• Title/Summary/Keyword: Earth resistivity

Search Result 468, Processing Time 0.023 seconds

Electrical Responses on the Auriferous Mineralized Bone in Sambo Mine (삼보광산 금 광화대에 대한 전기탐사 반응)

  • You Youngjune;Yoo In-Kol;Kim Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.217-224
    • /
    • 2004
  • Self-potential and electrical resistivity methods were conducted for locating the auriferous mineralized zone, called Jija Vein, of Sambo mine, Limsu-ri, Haeje-myeon, Muahn-gun, Jeollanam-do. The host rocks of the mineralization include gneiss, rhyolite and felsic dyke. Ore vein is mainly fissured-filling type and sulfide minerals, such as pyrite, are disseminated in country rock. By the electrical responses from SP and surface resistivity methods., the mineralized zone is supposed to extend about 360 m directed N5W with the width of 20 m to 30 m. From resistivity tomograms using inclined borehole to surface, the ore body shape is interpreted as the width of 20 m in depth 40 m to 50 m.

Behavior of Shear Zone by Improved Direct Shear Test (개선된 직접전단시험을 이용한 전단영역의 거동)

  • Byeon, Yong-Hoon;Truong, Q. Hung;Tran, M. Khoa;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.607-614
    • /
    • 2010
  • Shear behavior of granular soils largely affects the safety and stability of underground and earth structures. This study presents the characteristics of shear zone in a direct shear test using shear wave and electrical resistivity measurements. An innovative direct shear box made of transparent acrylic material has been developed to prevent direct electric current. Bender elements and electrical resistivity probe are embedded in the wall of direct shear box to estimate the shear wave velocities and the electrical resistivity at the shear and non-shear zones. Experimental results show that the void ratio and shear wave velocity at shear zone increase during shearing while the values remain constant at non-shear zone. The results demonstrate correlation among the contact force, small strain shear modulus, and void ratio at shear zone. This study suggests that the application of the modified direct shear box including shear wave and electrical resistivity measurements may become an effective tool for analyzing soil behavior at shear zone.

  • PDF

Electrical resistivity monitoring of a scale model experiment for geological $CO_2$ sequestration (전기비저항에 의한 지중저장 이산화탄소 거동관측 모의실험)

  • Park, Mi-Kyung;Jang, Han-Nu-Ree;Kim, Hee-Joon;Wang, Soog-Yun;Lee, Min-Hee
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.173-178
    • /
    • 2007
  • Time-lapse electrical resistivity measurements have been made in a scale model experiment for geological $CO_2$ sequestration in aquifer. Three types of $CO_2$ injection are tested in a water tank filled with glass beads. These are $CO_2$ dissolved into filtered tap water, $CO_2$ gas, and mineral oil. The mineral oil is a substitute for liquid phase of supercritical $CO_2$. For reconstructing three-dimensional resistivity images, we measure potential differences at 32 potential dipoles on the top surface of the tank due to two current dipoles on the front and back sides. The resultant resistivity images clearly show the movement of injected $CO_2$ in aquifer.

  • PDF

Analysis of Soil Properties in a Rice Field Using Small Loop EM Method (소형루프 전자탐사에 의한 논 토양분석)

  • Yong Hwan-Ho;Song Sung-Ho;Kim Jin-Ho;Cho In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.207-214
    • /
    • 2003
  • To analyze soil properties with depth in rice field, we compared resistivity distributions obtained from soil analysis with one dimensional inversion of small loop electromagnetic (EM) data. Although it didn't show consistency exactly between the two resistivity distributions, low resistivity zones in soil analysis, appeared to agree with low resistivity zones in EM result. Therefore, small loop EM method can be applied to obtain rapidly the soil properties such as salt accumulation in a rice field. If research on soil property and EM responses of unsaturated zone would be conducted consistently, small loop EM method can be used effectively to detect salt accumulated zone in agricultural area.

Analysis on Coring Earth Electrode in Progress of Time (코아링 접지전극의 경년변화 해석)

  • Oh, Seong-Bo;Kim, Se-Ho;Kim, Ho-Chan;Boo, Chang-Jin;Ahan, Jae-Hyun;Ko, Seoung-Min;Ko, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.89-90
    • /
    • 2006
  • Recent earth systems not only make earth resistance decreased by installing earth electrode but also are demanded by earth construction for the protection of human life and equipments through total investigation about circumstances. Layer constructions in Jeju island consist of multi-layer of scoria, rocks and shale except clay layers on the surface, which needs the construction of the coring earth electrode suitable in the condition of the area. For this reason, we've used the coring earth electrode. But the coring earth electrode is expected to slow down the performance of this equipment according to the progress of time changing the effects. It is also applied for the stability of earth system construction and management after the construction work analyzing the condition of the earth system. Therefore, this is actually focused on the analysis on measuring the earth resistance and the soil resistivity that cover the range where the remarkable contrast can be expected to be seen in the layer structures.

  • PDF

Delineation of Geological Weak Zones in an Area of Small-scale Landslides Using Correlation between Electrical Resistivity, Bore, and Well-logging Data (전기비저항 및 시추·검층자료의 상관해석을 통한 소규모 산사태 지역의 지질 연약대 파악)

  • Lee, Sun-Joong;Kang, Yu-Gyeong;Lee, Cheol-Hee;Jeon, Su-In;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.31-42
    • /
    • 2020
  • Electrical resistivity and downhole seismic surveys were conducted together with bore investigations and well-logging to examine subsurface structures in small-scale landslides at Sinjindo-ri, Geunheung-myeon, Taean-gun, Chungcheongnam-do, Republic of Korea in 2014. On the basis of the low N-values at depths of 5~7 m in borehole BH-2, downhole seismic and electrical dipole-dipole resistivity surveys were performed to delineate geological weak zones. The low-resistivity zones (<150 Ω·m) measure ~8 m in thickness and show a close depth correspondence to weathered soils consisting mainly of silty clays as identified from the bore investigations and well-logging data. Compared with weak zones in borehole BH-1, weak zones in BH-2 are characterized by lower densities (1.6~1.8 g/㎤) and resistivities (<150 Ω·m) and greater variation in Poisson's ratio. These observations can be explained by the presence of wet silty clays rich in weathered soil material that have resulted from heavy rainfall and rises in groundwater level. Downslope movements are probably caused by the sliding of wet clay that acts to reduce the strength of the weathered soil.

Study of geological structure in area of Hwasan caldera using geophysical method (지구물리학적 방법에 의한 화산 칼데라 지역의 지질구조 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Yang, Joon-Mo;Park, Gye-Soon;Eom, Joo-Young;Kim, Dong-Oh
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.267-272
    • /
    • 2007
  • Uiseong subbasin belonging to Kyungsang basin resulted from volcanic activity in the late Cretaceous. In this study, we carry out MT and gravity survey at the Hwasan caldera, which was formed of volcanic and abyssal rocks complex, then analyze and identify geological substructure. Potential survey such as gravity and magnetic survey has been mainly carried out in former studies, so depth information for understanding substructure was not enough. To complement a potential survey, we use MT method, which has high vertical resolution. Moreover we make a simple 2D model comparing with former study. The result of MT and gravity 2D modeling shows that this area is roughly composed of 3 layers; The bottom layer is a basement. In the second layer, intrusive rocks having high resistivity is placed along the ring faults and the sedimentary layer of low resistivity is inside caldera. The highest layer is alluvium. To comprehend the 3D structure of the Hwasan caldera, we perform 3D gravity inversion, and construct the 3D model from the result of 3D gravity inversion. MT responses are calculated by using the constructed 3D model and the 3D model of the Hwasan caldera's structure is suggested after comparing the calculated values with the observed values at MT line.

  • PDF

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

Industry-University-Research Collaborative Geoscientific Study in Pocheon Area for Groundwater Survey, Part III : Resistivity Technology (포천지역 지하수기초조사 산학연 공동탐사 사례연구(III): 전기탐사기술)

  • You, Young-June;Kim, Jong-Nam;Yoo, In-Kol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.129-136
    • /
    • 2005
  • The groundwater survey was carried out by electrical resistivity and resistivity tomography using several kinds of electrode array to delineate the depth of the saturated zone and basement complex, the aquifer system of fractured rock, and the 2-D resistivity structure was obtained by inversion technique. And the hole-to-surface and crosshole tomography were applied for two boreholes and the inverted resistivity tomogram are obtained. The comparison of those data with core logging data was performed and those results were relatively well correlated. And it was possible to find out the configuration of basement and the fracture zone and the aquifer system from the 2-D resistivity structure and resistivity tomogram.

  • PDF

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.