• Title/Summary/Keyword: Early Fixation

Search Result 209, Processing Time 0.04 seconds

Initial Fixation Power of Human Bone Interference Screw (인간 골 간섭 나사못의 초기 고정력)

  • Kim Jung-Man;Chung Yang-Kook;Kim Yang-Soo;Oh In-Soo;Koh Ihn-Joon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 2002
  • Purpose: To estimate the initial and early phase fixation power of the human bone interference screw in reconstruction of the anterior cruciate ligament with bone-patellar tendon-bone allograft. Materials and Methods: The results of twenty eight knees of reconstruction with bone-patellar tendon-bone allograft were analysed in 6 weeks, 12 weeks, 6 months and one year following operation. Physical examination including Lachman test, flexion rotation drawer test and jerk test were performed. The KT-1000 measurement was performed at the same time. In Lachman test 0 $\~$2mm anterior displacement of the tibia was considered normal. The KT-1000 measurement of normal side was compared with operation side and the difference of the two was recorded. The MRI was checked at final follow-up. Results: All but one knee showed normal in physical examination. The failed case showed proximal migration of the graft due to insufficient number of interference screw fixation in widened tibial tunnel. Conclusions: The human cortical bone interference screw showed sufficient initial and early phase fixation power in reconstruction of the anterior cruciate ligament.

  • PDF

Clinical Outcomes of Anterior Open Reduction and Posterior Percutaneous Screw Fixation for Displaced Talar neck Fractures (전방 정복술 및 경피적 후방 압박나사 내고정술을 이용한 전위성 거골 경부 골절의 치료 결과)

  • Park, Ji-Kang;Kim, Yong-Min;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Cha, Jung-Kwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.106-114
    • /
    • 2013
  • Purpose: Posteroanterior screw fixation is biomechanically stronger than anteroposterior screw fixation. However, there are few literature about the correlation between clinical results and more strength by posteroanterior fixation. This study was performed to evaluate the clinical outcomes of the accelerated rehabilitation following anterior open reduction and posterior percutaneous screw fixation for displaced talar neck fractures. Materials and Methods: Eighteen cases were followed up for more than 1 year after posteroanterior fixation using headless compression screw for talar neck fractures. The clinical evaluation was performed according to American Orthopaedic Foot and Ankle Society (AOFAS) score and Hawkins criteria. As radiographic evaluation, the degree of fracture displacement, period to union, and occurrence rate of complications such as avascular necrosis through MRI were measured. Results: The AOFAS score was average 90.4 points at the last follow-up. There were 7 excellent, 9 good, and 2 fair results according to the Hawkins criteria. Therefore, 16 cases(88.8%) achieved satisfactory results. The degree of fracture displacement had improved significantly from preoperative average 5.6 mm to 1.2 mm immediate postoperatively, and maintained to 1.1mm at the last follow-up. All cases achieved bone union, and the period to union was average 12.4 weeks. There were 3 cases of avascular necrosis of talar body and 2 cases of post-traumatic arthritis. Conclusion: Anterior open reduction and posterior percutaneous headless screw fixation seems to be an effective surgical method for displaced talar neck fractures, because of the possibility of accurate restoration of articular surface, fixation strength enough to early rehabilitation, and needlessness of hardware removal.

Biomechanical Effects of Facet Capsule Injuries in Posterior Lumbar Fusion Operations (후방경유 요추 융합수술시 척추후관절낭 손상의 운동역학적 영향)

  • Park, Seung Won;Kim, Young Baeg;Hwang, Sung Nam;Choi, Duck Young;Kwon, Jeong Taik;Min, Byung Kook;Suk, Jong Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.358-365
    • /
    • 2001
  • Objectives : Although posterior lumbar fusion operations had been reported to accelerate spinal degeneration, there have been only a few studies for their biomechanical effects. We have studied the change of motion range at the vertebral joint one level above the fusion(UVJ) in pedicle screw fixation group(PSF)(n=13) where facet capsule was destroyed and in posterior lumbar interbody fusion group(PLIF)(n=8) where it was spared. Patients and Methods : The patients were divided into early(3 to 6 months) and late(over 12 months) according to postoperative follow-up period. The flexion, extension and flexion-extension angles(FA, EA, FEA) were measured at the UVJ with pre-operative, early and late post-operative films. Results : Mean age and male to female ratio were $52.7{\pm}9.3$ and 1 : 3.2. Mean follow-up periods were $144.1{\pm}30.0$ and $528.8{\pm}160.3$ days in early and late groups, respectively. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than pre-operative angles($7.8{\pm}3.9$, $5.1{\pm}3.7$)(p<0.01, p<0.05). All angles in the PLIF showed no significant changes with time. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than those of the late PLIF($7.6{\pm}2.3$, $3.4{\pm}2.0$)(p<0.01, p<0.001). All angles at early follow-up period were similar between PSF and PLIF. The EA showed no significant change in relation with follow-up period or fusion method. Conclusion : As a result, the facet capsule injury in pedicle screw fixation seems to be related with increased flexion angle or degeneration of the adjacent joint above the fused vertebra in the late phase.

  • PDF

Biepicondylar Fracture of the Humerus in an Adult Female: A Case Report

  • Seong, Minkyu;Choi, Jungyun;Yum, Jaekwang
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.249-251
    • /
    • 2016
  • iepicondylar fracture of the humerus is very rare in adults. To date, there have been limited evidence of this injury in the English literature. We report a case of a 65-year-old female with a biepicondylar fracture of the left distal humerus without dislocation. Open reduction and internal fixation with K-wires, cannulated screw, and suture anchor were performed. We obtained stability of the elbow and a satisfactory functional outcome. Because this type of injury is associated with varus and valgus instability, operative reduction and fixation are essential in order to gain stability and early recovery of normal function.

TREATMENTS OF COMMINUTED MANDIBULAR FRACTURES (하악골 분쇄골절의 치료)

  • Jeon, Woo-Jin;Kim, Su-Gwan;Kim, Hyeon-Ho;Kim, Hak-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.71-75
    • /
    • 2005
  • This study evaluated retrospectively the treatment method and postoperative complications of communited mandibular fractures. We analyzed the clinical and radiologic data of 14 patients with the comminuted mandibular fractures who were admitted to Chosun University Dental Hospital from January 1998 to December 2003. We reviewed the cause of trauma, fracture sites, treatment methods, and postoperative complications. Thirteen patients (93%) had a successful treatment outcome without complications. Only one patient developed postoperative osteomyelitis requiring early plate removal and sequestrectomy. For the comminuted fractures of mandible, internal fixation using micro- or mini-plate was an effective treatment method with a low incidence of major complications.

Simulation analysis of Transporting Fixation Equipment on Unit Module (유닛모듈 운반을 위한 고정장치의 시뮬레이션 분석)

  • Park, Su-Yeul;Kim, Kyoon-Tai;Park, Nam-Cheon;Chae, Myung-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.143-144
    • /
    • 2013
  • Unit module system produce units in the factory and assemble in the field. This unit module system has advantages of shortening the process of construction. However, it is still in the early research related to setting the unit module which is transported by truck to the field. Therefore, when transporting the unit module, this goal of study develops fixed devices. And suggesting device were performed that simulations analyzed maximum stress and assessed the safety.

  • PDF

Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia (삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법)

  • Lee, Kee-Byoung;Chang, Ho-Guen;Lee, Seok-Beom;Moon, Young-Wan;Kang, Ki-Hoon;Lee, Wook-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Avulsion fractures of the intercondylar eminence of the tibia are not uncommon. In the displaced avulsion fracture, anatomical reduction and firm fixation of fracture fragments are needed but the most of the conventional operative techniques including arthroscopic technique are relatively complex and need. The results were not always satisfactory due to the risk of postoperative complications such as wound infection, premature epiphyseal closure and loss of fixation after early motion etc. So we describe a simple and safe modified method of arthroscopic reduction and fixation for avulsion fractures of the intercondylar eminence of the tibia. In our thirteen cases, we achieved anatomical reduction and secure fixation using cannulated screw through the three arthroscopic portals (anterolateral, medial mid-patellar and central). Postoperatively, immediate limited range of motion of the knee and partial weight bearing were possible. Additional use of the washer afforded safe fixation of comminuted avulsion fracture. The advantage of this technique includes its technical simplicity, easy removal of hardware, ability to treat comminuted type IV fracture with washer, no additional skin incision, no damage to growing plate in growth children and less morbidity.

  • PDF

Arthroscopic Treatment of Fractures of the Intercondylar Eminence of the Tibia Using Pull-Out Wire (견인강선을 이용한 경골극 견열 골절의 관절경적 치료)

  • Kim, Hyun Kon;Kim, Sung Jae;Hahn, Myung Hoon;Kang, Yong Ho;Jung, Hwan Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Recently, a variety of arthroscopic techniques have been reported for the treatment of the displaced tibial eminence fracture. The purpose of this study was to describe details of arthroscopic technique using pull-out wire and to evaluate the results. Eleven patients with irreducible type II and type III tibial eminence fractures underwent the arthroscopic reduction and internal fixation using double strand pull-out wiring. The anterior cruciate ligament tibial drill guide was utilized for the reduction of fracture and passage of the guide pins. The tibial eminence fracture was firmly fixed with double strand 26-gauge pull-out wire(0.45mm diameter). Fracture union was achieved at 7.2 weeks (range, six to eight weeks) after operation. All cases were united at the last follow-up. Subjectively, nine patients had no pain and no restriction of daily activities. Two patients with combined injuries had limitation of knee motion(10 to 130 degrees, respectively) and one patient showed mild anterior laxity. Early rehabilitation was enabled without loss of reduction and breakage of pull-out wire. The arthroscopic reduction and internal fixation using pull-out wire showed good results including early rehabilitation, early fracture union, minimal morbidity, and no requirement of the second operation for hard ware removal.

  • PDF

The Timing of Femur Fracture Fixation is an Important Factor for Prolonged Mechanical Ventilation

  • Choi, Hyung Chul;Jung, Kwang Hwan;Kyoung, Kyu Hyouck;Choi, Seong Ho
    • Journal of Trauma and Injury
    • /
    • v.32 no.4
    • /
    • pp.220-225
    • /
    • 2019
  • Purpose: Mechanical ventilation (MV) is an essential life-saving modality for severely injured patients. However, the long-term use of MV is a major risk factor for late mortality. The surgical correction of long bone fractures plays a critical role not only in improving functional outcomes, but also in reducing physiological derangements, including MV duration. This study investigated the factors affecting prolonged MV (PMV) in severely injured patients with femur fractures. Methods: We retrospectively evaluated all severely injured patients (injury severity score >15) with femur fractures who were taken to the emergency department within 12 hours of the causative accidents between January 2016 and December 2018. PMV was defined as MV lasting for ≥7 days. We analyzed the factors affecting PMV. Results: In total, 35 patients were enrolled and 21 (33.3%) were included in the PMV group. The PMV group required more red blood cell (RBC) transfusions within 7 days RBC (7dRBC) (12.8 vs. 6.8 units; p=0.03) and the time to femur fracture fixation (TFFF) was longer (7.9 vs. 2.7 days; p=0.018). The area under the curve (AUC) for TFFF was 0.740 (95% confidence interval [CI]: 0.572-0.908; p=0.018) and the AUC for 7dRBC was 0.718 (95% CI: 0.546-0.889; p=0.031). Conclusions: This study indicates that TFFF is an independent risk factor for PMV. Early fixation of femur fractures might prevent PMV and its associated complications.

All-arthroscopic, Guideless Single Suture-button Fixation of Acute Acromioclavicular Joint Dislocation: A Description of the Technique and Early Treatment Results

  • Altintas, Burak;Yildiz, Fatih;Uzer, Gokcer;Kapicioglu, Mehmet;Bilsel, Kerem
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2017
  • Background: The purpose of this study was to examine the clinical and radiological results of the all-arthroscopic, suture-button fixation technique to treat acute acromioclavicular (AC) joint separations. Methods: All patients with acute AC joint separations received all-arthroscopic, single suture-button (TightRope) procedure without a special guide. Postoperative Constant score (CS), pain level according to visual analogue scale, and range of motion (ROM) were evaluated. For radiological evaluation, coracoclavicular distances were measured bilaterally. Results: Between December 2010 and June 2012, 18 consecutive patients (4 women and 14 men; mean age, 29.3 years) with acute AC joint separations underwent surgical treatment after 6.4 days (range, 2-20 days) following the initial trauma. The average postoperative follow-up was 16.9 months. The mean CS was 92.4 (range, 84-96). The mean external rotation, forward flexion, and abduction were $75.8^{\circ}$ (range, $50^{\circ}-90^{\circ}$), $170^{\circ}$ (range, $150^{\circ}-180^{\circ}$), and $163.8^{\circ}$ (range, $140^{\circ}-180^{\circ}$), respectively. Five patients exhibited coracoclavicular ossifications. In two patients, superficial wound infections were successfully treated with antibiotic therapy. In one patient, a coracoid fracture was observed. No significant differences were found regarding pain, ROM, or strength parameters between both sides. The coracoclavicular distance was discovered to be approximately 2.8 mm greater on the affected side; however, this minimal reduction loss did not affect the functional results. Conclusions: The findings of this study suggests that all-arthroscopic treatment of AC joint separations using the single suture-button technique without a drill guide is safe, yielding good to excellent clinical results.