검색결과 425건 처리시간 0.033초

병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘 (The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line)

  • 이재규;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

퍼지추론 시스템을 이용한 지중송전계통 보호용 디지털 거리계전 알고리즘 개발 (Development of Digital Distance Relay Algorithm Using Fuzzy Inference System on Underground Power Cable Systems)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.502-503
    • /
    • 2006
  • If the fault occurs on the underground Power cable system, the fault current on the sheath has the influence on all sections because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) at joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current. Then the impedance between relaying point and fault point is Increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting of the underground power cable systems was developed. It effectively advance the errors using ACI(Advanced Computing Intelligence) technique. In this algorithm, the optimization was performed by fuzzy inference system and genetic algorithm.

  • PDF

Sediment-hosted gold mineralization of the Kyaukpahto mine, Kawlin Township, Myanmar

  • Swe, Ye-Myint;Min, A-Ung;Lee, In-Sung
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.315-315
    • /
    • 2003
  • Gold mineralization at Kyaukpahto occurs as stockworks/disseminations and locally as breccia zones in silicified sandstones of Lower to Middle Eocene Male Formation of Myanmar. The mineralization is spatially related with NNE -trending fracture zones_probably tensional open fractures caused by the right-lateral Sagaing fault system. Intensive silicification, sericitization, argillic alteration, sulfidation, and decalcification are recognized in the Kyaukpahto mine area. (omitted)

  • PDF

배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구 (A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems)

  • 김경철;정지원;이규진;이강수;최선규
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.113-119
    • /
    • 2010
  • 안전한 접지설계는 사고 시에 대지로 고장전류를 흘려보내는 수단과 인체가 사고기기에 접촉 시에 위험에 노출되지 않도록 하는데 있다. 변압기 중성점 접지는 1선 지락사고 시 중성점전위가 허용치 이하가 되도록 접지되어야 한다. 변압기 외함 접지는 절연사고로 외함에 전류가 흐를 때 인체 허용전압과 전류 이내로 저감시키는 목적으로 사용되고 있다. 본 논문에서는 사고 시 중성점 전위와 접촉전압을 계산하여 배전 변압기의 접지저항 영향을 심도있게 분석하였다.

현생 응력하에서 단층 마찰계수에 따른 임곡단층의 거동 가능성 해석 (Friction-dependent Slip Behavior of Imgok Fault under the Present-day Stress Field)

  • 나현우;장찬동;장천중
    • 지질공학
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2013
  • 강릉지역의 NNE-SSW 주향을 갖는 선형구조(임곡단층)를 대상으로, ASTER 영상과 항공사진을 이용한 구조 영상 분석과 야외지질조사를 통해 단층의 기하 및 운동학적 특성을 관찰하고 단층의 지질역학적 특성에 대한 분석을 시도하였다. 현생 응력장 하에서 임곡단층의 운동 가능성 여부를 파악하기 위해 이용된 주변 지진자료는 이 지역의 현생 최대응력방향이 약 N$70^{\circ}$E이며 주향이동과 역단층 운동에 유리한 응력상태임을 보여준다. 현생 응력장 하에서 임곡단층이 운동하기에는 최적의 방향에서 오차 범위 밖의 주향을 보여 전단 성향이 낮은 것으로 분석되었다. 그러나 단층의 역학적 특성을 나타내는 마찰계수(${\mu}$)가 상당히 낮을 경우(예를 들어 0.25 이하) 현생 응력장 하에서도 운동 가능성이 있는 것으로 파악된다.

직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단 (Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage)

  • 박제욱;백승원;김장목;이동춘;이교범
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.457-465
    • /
    • 2011
  • 본 논문에서는 3상 다이오드 정류기의 고장에 따른 해석 및 고장 판별 기법을 제안한다. 입력전원이나 다이오드소자에 고장이 발생하게 되면 출력 직류단 전압에 큰 맥동을 유발하며 이는 인버터 시스템의 제어 성능을 저하시킬 뿐만 아니라 커패시터의 수명 단축을 야기한다. 본 논문에서는 입력측의 지락 사고 및 다이오드 개방 사고 시의 직류단 전압 특성을 분석하고, 계통주파수의 6배에 주파수마다 측정된 직류단의 순시전압을 직류단 평균 전압과 비교함으로서 고장의 유무 및 종류를 판별하는 알고리즘을 제안하였다. 제안한 알고리즘은 직류단 전압 센서만을 이용하므로 구현이 간단하고 고장 진단을 위한 추가적인 하드웨어가 요구되지 않는다. 실험과 시뮬레이션을 통해 제안한 고장 진단 알고리즘의 타당성을 검증하였다.

원격탐사자료와 수치표고모형을 이용한 옥천대 남서경계부의 선구조 분석 연구 (A Study on the Lineament Analysis Along Southwestern Boundary of Okcheon Zone Using the Remote Sensing and DEM Data)

  • 김원균;이윤수;원중선;민경덕;이영훈
    • 자원환경지질
    • /
    • 제30권5호
    • /
    • pp.459-467
    • /
    • 1997
  • In order to examine the primary trends and characteristics of geological lineaments along the southwestern boundary of Okcheon zone, we carried out the analysis of geological lineament trends over six selected sub-areas using Landsat-5 TM images and digital elevation model. The trends of lineaments is determined by a minimum variance method, and the resulting geological lineament map can be obtained through generalized Hough transform. We have corrected look direction biases reduces the interpretability of remotely sensed image. An approach of histogram modification is also adopted to extract drainage pattern specifically in alluvial plains. The lineament extracting method adopted in this study is very effective to analyze geological lineaments, and that helps estimate geological trends associated various with the tectonic events. In six sub-areas, the general trends of lineaments are characterized NW, NNW, NS-NNE, and NE directions. NW trends in Cretaceous volcanic rocks and Jurassic granite areas may represent tension joints that developed by rejuvenated end of the Early Cretaceous left-lateral strike-slip motion along the Honam Shear Zone, while NE and NS-NNE trends correspond to fault directions which are parallel to the above Shear Zone. NE and NW trends in Granitic Gneiss are parallel to the direction of schitosity, and NS-NNE and NE trends are interpreted the lineation by compressive force which acted by right-lateral strike-slip fault from late Triassic to Jurassic. And in foliated Granite, NE and NNE trends are coincided with directions of ductile foliation and Honam Shear Zone, and NW-NNW trends may be interpreted direction of another compressional foliation (Triassic to Early Jurassic) or end of the Early Cretaceous tensional joints. We interpreted NS-NNE direction lineation is related with the rejuvenated Chugaryung Fault System.

  • PDF

혼합송전계통에서 고장구간에 따른 병행지선 설치효과 검토 (Analysis of Earth Continuity Conductor Installation Effect According to Fault Section in Combined Transmission Systems)

  • 강지원;정채균;박흥석;장태인;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.110-112
    • /
    • 2008
  • This paper describes the effects of earth continuity conductor for reducing the level of induced sheath overvoltage at the single point bonded section of combined transmission systems. Firstly, 3 kinds of fault section are considered, and also faulty phases and the distance between phase conductor and earth continuity conductor are changed for the various analysis.

  • PDF

서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준 (A Study on the Unification of The Grounding System of SeoulMetro due to Ageing)

  • 민병훈;김균식;정용기
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.394-400
    • /
    • 2006
  • Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.

Geochemistry for the Serpentinites of the Igneous and Metamorphic Origins

  • Song, Suck-Hwan;Park, Seong-Gyu;Oh, Chang-Whan;Seo, Ji-Eun
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.196-197
    • /
    • 2003
  • Several masses of the alpine type ultramafic rocks are found within the Precambrian Kyeonggi gneiss complex, western part of Chungnam province. They occur as discontinuous isolated lenticular bodies along the fault line(NNE direction), dominant tectonic directions of Kyeonggi gneiss complex. The ultramafic rocks occur as fault contacts with the adjacent Precambrian metamorphic and metasedimentary rocks. (omitted)

  • PDF