• 제목/요약/키워드: Eccentricity ratio

검색결과 216건 처리시간 0.025초

A Study on the Aerodynamic Drag of Transonic Vehicle in Evacuated Tube Using Computational Fluid Dynamics

  • Kang, Hyungmin;Jin, Yingmei;Kwon, Hyeokbin;Kim, Kyuhong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권4호
    • /
    • pp.614-622
    • /
    • 2017
  • The characteristics of aerodynamic drag for Transonic Vehicle in Evacuated Tube was investigated using computational fluid dynamics. At first, parametric study on the system was performed according to the Mach number of the vehicle's speed ($Mach_v$), evacuated pressure of the tube ($Pre_t$), and blockage ratio (BR) between the vehicle and tube via axisymmetric flow analysis; the $Mach_v$ ranged from 0.3 to 1.0. The $Pre_t$ was 100, 1,000 and 10,000 Pa and the BR was 0.1, 0.2, and 0.4. In the calculations, the aerodynamic drag of the vehicle was larger when the BR and the pressure became larger. Concerning the $Mach_v$, the drag coefficient ($C_d$) became the maximum when the $Mach_v$ was near the Kantrowitz limit and decreased, which showed the typical transonic flow pattern. Then, three dimensional flow analysis was performed by changing the $Mach_v$ from 0.3 to 1.0 and setting the BR and the $Pre_t$ as 0.34 and 100 Pa, respectively by referring the Hyperloop Alpha documentation. From the calculations, the $C_d$ from three dimensional flow simulations were somewhat larger than those of axisymmetric ones because of the eccentricity of the vehicle inside the tube. However, the pattern of $C_d$ according to the $Mach_v$ was compatible with that of axisymmetric ones.

Structural behaviour of tapered concrete-filled steel composite (TCFSC) columns subjected to eccentric loading

  • Bahrami, Alireza;Badaruzzaman, Wan Hamidon Wan;Osman, Siti Aminah
    • Computers and Concrete
    • /
    • 제9권6호
    • /
    • pp.403-426
    • /
    • 2012
  • This paper deals with the structural behaviour of tapered concrete-filled steel composite (TCFSC) columns under eccentric loading. Finite element software LUSAS is used to perform the nonlinear analyses to predict the structural behaviour of the columns. Results from the finite element modelling and existing experimental test are compared to verify the accuracy of the modelling. It is demonstrated that they correlate reasonably well with each other; therefore, the proposed finite element modelling is absolutely accurate to predict the structural behaviour of the columns. Nonlinear analyses are carried out to investigate the behaviour of the columns where the main parameters are: (1) tapered angle (from $0^{\circ}$ to $2.75^{\circ}$); (2) steel wall thickness (from 3 mm to 4 mm); (3) load eccentricity (15 mm and 30 mm); (4) L/H ratio (from 10.67 to 17.33); (5) concrete compressive strength (from 30 MPa to 60 MPa); (6) steel yield stress (from 250 MPa to 495 MPa). Results are depicted in the form of load versus mid-height deflection plots. Effects of various tapered angles, steel wall thicknesses, and L/H ratios on the ultimate load capacity, ductility and stiffness of the columns are studied. Effects of different load eccentricities, concrete compressive strengths and steel yield stresses on the ultimate load capacity of the columns are also examined. It is concluded from the study that the parameters considerably influence the structural behaviour of the columns.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

골프장 연못의 생태적 관리를 위한 환경특성 분석 (Analyses of the Environmental Characteristics of Ponds in Golf Courses for Ecological Management)

  • 안득수;김창환
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.51-77
    • /
    • 2006
  • Pond management is a critical part of overall golf course management, both during growth and maintenance modes of turf care. This study investigated 48 ponds in nine 18- or 27-hole golf courses to analyze the environmental characteristics of ponds. The research process had three phases: (1) inventory and analysis of grading plans and drainage plans, (2) field verification and interviews with greenskeepers, and (3) analyses of water quality and statistics. All data were collected from May to August in 2004. The results of this study can be summarized as follows: 1. It is desirable to site a golf course in a small watershed with high watershed eccentricity to control storm water runoff efficiently and to minimize soil erosion during construction. 2. The siting and size of a pond should be determined through a land-use analysis of the watershed for the purpose of ecological management. The bigger the forest-to-golf course ratio, the better the water quality will be. 3. The size and capacity of each individual ponds varied and there were many somewhat longish rather than round ponds. 4. There were many differences among golf courses in naturalness of the ponds, and the correlation between naturalness and area of aquatic plants was very high. 5. Analyses of pond water quality indicated that the degrees of Dissolved Oxygen, Chemical Oxygen Demanded and Suspended Solids were relatively low values but Total Phosphorus and Total Nitrogen were too high. Therefore a systematic approach is needed to solve e problem. Pesticide residues were not detected in all ponds. 6. Water depth and area of hydrophyte should be considered when designing an ecological pond. 7. All ponds used storm water as a main source of water supply and added underground water. Aquatic plants and physical methods such as water aeration and spray fountains were the main choices for maintaining a healthy aquatic environment.

고강도콘크리트충전 각형강관장주의 내력에 관한 실험적 연구 (An Experimental Study on Stength of Slender Square Tube Columns Filled with High Strength Concrete)

  • 서성연;정진안
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.471-479
    • /
    • 2002
  • 본 논문에서는 고강도콘크리트충전 각형강관장주에 대한 실험결과와 탄소성해석결과를 비교분석했다. 실험체는 모두 고강도콘크리트 충전 각형강관장주로 18개를 제작하였으며, 편심비에 따라 중심 및 편심가력하였다. 본 연구의 주요 파라메타는 단면폭에 대한 유효좌굴 길이의 비($L_K$/D)= 4, 8, 12, 24, 30와 가력편심비(e)=0, k, 3k이다. 본 논문에서 고강도콘크리트 충전 각형강관장주의 내력에 관한 해석 및 실험을 통하여 다음과 같은 결과를 얻었다. $L_K$/D=12 이하의 고강도콘크리트충전 각형강관단주는 콘크리트 감소계수 $c{\gamma}u=0.85$를 고려한 전소성내역에 도달했으나, $L_K$/D=18 이상의 장주실험체는 콘크리트 감소계수를 고려한 전소성내력에 도달하지 않았다. 실험에 의한 고강도콘크리트충전 각형강관장주의 탄소성거동은 제안된 해석치의 종국내력$N_{ASSUMED}$과 비교적 양호한 접근을 보여주었다. 콘크리트 압축강도의 감소계수 $c{\gamma}u=0.85$를 고려하지 않은 CFT설계기준과 고강도 콘크리트를 충전한 각형강관기둥의 실험결과치는 비교적 잘 일치함을 알 수 있었다.

Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns

  • Han, Lin-Hai;Zhao, Xiao-Ling;Tao, Zhong
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.51-74
    • /
    • 2001
  • A series of tests on concrete-filled SHS (Square Hollow Section) stub columns (twenty), columns (eight) and beam-columns (twenty one) were carried out. The main parameters varied in the tests are (1) Confinement factor (${\xi}$) from 1.08 to 5.64, (2) concrete compression strength from 10.7MPa to 36.6MPa, (3) tube width to thickness ratio from 20.5 to 36.5. (4) load eccentricity (e) from 15 mm to 80 mm and (5) column slenderness (${\lambda}$) from 45 to 75. A mechanics model is developed in this paper for concrete-filled SHS stub columns, columns and beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and filled concrete. The predicted load versus axial strain relationship is in good agreement with stub column test results. Simplified models are derived for section capacities and modulus in different stages of the composite sections. The predicted beam-column strength is compared with that of 331 beam-column tests with a wide range of parameters. A good agreement is obtained. The predicted load versus midspan deflection relationship for beam-columns is in good agreement with test results. A simplified model is developed for calculating the member capacity of concrete-filled SHS columns. Comparisons are made with predicted columns strengths using the existing codes such as LRFD (AISC 1994), AIJ (1997), and EC4 (1996). Simplified interaction curves are derived for concrete-filled beam-columns.

이산성 연속형 최적성 규준을 이용한 PPC 구조의 최적설계프로그램 개발 (Development of Optimum Design Program for PPC Structures using DCOC)

  • 한상훈;조홍동;이상근
    • 전산구조공학
    • /
    • 제10권4호
    • /
    • pp.315-325
    • /
    • 1997
  • 본 논문에서는 이산성 연속형 최적성규준방법을 이용하여 다지간 부분프리스트레스트 콘크리트보의 최적설계 알고리즘을 유도하였고, 최적설계프로그램을 개발하였다. 목적함수로서 건설 경비는 콘크리트 경비, 긴장재 경비, 철근 경비, 그리고 거푸집 경비를 포함하였으며 이를 최소화하였다. 설계제약조건으로는 시방서상의 최대처짐제약, 휨 및 전단강도제약, 연성제약 그리고 설계변수에 대한 상.하한계제약을 고려하였다. Kuhn-Tucker 필요조건을 이용하여 최적성규준을 설계변수의 항으로 명시적으로 유도하였으며, 이때 설계변수로는 보의 유효깊이, 긴장재의 편심거리 그리고 철근비를 취하였다. 긴장재의 형상은 포물선함수로 고려하였으며, 구조물 자중의 영향은 긴장력에 의한 이차효과와 마찬가지로 실제시스템의 평형방정식에서 고려하였다. 설계변수들의 개선을 위한 반복과정과 컴퓨터프로그램을 개발하였으며, 수치예를 들어 개발된 기법의 응용성 그리고 효율성을 보였다.

  • PDF

Experimental and finite element analyses of eccentric compression of basalt-fiber reinforced recycled aggregate concrete-filled circular steel tubular stub column

  • Zhang, Xianggang;Zhang, Songpeng;Yang, Junna;Chen, Xu;Zhou, Gaoqiang
    • Steel and Composite Structures
    • /
    • 제42권5호
    • /
    • pp.617-631
    • /
    • 2022
  • To study the eccentric compressive performance of the basalt-fiber reinforced recycled aggregate concrete (BFRRAC)-filled circular steel tubular stub column, 8 specimens with different replacement ratios of recycled coarse aggregate (RCA), basalt fiber (BF) dosage, strength grade of recycled aggregate concrete (RAC) and eccentricity were tested under eccentric static loading. The failure mode of the specimens was observed, and the relationship curves during the entire loading process were obtained. Further, the load-lateral displacement curve was simulated and verified. The influence of the different parameters on the peak bearing capacity of the specimens was analyzed, and the finite element analysis model was established under eccentric compression. Further, the design-calculation method of the eccentric bearing capacity for the specimens was suggested. It was observed that the strength failure is the ultimate point during the eccentric compression of the BFRRAC-filled circular steel tubular stub column. The shape of the load-lateral deflection curves of all specimens was similar. After the peak load was reached, the lateral deflection in the column was rapidly increased. The peak bearing capacity decreased on enhancing the replacement ratio or eccentric distance, while the core RAC strength exhibited the opposite behavior. The ultimate bearing capacity of the BFRRAC-filled circular steel tubular stub column under eccentric compression calculated based on the limit analysis theory was in good agreement with the experimental values. Further, the finite element model of the eccentric compression of the BFRRAC-filled circular steel tubular stub column could effectively analyze the eccentric mechanical properties.

주입재료에 따른 Anchor Bar의 인발저항 특성 (Pull-out Resistance Characteristics of the Anchor Bar According to the Grouting Material)

  • 여규권;송영석
    • 지질공학
    • /
    • 제18권2호
    • /
    • pp.227-232
    • /
    • 2008
  • 본 연구에서는 급경사면에 설치되는 여수로를 지탱하기 위한 Anchor bar의 인발저항 특성을 현장실험을 통하여 조사하였다. Anchor bar의 주입재료로 시멘트 모르타르와 시멘트 밀크를 사용하였으며, 조건별 주입재료의 일축압축강도를 측정하였다 측정결과 시멘트 모르타르와 시멘트 밀크는 물시멘트비가 증가함에 따라 일축압축강도가 감소하며, 재령일이 증가함에 따라 일축압축강도가 증가한다. 한편, 동일한 물시멘트비와 재령일을 가질 경우 시멘트 밀크의 일축압축강도가 시멘트 모르타르의 압축강도보다 더 큼을 알 수 있다. 현장에서 Anchor bar의 인발시험시 편심이 작용되지 않도록 하기 위하여 너트형태의 철근 고정커플링을 Anchor bar에 삽입하여 설치장비를 개선시켜 시험을 실시하였다. Anchor bar의 인발시험결과 시멘트 밀크의 경우 강도발현은 재령초기에 크게 발생되는 반면 시멘트 모르타르의 경우 재령일자가 지남에 따라 강도발현이 증가하였다. 따라서 Anchor bar의 신속한 시공을 위해서는 강도발현이 재령초기에 크게 발생되는 시멘트 밀크를 주입재료로 사용하는 것이 바람직하다.

축하중이 작용하는 철근 콘크리트 경계보-벽체 시스템의 압축성능 평가 (Structural Performance of the RC Boundary Beam-Wall System Subjected to Axial Loads)

  • 한진주;손홍준;김대진
    • 한국전산구조공학회논문집
    • /
    • 제35권1호
    • /
    • pp.57-64
    • /
    • 2022
  • 본 논문에서는 전이보 시스템이 지닌 층고 및 공사물량 증가의 단점을 보완할 수 있는 경계보-벽체 시스템의 압축성능을 평가하였다. 1/2 축소실험체에 대한 압축실험을 수행하고 그 결과를 3차원 비선형 유한요소해석 결과와 비교 및 분석하였다. 실험체 변수로 상하부벽체의 수평길이 상대비, 하부벽체의 두께, 하부벽체 전단보강근의 상세를 고려하였다. 실험의 최대하중은 하부벽체의 공칭축강도와 유사하게 나타났으며, 이로부터 상부벽체로부터의 수직 하중이 하부벽체로 원활하게 전달되며, 편심으로 인한 모멘트 중 상당량을 경계보가 가져감을 알 수 있다. 상하부벽체 수평길이의 상대비가 40%일 경우 50%일 때보다 단면의 기여도가 증가하였으며, 하부벽체에 면외방향 편심이 존재할 경우 단면의 기여도가 감소하였다. 하부벽체의 전단보강근 간격을 줄이고 크로스 타이를 배근할 경우 초기강성 및 최대하중이 증가하며 국부적인 응력집중이 감소하였다.