ultrasound Imaging

  • Yoon, Heechul;Jeon, Kang-won;Lee, Hyuntaek;Kim, Kyeongsoon;Yoon, Changhan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.468-475
    • /
    • 2018
  • In medical ultrasound imaging, frequency-dependent attenuation downshifts and reduces a center frequency and a frequency bandwidth of received echo signals, respectively. This causes considerable errors in quadrature demodulation (QDM), result in lowering signal-to-noise ratio (SNR) and contrast resolution (CR). To address this problem, adaptive dynamic QDM (ADQDM) that estimates center frequencies along depth was introduced. However, the ADQDM often fails when imaging regions contain hypoechoic regions. In this paper, we introduce a valid region-based ADQDM (VR-ADQDM) method to reject the misestimated center frequencies to further improve SNR and CR. The valid regions are regions where the center frequency decreases monotonically along depth. In addition, as a low-pass filter of QDM, Gaussian wavelet based dynamic filtering was adopted. From the phantom experiments, average SNR improvements of the ADQDM and the VR-ADQDM over the traditional QDM were 1.22 and 5.27 dB, respectively, and the corresponding maximum SNR improvements were 2.56 and 10.58 dB. The contrast resolution of the VR-ADQDM was also improved by 0.68 compared to that of the ADQDM. Similar results were obtained from in vivo experiments. These results indicate that the proposed method would offer promises for imaging technically-difficult patients due to its capability in improving SNR and CR.

New Performance Evaluation Method of Focused Ultrasonic Transducers By Using Virtual 3D Graphic (가상 3D 그래픽을 이용한 집속형 초음파 탐촉자 성능평가 방법)

  • Lee, Sun-Heum;Choi, Kwan-Sun;Kim, Dong-Sik
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.407-412
    • /
    • 2007
  • The performance of ultrasonic testing systems for industrial or medical purpose largely depends on the performance of ultrasonic transducers. Generally, the information about an ultrasonic transducer performance characteristics are expressed by the ultrasonic R/F signal back from a reflector and its frequency characteristics in the data sheet provided by manufacturers. In case of focused ultrasonic transducers, the two pieces of information can, however, hardly assure that the focused ultrasonic transducer would produce well-focused C-scan images. Therefore, we propose the measured size of focal spot and the reconstructed shape of effective focal zone in the focused sound field as novel measures for the performance evaluation of the focused ultrasonic transducers. The process of getting the both measures of the transducers is conducted by the implemented software including sound field scanning and virtual 3D reconstruction functions which requires the echo of a point reflector. The proposed method could, otherwise impossible in the existing method, effectively and simply distinguish superior ones among many transducers made in the same specification and be also used to detect the performance degradation due to the aging of the transducers. Eventually, the quality of performance of the ultrasonic testing systems for industrial or medical purpose is secured.

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

A Study on Mine Localization of Forward Looking Sonar Considering the Effect of Underwater Sound Refraction (수중 음파 굴절효과를 고려한 전방주시소나 기뢰 위치 추정기법 연구)

  • Sul, Hoseok;Oh, Raegeun;Yang, Wonjun;Yoon, Young Geul;Choi, Jee Woong;Han, Sangkyu;Kwon, Bumsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.231-238
    • /
    • 2022
  • Mine detection has been mainly studied with images of the forward-looking sonar. Forward-looking sonar assumes the propagation path of the sound wave as a straight path, creating the surrounding images. This might lead to errors in the detection by ignoring the refraction of the sound wave. In this study, we propose a mine localization method that can robustly identify the location of mines in an underwater environment by considering the refraction of sound waves. We propose a method of estimating the elevation angle of arrival of the target echo signal in a single receiver, and estimate the mine location by applying the estimated elevation angle of arrival to ray tracing. As a result of simulation, the method proposed in this paper was more effective in estimating the mine localization than the existing method that assumed the propagation path as a straight line.

The First Report on the Afternoon E-Region Plasma Density Irregularities in Middle Latitude

  • Yang, Tae-Yong;Kwak, Young-Sil;Lee, Jaewook;Park, Jaeheung;Choi, Seonghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.135-143
    • /
    • 2021
  • We report, for the first time, the afternoon (i.e., from noon to sunset time) observations of the northern mid-latitude E-region field-aligned irregularities (FAIs) made by the very high frequency (VHF) coherent backscatter radar operated continuously since 29 December 2009 at Daejeon (36.18°N, 127.14°E, 26.7°N dip latitude) in South Korea. We present the statistical characteristics of the mid-latitude afternoon E-region FAIs based on the continuous radar observations. Echo signal-to-noise ratio (SNR) of the afternoon E-region FAIs is found to be as high as 35 dB, mostly occurring around 100-135 km altitudes. Most spectral widths of the afternoon echoes are close to zero, indicating that the irregularities during the afternoon time are not related to turbulent plasma motions. The occurrence of afternoon E-regional FAI is observed with significant seasonal variation, with a maximum in summer and a minimum in winter. Furthermore, to investigate the afternoon E-region FAIs-Sporadic E (Es) relationship, the FAIs have also been compared with Es parameters based on observations made from an ionosonde located at Icheon (37.14°N, 127.54°E, 27.7°N dip latitude), which is 100 km north of Daejeon. The virtual height of Es (h'Es) is mainly in the height range of 105 km to 110 km, which is 5 km to 10 km greater than the bottom of the FAI. There is no relationship between the FAI SNR and the highest frequencies (ftEs) (or blanket frequencies (fbEs)). SNR of FAIs, however, is found to be related well with (ftEs-fbEs).

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Categorized VSSLMS Algorithm (Categorized 가변 스텝 사이즈 LMS 알고리즘)

  • Kim, Seon-Ho;Chon, Sang-Bae;Lim, Jun-Seok;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.815-821
    • /
    • 2009
  • Information processing in variable and noisy environments is usually accomplished by means of adaptive filters. Among various adaptive algorithms, Least Mean Square (LMS) has become the most popular for its robustness, good tracking capabilities and simplicity, both in terms of computational load and easiness of implementation. In practical application of the LMS algorithm, the most important key parameter is the Step Size. As is well known, if the Step Size is large, the convergence rate of the algorithm will be rapid, but the steady state mean square error (MSE) will increase. On the other hand, if the Step Size is small, the steady state MSE will be small, but the convergence rate will be slow. Many researches have been proposed to alleviate this drawback by using a variable Step Size. In this paper, a new variable Step Size LMS(VSSLMS) called Categorized VSSLMS (CVSSLMS) is proposed. CVSSLMS updates the Step Size by categorizing the current status of the gradient, hence significantly improves the convergence rate. The performance of the proposed algorithm was verified from the view point of convergence rate, Excessive Mean Square Error(EMSE), and complexity through experiments.