• 제목/요약/키워드: Echo arrangement

검색결과 9건 처리시간 0.025초

대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선 (Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

초음파진동자의 복수배열에 의한 지향성가변에 관한 연구 (A Study on the Control of the Radiation Pattern of an Ultra-Sonic Beam by the Plural Arrangement of the Transducers)

  • 신형일
    • 한국항해학회지
    • /
    • 제3권2호
    • /
    • pp.21-30
    • /
    • 1979
  • Echo sounder and Doppler sonar are to theultra-sonic transducers for measuring the depth and the ship's speed respectively. To measure the depth and speed with a single transducer, it is required to control the ultra-sonic beam to optional direction. In the past, the direction of the transducer itself is varied, but such a method provoked much problems in the mechanical design of the equipment. This paper deals with the method to control beam direciton by the phase control of the plural arrangement of transducers, and the results are studied by a computer simulation. The remarkable results of the study is condensed as follows; 1. The greater the interval of arrangement between transducers, the sharper the radiation pattern is, but in this case, the level of undesired sidelobe is also increased. 2. The control of radiation pattern up to 60 degree can be achieved by an adequate arrangement of more than 10 transducers. 3. It is shown that a simultaneous measurement of both depth and speed can be achieved by alternating directivity of the pulse by the method proposed in this paper.

  • PDF

50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발 (Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder)

  • 이대재;이원섭
    • 한국수산과학회지
    • /
    • 제44권4호
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

가청화를 이용한 중학교 음악실의 음향성능 평가에 관한 연구 (A Study on the Evaluation of Acoustic Performance for Music Room in Middle School Using Auralization)

  • 설수환;강규선;김재수
    • 한국주거학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-57
    • /
    • 2008
  • The case study for this research is a middle school music room located in Iksan City, Korea. Although the room is used for teaching music, indiscreet sound-absorbing materials were applied within the space. Accordingly, a number of difficulties have been experienced when using the room. During a music lesson, the sound-volume is inadequate for music appreciation, while the music performance has an arid sound due to an insufficient echo. In order to control the obstructive factors resulting from a short Reverberation Time, the acoustic factor is optimized in this study by using an Acoustic Simulation, following an arrangement of Acoustic Design. A Psycho-acoustics Experiment was conducted using the Auralizational Technique, whereby the Virtual Acoustic Field can be experienced at the design stage.

결합형 속도 & 수심 측정기 고찰 (Development of a New Cost-Effective Alignment Method for Speed Log and Echo Sounder System)

  • 박형수
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2015년도 특별논문집
    • /
    • pp.28-33
    • /
    • 2015
  • Speed log measurement has always been of utmost importance to the mariners. To date the most accurate maritime speed measurement comes from Doppler measurement, where speed may be measured relative to either water(speed through water) or seabed(speed over ground). Recently, a clarification has been issued by the International Maritime Organization (IMO) regarding the speed measuring devices, which could ultimately impact the final arrangement of these devices for ships being constructed after July 1, 2014. This paper will discuss the clarification in depth and necessary action which shall be taken by the owners and operators of the ships impacted.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.57-65
    • /
    • 2001
  • 목적 : 초고속 Echo Planar Imaging (EPI) 의 데이터 측정시간을 반으로 단축시킨 half courier EPI와 임상에서 널리 사용하는 $T_2$ 강조 영상을 결합한 $T_2$-weighted half courier EPI(T2HEPl) 영상기법을 제안하였다. 제안한 방법으로 강한 $T_2$ 대조도를 갖는 $128{\times}128$의 고해상도 EPI 영상을 single scan으로 얻고자 한다. 대상 및 방법 : 초고속 EPI 기법의 데이터 측정시간을 줄이기 위하여 k-space의 절반만을 측정하고, 나머지 절반은 conjugate symmetry 성질을 이용하여 재구성한다. 따라서 64개의 에코로 $128{\times}128$의 고해상도 single shot 영상을 얻을 수 있다. 또한 k-space 데이터의 순서를 시간 축에서 조절하여 강한 $T_2$ 대조도를 갖는 영상을 얻을 수 있다 Eddy current의 영향으로 phase encoding 방향으로 잔류 경사자계가 있을 경우 측정된 데이터들은 k-space에서 이동이 되며 , 이것은 재구성 영상에 심각한 문제점을 초래하게 된다. 본 논문에서는 pre-scan에서 얻은 기준 데이터와 dc에 해당하는 에코간의 상관도를 측정하여 이동을 추정하며, 초기의 phase encoding gradient의 크기를 조정하여 이러한 이동을 제거한다. 결과 : 제안한 $T_2$-weighted half courier EPI 영상기법을 1.0 Tesla 전신 MRI 시스템에 적용하였다. 실험 조건은 single shot으로 TR은 무한대이고, TE는 72ms와 96ms로 설정하였다. 제안한 영상기법을 이용하여 single scan으로 강한 $T_2$ 대조도를 갖는 128x128의 고해상도 EPI 영상을 얻을 수 있었다. 결론 : 제안한 Half Fourier기법을 이용하여 기존의 $64{\times}64$ 영상보다 해상도를 높인 $128{\times}128$ EPI영상을 single scan으로 얻을수 있었으며, 에코의 적절한 배치를 통해 임상에서 널리 사용되는 $T_2$ 대조도를 얻을 수 있었다. 제안한 방법은 특별한 하드웨어의 추가 없이, 펄스 시퀀스와 tuning 및 재구성 알고리즘 등의 소프트웨어적인 방법만으로 구현이 가능하여 많은 임상 응용이 기대된다.

  • PDF

가청화(可聽化)를 이용(利用)한 중학교(中學校) 음악실(音樂室)의 음향성능평가(音響性能評價)에 관(關)한 연구(硏究) (A Study on the Evaluation of Acoustic Performance for Music Room in Middle School using Auralization)

  • 설수환;강규선;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.272-275
    • /
    • 2008
  • In case a middle school music room locating in Iksan City, this space had been finished its construction work with the indiscreet sound-absorbing materials despite the music lesson is taught thereat. Accordingly, when music lesson since it sounds aridly due to insufficiency of echo and sound-volume feeling in music appreciation or music performance sound, there is some difficulty in the music lesson. For the purpose to control the obstructive factors owing to such short Reverberation Time, it optimizes the acoustic factor using Acoustic Simulation after arrangement of Acoustic Design, it has conducted a Psycho-acoustics Experiment using the Auralizational Technique that can experience the Virtual Acoustic Field at its designing stage. As the result of investigation about the acoustic satisfaction on the relevant subject space and the satisfaction with regard to the pertinent each items, it was known that the valuation on acoustic performance was evidently improved at 'after-reformation' than 'before-reformation'. It is considered that such material could be utilized as the useful material that can improve the architectural acoustic factor when construction and renovation of any middle school music room in the future.

  • PDF