• Title/Summary/Keyword: Earth resistivity

Search Result 468, Processing Time 0.023 seconds

Relationship between Hydraulic Conductivity and Electrical Resistivity of Standard Sand and Glass Bead (표준사와 유리구슬을 이용한 수리전도도와 전기비저항의 관계)

  • Kim, Soodong;Park, Samgyu;Hamm, Se-Yeong
    • Economic and Environmental Geology
    • /
    • v.46 no.3
    • /
    • pp.215-220
    • /
    • 2013
  • We estimated the hydraulic conductivity of the sediments using constant-head permeability tests and electrical resistivity measurements with Jumoonjin standard sand of a uniform size and glass beads of different grain sizes. In this study, we determined the variations of the porosity, the hydraulic conductivity, and the resistivity in case 1 (changing the packing of the Jumoonjin standard sand) and in case 2 (varying the size of the glass beads). The results of case 1 showed that the hydraulic conductivity decreased with an increase in the electrical resistivity. This occurred because the sand grain while packing became rhombohedral with the a decrease of both the pore size and porosity. The results of the case 2 showed that the hydraulic conductivity increased due to the increase in the pore size as caused by the increased glass bead size. In addition, the porosity decreased and the electrical resistivity increased. Therefore, the relationship between the hydraulic conductivity and the electrical resistivity is negatively proportional as regards the grain packing with a change from cubic to rhombohedral whereas this relationship is positively proportional to the increase in the grain size.

Analysis of a Weak Zone in Embankment Close to a Drainage using Resistivity Monitoring Data (전기비저항 모니터링을 이용한 저수지 제체 취수시설 취약성 해석)

  • Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2018
  • For the purpose of maintenance and prevention of earth fill dams against damage from natural hazards, automatic monitoring through various measuring instruments and resistivity survey has been carried out. Reservoirs and embankments have the structural vulnerability on the agricultural usages since most of them were built more than thirty years ago. The main aim to use monitoring method is to verify the safety and integrity of the dam. Resistivity survey can detect potential weaknesses, such as defective zones, anomalous seepages or internal erosion processes. Permanent resistivity monitoring systems were installed at a reservoir, which daily measurements have been taken every 6 hour. Using monitoring data for one year, anomalous seepage and structural defects were clarified for dam safety. Annual water level fluctuations are around 10 m. During their operation, reservoir dams are subject to a never-ending hydraulic load from the reservoir, which over the years may cause changes in the properties of the inner parts of the dam construction. Detailed analysis of the monitoring results was performed and showed that resistivities at most locations have been very stable over the full monitoring period excluding the effects of water fluctuation and seasons. To investigate the detectability of weak zone using the DC resistivity monitoring, numerical modeling with a simplified model for the drainage at a reservoir dam was also performed. The results showed that the seepage zone near drainage in a reservoir dam could be detected by resistivity response change.

Physical Property Factors Controlling the Electrical Resistivity of Subsurface (지반의 전기비저항을 좌우하는 물성요인)

  • Park Sam-Gyu
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.2
    • /
    • pp.130-135
    • /
    • 2004
  • This paper describes the physical properties of the factors controlling the electrical resistivity of the subsurface. Resistivities of various types of soil and rock samples saturated with sodium chloride solutions having nine different concentrations were measured, and the measured resistivities of these samples were compared with calculated resistivities obtained using the conventional empirical formulas. From the results obtained, we observed that the resistivity of the soil and rock samples increases with increasing in pore-fluids resistivity regardless of the media type. However, between 20 and 200 ohm-m, which is the normal range of resistivity of groundwater, the resistivity of the pore-fluids have little or no effect on the resistivities of the samples used. Below 10 ohm-m, the resistivities of the samples are mainly controlled by the pore-fluids, whereas, in the normal range of resistivity of groundwater, the sample resistivities are controlled by their intrinsic matrix resistivity more than by the pore-fluids resistivity. Also, the measured resistivity of rock and soil samples having more than $20\%$ clay contents showed a good agreement with the calculated resistivity using the parallel resistance model whereas, the calculated resistivities of glass beads correlate with that obtained using Archie's formula. When the pore-fluid resistivity is high, the computation of the resistivity values of the samples using the Archie's formula could not be carried out. Through this study, we were able to confirm that the tests are only applicable to the parallel resistance model considering the intrinsic matrix resistivity within the normal resistivity range of groundwater in the subsurface.

A Study on the Resistivity Structure in Central Myanmar Basin using DC Resistivity and Magnetotellurics (전기비저항 탐사와 자기지전류 탐사 자료를 이용한 미얀마 중앙분지 전기비저항 구조 연구)

  • Noh, Myounggun;Lee, Heuisoon;Ahn, Taegyu;Jang, Seonghyung;Hwang, InGul;Lee, Donghoon;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.2
    • /
    • pp.62-71
    • /
    • 2019
  • We conducted DC resistivity and MT survey to obtain the resistivity structure of the central Myanmar basin. We tried to analyze the underground structure through the resistivity variation of Myanmar by performing representative geophysical survey methods because researches on the electrical resistivity structure are insufficient in Myanmar. The electrical resistivity is expected to be low considering the marine sedimentary rocks composed of shale and sandstone in this area. The DC resistivity and MT survey were carried out using SmartRho of Geolux Co., Ltd. and MTU-5A of Phoenix geophysics Ltd., respectively, to visualize the electrical resistivity structure of study area. DC resistivity and MT survey showed an electrical resistivity less than dozens of ohm-m within the depth of 100 m. In particular, MT survey data were almost similar to TM and TE modes in the frequency range above 1 Hz. The two-dimensional inversion of MT data showed a subsurface structure with low resistivity below 150 ohm-m divided into east-west direction. We confirmed that the inversions of DC resisitivity and MT data along an overlapped survey line represented similar results. In the future, considering the high electrical conductivity, it would be effective to perform DC resistivity and MT survey simultaneously to study the electrical resistivity structure of the central Myanmar basin.

Geophysical Exploration on Unconformity-type Uranium Deposit in Athabaska Basin, Canada (캐나다 아타바스카 분지 부정합형 우라늄광상 물리탐사 사례)

  • You, Young-June;Kim, Jae-Chul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.05a
    • /
    • pp.73-87
    • /
    • 2009
  • Geophysical survey for unconformity-type uranium deposit applied to this study area in Athabaska Basin, Canada were carried out airborne TEM and magnetic, resistivity-induced polarization (DC-IP), puser seismic reflection and well-logging method. The results of airborne survey interpreted the lithological boundary, geological structures, and conductors. Also, these results decided to main targets for ground DC-IP survey. The Low resistivity and the high chargeability slices of 3D modeling interpreted from DC-IP survey response for conductors related to hydrothermal alteration zones and fault-controlled graphitic zones occurring at the unconformity-type uranium deposit, and they confirmed by diamond drilling. Seismic results interpreted to lake bottom surface, alluvium layer and intra-sandstone faults. We suggest the resonable field data acquisition of DC-IP method on the land or the lake in Athabaska Basin.

  • PDF

Case histories of geotechnical survey for civil construction in rural sites (농촌지역 토목공사를 위한 지반조사 사례)

  • Kwon, Hyoung-Seok;Oh, Se-Young;Kim, Ki-Seog
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.87-111
    • /
    • 2000
  • In this study, we describe the principle and result of geophysical techniques which are widely used in geotechnical survey. Also we discuss two case histories. One is discrimination of limestone cavity areas by resistivity, seismic tomography, televiewer, well logging, and the other is discrimination of coal by resistivity, electromagnetic method, resistivity tomography.

  • PDF

Electrical Responses on Mineralized Zone in Geumpung Mine (금풍광산 광화대에 대한 전기탐사 반응)

  • Jung, Yeon-Ho;Kim, Jung-Ho;Byun, Joong-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.231-236
    • /
    • 2007
  • Electrical resistivity, self-potential and time-domain induced polarization methods were conducted for study of electrical responses on vein-type sulfides ore, which is intruding limestone and dolomite of Ordovician, of Geumpung mine located in Dojeon-ri, Susan-myeon, Jecheon-si, Chungbuk. Sulfides bearing chalcopyrite, pyrrhotite and galena etc. are deposited in disseminated or vein-type. Good result that resistivity and self-potential surveys detect high grade-estimated mineralized zone located in upper part of existing low grade ore zone is acquisited and is to some extent consistent with induced polarization. Furthmore, a new mineralization zone directing EW is detected.

  • PDF

A Case of Reducing Grounding Resistance of 154KV Substation (154KV 변전소의 접지저항 저감대책 검토사례)

  • Kee, H.T.;Choi, J.K.;Jung, G.J.;On, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2064-2067
    • /
    • 2000
  • In our country, most region is composed of mountains and people have recently been displeased with the construction of the substations in their vicinity so the substations newly built are mainly constructed with GIS system in the small area that has high soil resistivity near mountain. Therefore, nowadays the design of substation grounding system has been difficult, and the additional considerations are needed. UC substation was also difficult to design the grounding system because of so small substation area and high soil resistivity. This paper shows the examples of reducing the grounding system resistance reasonably by using several ways. Designing the ground grid electrode in the access road, deep electric earth probe, changing the substation soil with the law level resistivity soil. This report deals with the computer simulation of the grounding system resistance about the ways illustrated above.

  • PDF

CONDUCTIVITIES OF SEA-BOTTOM SEDIMENTS

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2003
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature- monitoring systems. Overall limits of uncertainty at respective depths below the seafloor are up to ±10% of the measured values. Best estimates of conductivity are considered to be ±3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

Estimation of Soil Resistivity Parameter for Optimal Grounding Design (최적 접지설계를 위한 대지파라메터의 추정)

  • Lee, Hyung-Soo;Lee, Kwan-Hyung;Lee, Bong-Yong;Shim, Keon-Bo
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.61-63
    • /
    • 1994
  • Accurate estimation of soil resistivity parameters are very important in the design of grounding systems. This paper presents a useful methodology for the optimal estimation of soil parameters based on the weighted least square concepts using a set of earth resistivity measurements by Wenner method. And, this paper developes a computer simulation programming for the estimation of soil parameters. Results are presented and compared with the results of other methods.

  • PDF