• Title/Summary/Keyword: Echo signal

Search Result 475, Processing Time 0.03 seconds

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

The Analysis of Brain Tumor's Grades Using Magnetic Resonance Spectroscopy (대뇌 종양에서 자기공명 분광법 적용 결과의 분석 연구)

  • Yun, Sang-Jun;Lim, Jong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.355-365
    • /
    • 2008
  • Purpose : This study isto determine the grade of brain tumor and compare the characteristics in each grade using in MRS (MR Spectroscopy). Method : STEAM (Stimulated Echo Acquisition Method) and protocol of PRESS (Point Resolved Spectroscopy) were used in the levels of tumor grade. We classified the pattern of tumor and analysis of the spectrum signals quantitatively from voxel in the brain tumor grade. In accordance with the result, we calculated the accuracy of biochemical. Result : In high-grade tumor, the NAA/Cr showed the signal reduction of 29.4% and 53.9%. However Cho/Cr increased 570% and 711%. However, in low-grade tumor, NAA/Cr downed to 42.6% and 58.1%. Cho/Cr increased to 188% and 195%. Conclusion : The study suggests that the comparative analysis of signals from MR spectroscopy could be useful to evaluate the grade of tumor and find out the characteristics of it. By extension, MR spectroscopy can be used for research with other organs in the human.

  • PDF

Analysis of the range estimation error of a target in the asynchronous bistatic sonar (비동기 양상태 소나의 표적 거리 추정 오차 분석)

  • Jeong, Euicheol;Kim, Tae-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.163-169
    • /
    • 2020
  • The asynchronous bistatic sonar needs to estimate direct blast arrival time at a receiver to localize targets, and therefore the direct blast arrival time estimation error could be added to target localization error in comparison with synchronous system. Direct blast especially appears as several peaks at the matched filter output by multipath, thus we compared the first peak detection technique and the maximum peak detection technique of those peaks for direct blast arrival time estimation through sea trial data. The test was performed in a shallow sea with bistatic sonar made up of spatially separated source and line array sensors. Line array sensors obtained the target signal which is generated from the echo repeater. As a result, the first peak detection technique is superior to maximum peak detection technique in direct blast arrival time estimation error. The result of this analysis will be used for further research of target tracking in the asynchronous bistatic sonar.

A Study of the Detection for Underclad Cracks of Nuclear Pressure Vessel (원자력 압력용기의 피복하부 결함검출에 대한 고찰(II))

  • Park, C.S.;Kang, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.31-39
    • /
    • 1993
  • It has not been performed to inspect the underclad cracking of nuclear pressure vessel in Korea since there is no code requirements for inspection. However, underclad cracks in nuclear pressure vessels have been reported since the early 1970s. The aim of this experiment is to find the suitable ultrasonic inspection techniques for underclad cracking. The various transducers, for example $70_{\backprime}$ refracted longitudinal wave, 50/70 multibeam, SLIC-40, SLIC-50, are used in this investigation. Experiments on prescreening blocks and a demonstration block under the same condition as in the nuclear power pressure vessels show that the $70_{\backprime}$ refracted longitudinal wave method is the best one for the length evaluation and also gives a good signal pattern for detection of the crack, while the 50/70 multibeam transducer is more effective for the detection of underclad cracking. On the other hand, the SLIC-50 transducer using M-SPOT(Satellite Pulse Observation Technique) and M-PET (Peak-Echo Technique) methods is the most effective one for the depth of underclad crack estimation.

  • PDF

Non-neoplastic Myelopathies Mimicking Intramedullary Spinal Cord Tumors : Retrospective Analysis of 8 Surgically Proven Cases (척수내 종양과 감별을 요하는 비종양성 척수증 : 수술로 확진된 8례의 후향적 분석)

  • Kim, Ki-Jeong;Chung, Chun-Kee;Sim, Ki-Bum;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.891-898
    • /
    • 2000
  • Objective : It is difficult to differentiate intramedullary spinal cord tumors preoperatively from non-neoplastic pathologies in patients presenting as non-compressive myelopathies in magnetic resonance imaging(MRI). In this report, the authors reviewed nonneoplastic intramedullary spinal cord lesions preoperatively diagnosed as tumors and discussed their clinical and radiological characteristics and usefulness of surgical intervention. Methods : From January, 1985 to January, 1999, authors experienced eight non-neoplastic pathologies mimicking intramedullary spinal cord tumors and analysed their medical records, radiological findings and histopathological specimens retrospectively. Results : There were five males and three females and the duration of symptoms were from two to 20 months(mean, 9.8 months). The location of lesions were four cervical, one cervicothoracic and three thoracic. All patients manifested sensory abnormality, seven motor weakness, and six bladder symptom. All cases had swollen spinal cords and increased signal intensities in spin-echo sequences. Six cases showed contrast enhancement : four cases were focal and two diffuse. Under the impression of intramedullary tumors, the patients were operated upon. Final diagnoses on the base of clinical and pathologic finding were : three subacute necrotizing myelopathies, two multiple scleroses, two myelopathy of unknown etiology. One case showed no gross abnormality in surgical field in spite of adequate exposure of the lesion, so biopsy was not performed. In that case, postoperative MRI revealed spontaneous resolution of the lesion. Conclusion : MRI is invaluable diagnostic tool in screening myelopathies. However, its high sensitivity and lack of specificity make difficulty in preoperative differential diagnosis of non-compressive myelopathies. Although no surgical morbidity occurred in our series, we sometimes failed to confirm definite diagnosis even with biopsy. In such a circumstance, long-term follow up is needed.

  • PDF

Development of Human Detection Algorithm for Automotive Radar (보행자 탐지용 차량용 레이더 신호처리 알고리즘 구현 및 검증)

  • Hyun, Eugin;Jin, Young-Seok;Kim, Bong-Seok;Lee, Jong-Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.92-102
    • /
    • 2017
  • For an automotive surveillance radar system, fast-chirp train based FMCW (Frequency Modulated Continuous Wave) radar is a very effective method, because clutter and moving targets are easily separated in a 2D range-velocity map. However, pedestrians with low echo signals may be masked by strong clutter in actual field. To address this problem, we proposed in the previous work a clutter cancellation and moving target indication algorithm using the coherent phase method. In the present paper, we initially composed the test set-up using a 24 GHz FMCW transceiver and a real-time data logging board in order to verify this algorithm. Next, we created two indoor test environments consisting of moving human and stationary targets. It was found that pedestrians and strong clutter could be effectively separated when the proposed method is used. We also designed and implemented these algorithms in FPGA (Field Programmable Gate Array) in order to analyze the hardware and time complexities. The results demonstrated that the complexity overhead was nearly zero compared to when the typical method was used.

The V(IV) Species, Locaton and Adsorbate Interaction in VH-SAPO-11 studied by ESR and ESEM

  • Back, Gernh-ho;Back, Seung-Chan;Park, Sung-Gun;Lee, Chul-wee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.1-20
    • /
    • 2005
  • Vanadium-incorporated aluminophophate molecular sieve VH-SAPO-11 has been studied by electron spin resonanace (ESR) and electron spin echo modulation (ESEM) spectroscopies to determine the vanadium locatin and interaction with various adsorbate molecules. As-synthsized VH-SAPO-11 contains only vanady1 species with distored octahral coordination. After calcinations in $O_2$ and exposure to moisture, only species A is observed with reduced intensities. Species A is suggested as a VO$(H_2O)_2^{2+$} complex coordinate to three framwork oxygen bonded to aluminum. When calcined, hydrate VH-SAPO-11 is dehydrated at elevated temperature, species A loses it water ligands and transforms to $VO^{2+}$ ions coordinated to three framework oxygens (species B). Species B reduces its intensities significantly after treatment with $O_2$at high temperature, thus suggesting oxidation of $v^{4+}$to $v^{5+}$. When dehydrated VH-SAPO-11 contacts with $D_2O$ at room temperature, the ESR signal of species A is observed. This species assumed as a $VO(O_f)_3(D_2O)_2$, by considering 3 framework oxygens. Adsorption of deuterated methanol on dehydrated VH-SAPO-11 results in another new vanadium species D, which is identified as a $VO(CD_{3}OH)$ complex. When deuterated ethanol is adsorbed on dehydrated VH-SAPO-11, another new vanadium species E identified as a $VO(C_{2}H_{5}OD)^{2+}$, is observed. When deuterated propanol is adsorbed on dehydrated VH-SAPO-11, a new vanadium species F identified as a $VO(C_{3}H_{7}OD)$, is observed. Possible coordination geometries of these various complexes are discussed.

  • PDF

A Design of Channel Models for the ISDN Subscriber Loops (ISDN 가입자 루프에 대한 전송로 모델의 설계)

  • 백제인;박원식;이유경
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.2
    • /
    • pp.293-305
    • /
    • 1994
  • In this paper the efficient channel models of the subscriber loops for the ISDN U-interface digital transmission are presented. Several configuration medels of the loop network are adopted from the CCITT recommendations, and various parameters specifying the physical dimensions are determined in accordance with the measurements of the loop characteristics of Korea. A typical loop interfacing circuit is applied at both ends of the loops and the overall transmissing circuit model is obtained. Based on this circuit model of transmission. 3 types of signal path models, related to transmission, echo, and near end crosstalk noise are defined and their transfer function are respectively derived as the channel models. As examples of the proposed channel models, numerical calculation has been performed for some loop configuration models and the channel responses are investigation in both domains of frequency and time. It is shown that various changes of the loop characteristics can well be explained in terms of the proposed models. And these models can efficiently be used for the simulation of the digital transmission over the subscriber loop.

  • PDF

Detection of Underwater Target Using Adaptive Filter (해수에서 물체 탐지를 위한 적응 필터의 이용에 관한 연구)

  • Oh, Jong-Taik;Kwon, Sung-Jai;Park, Song-Bai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.29-38
    • /
    • 1989
  • Detection of an underwater target by acoustic wave raises various difficulties due to unpredictable noise interference which originates from clutter, reverberation, and variations of medium characteristics with time and location. The SNR and the range resolution of conventional SONAR systems using a matched filter are generally poor, since the latter is optimum only in the additive white noise case. Furthermore, it cannot compensate for variations of the detection level which are responsible for the resultant detection errors. In this paper, the unpredictable interferences are compensated for by using an adaptive filter. It recursively estimates the channel impulse response based on the received echo signal. In the low noise environments, the estimated impulse response is close to the true one, providing a good range resolution, and a matched filter is used subsequently for the purpose of detection. It is shown through computer simulation that good performance can be achieved via the two steps of filtering. Also, the detection level remains unchanged without any additional provisions. Finally, we present the characteristics of the employed adaptive filter parameters.

  • PDF

Quantitative Analysis of T1 Weighted Images due to Change in TI by Using the Inversion Recovery in 3.0T Brain MRI Examination

  • Han, Jung-Seok;Dong, Kyung-Rae;Chung, Woon-Kwan;Cho, Jae-Hwan;Shin, Jae-Woo;Kim, Young-Jae
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.158-162
    • /
    • 2012
  • Although 3.0T magnetic resonance imaging (MRI) has the advantages of a higher signal to noise ratio (SNR) and contrast than 1.5T MRI, there are limitations on the contrast between white and grey matter because of the long T1 recovery time when T1 images are obtained using the Spin Echo Technique. To overcome this, T1 weighted images are obtained occasionally using the inversion recovery (IR) technique, which employs a relatively long TR. The aim of this study was to determine the optimal TI in a brain examination when a T1 weighted image is obtained using the IR technique. Eight participants (male: 7, female: 1, average age: $34{\pm}14.11$) with a normal diagnosis were targeted from February 18, 2012 to February 27, 2012, and the contrast between white and grey matter as well as the contrast to noise ratio (CNRs) in each participant were measured. The CNRs of white matter and grey matter were highest at TI = 600, 650, 750, 900, 1050 and 1100 ms when the TR was 1100, 1400, 1700, 2000, 2300 and 2600 ms, respectively. Therefore, as the TIs were $44.425{\pm}0.877%$ of the TRs in the TR range of 1400-2300 ms, the optimal T1 weighted images that describe the contrast between white and grey matter can be obtained if the TIs are compensated for with $44.425{\pm}0.877%$ of the TRs in the time of setting TIs.