• Title/Summary/Keyword: Earthquake engineering

Search Result 4,953, Processing Time 0.032 seconds

Parametric study on earthquake induced pounding between adjacent buildings

  • Naserkhaki, Sadegh;Abdul Aziz, Farah N.A.;Pourmohammad, Hassan
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.503-526
    • /
    • 2012
  • Pounding between closely located adjacent buildings is a serious issue of dense cities in the earthquake prone areas. Seismic responses of adjacent buildings subjected to earthquake induced pounding are numerically studied in this paper. The adjacent buildings are modeled as the lumped mass shear buildings subjected to earthquake acceleration and the pounding forces are modeled as the Kelvin contact force model. The Kelvin model is activated when the separation gap is closed and the buildings pound together. Characteristics of the Kelvin model are extensively explored and a new procedure is proposed to determine its stiffness. The developed model is solved numerically and a SDOF pounding case as well as a MDOF pounding case of multistory adjacent buildings are elaborated and discussed. Effects of different separation gaps, building heights and earthquake excitations on the seismic responses of adjacent buildings are obtained. Results show that the seismic responses of adjacent buildings are affected negatively by the pounding. More stories pound together and pounding is more intense if the separation gap is smaller. When the height of buildings differs significantly, the taller building is almost unaffected while the shorter building is affected detrimentally. Finally, the buildings should be analyzed case by case considering the potential earthquake excitation in the area.

Estimation of the Maximum Potential Earthquake from the Fault Parameters (단층요소로부터 최대 잠재지진 평가에 관해서)

  • 장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.33-40
    • /
    • 2000
  • The assessment of earthquake hazards involved consideration of earthquake magnitude, frequency, last movement and probability of occurrence. The appraisal of earthquake potential is feasible because historical data show a good correlation between earthquake size and the fault rupture parameters of length, displacement, and area. Additionally, the characteristics of fault behavior should be considered to evaluate the earthquake potential magnitude. In this study, in order to evaluate the earth quake potential by the fault behavioral patterns, based on the experimental background which the geometric characteristics of the individual domains, such as strike, width, fault tip patterns, and orientation of secondary shears reflect sliding behavioral patterns in each section, the straight sections of A, D and E domains were examined to the creeping section of stably sliding. In contrast, the curved section of B domain was examined to the locked section of stick-slip movement. These results of studies can be applied to evaluate the earthquake potential magnitude from the fault structural parameters.

  • PDF

Behavior of Dams during the 1995 Hyogoken-Nambu Earthquake and Earthquake Resistance of Dams

  • Yamaguchi, Yoshikazu
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.3-14
    • /
    • 1999
  • The Hyogoken-Nambu Earthquake of January 17, 1995 inflicted severe damage in the Hanshin and Awaji areas such as has never been seen in Japan in recent years. The safety inspections of the dams conducted in the area by site offices and dam experts immediately after the earthquake showed that there was no damage affecting the safety of the dams although slight damage was observed in several dams. The investigation also revealed that the peak accelerations at dam sites were much smaller than those at soil sites. The Ministry of construction organized the Committee on Evaluattion of Earthquake Resistance of Dams after the earthquake. The Committee confirmed through dynamic analysis that the dams designed in accordance with the present design criteria in Japan are safe under the magnitude of shaking that occurred close the source fault of the Hyogoken-Nambu Earthquake.

  • PDF

Method of the Calibration of earthquake Ground Motions for Seismic Design (내진설계를 위한 지진 입력하중 조정 방법)

  • 공도환
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.20-27
    • /
    • 1998
  • In the current seismic design codes design earthquake is usually defined as the earthquake with the 90 percent probability of not being exceeded in the life time of a structure which is assumed as 50 years equivalent to the earthquake with 475 year recurrence period. However the life time of tall building structures may be much longer than 50 yers. The current seismic design code requires the modal analysis or dynamic time history analysis for the buildings with the height exceeding a certain height limit. The objective of this study is to collect the earthquake ground motion(EQGM) which can be used for dynamic time history analysis for tall buildings. For this purpose linear elastic design response spectrum (LEDRS) in the code is scaled to account for the recurrence period of the design earthquake. The earthquake ground motions which has been recorded are calibrated to fit the scaled LEDRS. The set of calibrated EQGM can be treated as design EQGM for the design of tall building with longer lifetime than ordinary building.

  • PDF

Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank (지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석)

  • Yun, Jang Hyeok;Kang, Tae Won;Yang, Hyunik;Jeon, Jong-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

Evaluation of Caisson Quay Wall Behavior during the 1995 Kobe Earthquake by Nonlinear Effective Stress Analysis (비선형 유효응력해석을 이용한 1995 Kobe 지진시 케이슨 안벽의 거동 평가)

  • Lee, Jin-sun;Noh, Gyeong-do
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.401-412
    • /
    • 2016
  • On Tuesday, January 17, 1995, an earthquake of magnitude 7.2 struck the Port of Kobe. In effect, the port was practically destroyed. After a hazard investigation, researchers reached a consensus to adopt a performance-based design in port and harbor structures in Japan. A residual displacement of geotechnical structures after an earthquake is one of the most important engineering demands in performance-based earthquake-resistant design. Thus, it is essential to provide reliable responses of geotechnical structures after an earthquake through various techniques. Today, a nonlinear explicit response history analysis(NERHA) of geotechnical structures is the most efficient way to achieve this goal. However, verification of the effective stress analysis, including post liquefaction behavior, is difficult to perform at a laboratory scale. This study aims to rigorously verify the NERHA by using well-defined field measurements, existing numerical tools, and constitutive models. The man-made, Port Island, in Kobe provides intensive hazard investigation data, strong motion records of 1995 Kobe earthquake, and sufficient engineering parameters of the soil. Two dimensional numerical analysis was conducted on the caisson quay wall section at Port Island subjected to the 1995 Kobe earthquake. The analysis result matches very well with the hazard investigation data. The NERHA procedure presented in this paper can be used in further studies to explain and examine the effects of other factors on the seismic behavior of gravity quay walls in liquefiable soil areas.

Estimation of seismic effective energy based parameter

  • Nemutlu, Omer Faruk;Sari, Ali;Balun, Bilal
    • Structural Engineering and Mechanics
    • /
    • v.82 no.6
    • /
    • pp.785-799
    • /
    • 2022
  • The effect of earthquakes in earthquake resistant structure design stages is influenced by the highest ground acceleration value, which is generally a strength-based approach in seismic codes. In this context, an energy-oriented approach can be suggested as an alternative to evaluate structure demands. Contrary to the strength-based approach, the strength and displacement demands of the structure cannot be evaluated separately, but can be evaluated together. In addition, in the energy-oriented approach, not only the maximum effects of earthquakes are taken into account, but also the duration of the earthquake. In this respect, it can be said that the use of energy-oriented earthquake parameters is a more rational approach besides being an alternative. In this study, strength and energy-oriented approaches of earthquake parameters of 11 different periods of single degree of freedom systems were evaluated over 28 different earthquake situations. The energy spectra intended to be an alternative to the traditional acceleration spectra were created using the acceleration parameter equivalent to the input energy. Two new energy parameters, which take into account the effective duration of the earthquake, are proposed, and the relationship between the strength-oriented spectral acceleration parameters and the energy parameters used in the literature is examined by correlation study. According to the results obtained, it has been seen that energy oriented earthquake parameters, which give close values in similar period situations, will be a good alternative to strength oriented earthquake parameters. It was observed that the energy parameters were affected by the effective duration of the earthquake, unlike the strength-based parameters. It has been revealed that the newly proposed energy parameters considering the effective duration give good correlations. Finally, it was concluded that the energy parameters can be used in the design, and the newly proposed effective energy parameters can shorten the analysis durations.

Why Worry about Earthquake in Regins of Moderate Seismicity : A Case-Study of Hong Kong

  • Kuang, Jun-Shang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.3
    • /
    • pp.111-119
    • /
    • 1998
  • This paper reports a part of research work on earthquake resistance consideration in regions of moderate seismicity, which is being carried out in the Department of Civil Engineering, Hong Kong University of Science & Technology. The possible seismic hazard in Hong Kong, which is located in a region of moderate seismicity, is described. A case study is presented to compare the wind and earthquake effects on Hong Kong buildings and to assess whether seismic analysis and desing is necessary for building structure. Potential problems of reinforced concrete buildings under earthquake effects in regions of moderate seismicity are discussed.

  • PDF

Obliquely incident earthquake for soil-structure interaction in layered half space

  • Zhao, Mi;Gao, Zhidong;Wang, Litao;Du, Xiuli;Huang, Jingqi;Li, Yang
    • Earthquakes and Structures
    • /
    • v.13 no.6
    • /
    • pp.573-588
    • /
    • 2017
  • The earthquake input is required when the soil-structure interaction (SSI) analysis is performed by the direct finite element method. In this paper, the earthquake is considered as the obliquely incident plane body wave arising from the truncated linearly elastic layered half space. An earthquake input method is developed for the time-domain three-dimensional SSI analysis. It consists of a new site response analysis method for free field and the viscous-spring artificial boundary condition for scattered field. The proposed earthquake input method can be implemented in the process of building finite element model of commercial software. It can result in the highly accurate solution by using a relatively small SSI model. The initial condition is considered for the nonlinear SSI analysis. The Daikai subway station is analyzed as an example. The effectiveness of the proposed earthquake input method is verified. The effect of the obliquely incident earthquake is studied.

Comparative Analysis of Earthquake Management in Pohang and Japan (포항 지진과 일본 지진관리 업무 비교·분석)

  • Kim, Su Ran;Kim, Hye Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.193-199
    • /
    • 2018
  • This study aims to create a disaster management system after an earthquake. Japan's earthquake disaster management system, including the Disaster Countermeasures Basic Act, addresses all of the disaster phases of prevention, mitigation, preparedness and emergency response as well as recovery and reconstruction with roles and responsibilities among the national and local governments clearly defined. Korea's earthquake disaster management system are including the Disaster Countermeasures Basic, but when the 9.12 earthquake occurred, problems such as insufficient early response, study on the earthquake lack were revealed. This study conducted a field survey and analyzed coping process after Po Hang earthquake. Therefore, this study have found that Disaster Management Headquarters are operated rapidly. They are coped with urgent safety inspection for damage facilities and soil liquefaction with advanced equipment. And The headquarters interviewed with victims. So they found out What the victims needed. However, when carrying out relief activities, Research of temporary housing and allocation of donations was not rapid. Further, this study have found that earthquake specialists were lack and disaster information transfer was not working. This study will be utilized as fundamental data in planning disaster management system after an earthquake.