• Title/Summary/Keyword: EXPOSURE

Search Result 15,168, Processing Time 0.036 seconds

THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST (Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구)

  • Yoo Young Sun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

VIBRATION ANALYSIS OF PCB MANUFACTURING SYSTEM USING MASKLESS EXPOSURE METHOD (Maskless 방식을 이용한 PCB 생산시스템의 진동 해석)

  • Jang, Won-Hyuk;Lee, Jae-Mun;Cho, Myeong-Woo;Kim, Joung-Su;Lee, Chul-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.421-426
    • /
    • 2009
  • This paper presents vibration analysis of maskless exposure module in Printed Circuit Board (PCB) manufacturing system. In order to complete exposure process in PCB, masking type module has been widely used in electronics industries. However, masking process confronts some limitations of application due to higher production cost for masking as well as lower printing resolution. Therefore, maskless exposure module is started to be in the spotlight for flexible production system to meet the needs of fabrication in variable patterns at low cost. Since maskless exposure process adopts direct patterning to PCB, vibration problems become more critical compared to conventional masking type process. Moreover, movements of exposure engine as well as stage generate vibration sources in the system. Thus, it is imperative to analyze the vibration characteristics for the maskless exposure module to improve the quality and accuracy of PCB. In this study, vibration analysis using the Finite Element Analysis is conducted to identify the critical structural parts deteriorating vibration performance. Also, Experimental investigations are conducted by single/dual encoder measurement process under the operating module speed. Measurement points of vibration are selected by three places, which are base of stage, exposure engine and top of stage, to check the effect of vibration from the exposure engine. Comparisons between analysis results and experimental measurement are conducted to confirm the accuracy of analysis results including the developed FE model. Finally, this studies show feasibility of optimal design using the developed FE analysis model.

  • PDF

The Effect of e-PTFE Membrane Exposure on the Initial Healing of Periodontal Tissue in GTR Procedure (e-PTFE 차단막을 이용한 조직유도재생술시 e-PTFE 차단막의 노출이 치주조직의 초기치유에 미치는 영향)

  • Moon, Ik-Sang;Kim, Ji-Eun;Song, Kun-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.553-560
    • /
    • 1999
  • The aim of the present study was to evaluate the effect of the expanded polytetrafluoroethylene (e-PTFE) membrane exposure on the initial healing of the periodontal tissue in guided tissue regeneration (GTR) procedure. 90 sites selected from 90 patients were treated with gingival flap surgery supported by an e-PTFE membrane. The material included angular bony defects with probing attachment loss of > 5mm or degree II furcation involvement. Treated sites were classified with membrane exposure group and non-exposure group at membrane removal and evaluated healing type. The results were obtained as follows. 1. e-PTFE membrane was exposed at 61 sites (67.8%) among 90 sites. 2. Thirteen sites (14.4%) depicted rapid healing type, 65 sites (72.2%) depicted typical healing type, 9 sites (10%) showed delayed healing type and 3 sites (3.3%) were categorized as adversed healing type. 3. In e-PTFE membrane exposure group, 1 site (1.6%), 51 sites (83.6%), 6 sites (9.8%) and 3 sites (4.9%) showed rapid healing type, typical healing type, delayed healing type and adverse healing type respectively. 4. In e-PTFE membrane non-exposure group, 12 sites (41.3%), 14 sites (48.3%) and 3 sites (10.3%) showed rapid healing type, typical healing type and delayed healing type respectively. Adverse healing type was not observed. 5. The rate of favourable healing between e-PTFE membrane exposure group and non-exposure group was not statistically significant(p=0.56). These results suggest that the prevention of membrane exposure may be important to obtain rapid healing type. However favourable healing could be obtained with stringent infection control program even if membrane was exposed.

  • PDF

A Critical Evaluation of DNA Adducts as Biological Markers for Human Exposure to Polycyclic Aromatic Compounds

  • Godschalk, Roger W.L.;Van Schooten, Frederik-Jan;Bartsch, Helmut
    • BMB Reports
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • The causative role of polycyclic aromatic hydrocarbons (PAH) in human carcinogenesis is undisputed. Measurements of PAH-DNA adduct levels in easily accessible white blood cells therefore represent useful early endpoints in exposure intervention of chemoprevention studies. The successful applicability of DNA adducts as early endpoints depends on several criteria:i.adduct levels in easily accessible surrogate tissues should reflect adduct levels in target-tissues, ii. toxicokinetics and the temporal relevance should be properly defined.iii. sources of inter- and intra-individual variability must be known and controllable, and finally iv. adduct analyses must have advantages as compared to other markers of PAH-exposure. In general, higher DNA adduct levels or a higher proportion of subjects with detectable DNA adduct levels were found in exposed individuals as compared with non-exposed subjects, but saturation may occur at high exposures. Furthermore, DNA adduct levels varied according to changes in exposure, for example smoking cessation resulted in lower DNA adduct levels and adduct levels paralleled seasonal variations of air-pollution. Intra-individual variation during continuous exposure was low over a short period of time (weeks), but varied significantly when longer time periods (months) were investigated. Inter-individual variation is currently only partly explained by genetic polymorphisms in genes involved in PAH-metabolism and deserves further investigation. DNA adduct measurement may have three advantages over traditional exposure assessment: i. they can smooth the extreme variability in exposure which is typical for environmental toxicants and may integrate exposure over a longer period of time. Therefore, DNA adduct assessment may reduce the monitoring effort. ii. Biological monitoring of DNA adducts accounts for all exposure routes. iii. DNA adducts may account for inter-individual differences in uptake, elimination, distribution, metabolism and repair amongst exposed individuals. In conclusion, there is now a sufficiently large scientific basis to justify the application of DNA adduct measurement as biomarkers in exposure assessment and intervention studies. Their use in risk-assessment, however, requires further investigation.

BENZENE AND LEUKEMIA An Epidemiologic Risk Assessment

  • Rinsky Robert A.;Smith Alexander B.;Hornung Richard;Filloon Thomas G.;Young Ronald J.;Okun Andrea H.;Landrigan Philip J.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.651-657
    • /
    • 1994
  • To assess quantitatively the association between benzene exposure and leukemia, we examined the mortality rate of a cohort with occupational exposure to benzene. Cumulative exposure for each cohort member was estimated from historical air-sampling data and, when no sampling data existed, from interpolation on the basis of existing data. The overall standardized mortality ratio (a measure of relative risk multiplied by 100) for leukemia was 337 (95 percent confidence interval, 154 to 641), and that for multiple myeloma was 409 (95 percent confidence interval, 110 to 1047). With stratification according to levels of cumulative exposure, the standardized mortality ratios for leukemia increased from 109 to 322, 1186, and 6637 with increases in cumulative benzene exposure from less than 40 parts per million-years (ppm-years), to 40 to 199, 200 to 399, and 400 or more. respectively. A cumulative benzene exposure of 400 ppm years is equivalent to a mean annual exposure of 10 ppm over a 40-year working lifetime; 10 ppm is the currently enforceable standard in the United States for occupational exposure to benzene. To examine the shape of the exposure-response relation, we performed a conditional logistic-regression analysis, in which 10 controls were matched to each cohort member with leukemia. From this model, it can be calculated that protection from benzene induced leukemia would increase exponentially with any reduction in the permissible exposure limit.

  • PDF

Serum 2,3,7,8-Tetrachlorodibenzo-p-dioxin Levels and Their Association With Age, Body Mass Index, Smoking, Military Record-based Variables, and Estimated Exposure to Agent Orange in Korean Vietnam Veterans

  • Yi, Sang-Wook;Ohrr, Heechoul;Won, Jong-Uk;Song, Jae-Seok;Hong, Jae-Seok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.5
    • /
    • pp.226-236
    • /
    • 2013
  • Objectives: The aim of this study was to examine the levels of serum 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and evaluate their association with age, body mass index, smoking, military record-based variables, and estimated exposure to Agent Orange in Korean Vietnam veterans. Methods: Serum levels of TCDD were analyzed in 102 Vietnam veterans. Information on age, body mass index, and smoking status were obtained from a self-reported questionnaire. The perceived exposure was assessed by a 6-item questionnaire. Two proximitybased exposures were constructed by division/brigade level and battalion/company level unit information using the Stellman exposure opportunity index model. Results: The mean and median of serum TCDD levels was 1.2 parts per trillion (ppt) and 0.9 ppt, respectively. Only 2 Vietnam veterans had elevated levels of TCDD (>10 ppt). The levels of TCDD did not tend to increase with the likelihood of exposure to Agent Orange, as estimated from either proximity-based exposure or perceived self-reported exposure. The serum TCDD levels were not significantly different according to military unit, year of first deployment, duration of deployment, military rank, age, body mass index, and smoking status. Conclusions: The average serum TCDD levels in the Korean Vietnam veterans were lower than those reported for other occupationally or environmentally exposed groups and US Vietnam veterans, and their use as an objective marker of Agent Orange exposure may have some limitations. The unit of deployment, duration of deployment, year of first deployment, military rank, perceived self-reported exposure, and proximity-based exposure to Agent Orange were not associated with TCDD levels in Korean Vietnam veterans. Age, body mass index and smoking also were not associated with TCDD levels.

Risk Assessment of Baby Powder Exposure through Inhalation

  • Moon, Min-Chaul;Park, Jung-Duck;Choi, Byung-Soon;Park, So-Young;Kim, Dong-Won;Chung, Yong-Hyun;Hisanaga, Naomi;Yu, Il-Je
    • Toxicological Research
    • /
    • v.27 no.3
    • /
    • pp.137-141
    • /
    • 2011
  • This study was conducted to assess the exposure risk through inhalation to baby powder for babies and adults under simulated conditions. Baby powder was applied to a baby doll and the amount of baby powder consumed per application was estimated. The airborne exposure to baby powder during application was then evaluated by sampling the airborne baby powder near the breathing zones of both the baby doll and the person applying the powder (the applicator). The average amount of baby powder consumed was 100 mg/application, and the average exposure concentration of airborne baby powder for the applicator and baby doll was 0.00527 mg/$m^3$ (range 0.00157~0.01579 mg/$m^3$) and 0.02207 mg/$m^3$ (range 0.00780~0.04173 mg/$m^3$), respectively. When compared with the Occupational Exposure Limit of 2 mg/$m^3$ set by the Korean Ministry of Labor and the Threshold Limit Value (TLV) of 2 mg/$m^3$ set by the ACGIH (American Conference of Governmental Industrial Hygienists), the exposure concentrations were much lower. Next, the exposure to asbestos-containing baby powder was estimated and the exposure risk was assessed based on the lung asbestos contents in normal humans. As a result, the estimated lung asbestos content resulting from exposure to asbestos-containing baby powder was found to be much lower than that of a normal Korean with no asbestos-related occupational history.

The Study to ETS Exposure and Their Biomarkers in Hair of Restaurant Workers (식당 종업원의 환경 담배 연기(ETS)의 노출과 머리카락 중 생체지표 연구)

  • Jo Seong-Joon
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.169-176
    • /
    • 2004
  • ETS (environmental tobacco smoke) is composed of exhaled mainstream smoke (MS) from the smoker, sidestream smoke (SS) emitted from the smoldering tobacco between puffs and contaminants that diffuse through the cigarette paper and mouth between puffs. These emissions contain both vapor phase and particulate contaminants. ETS is a complex mix of over 4,000 compounds. This mix contains many known or suspected human carcinogens and other toxic agents. More of these toxic compounds are found in SS than in MS. Workplace exposure to ETS can result in significant smoke intake, and passive smoke exposure may be related to impair respiratory function and an increase risk of lung cancer in nonsmokers. For nonsmokers sharing a work environment with cigarette smokers, the workplace must be considered hazardous independently of any specific industrial toxic exposure. The risk is particularly important when a high percentage of the workers smoke or where smokers and nonsmokers work in poorly ventilated areas. Nicotine is converted in the body to cotinine; cotinine therefore can be used as an indirect measure of a person's recent exposure to tobacco smoke. Levels of nicotine in hair and levels of cotinine in body fluids (saliva and urine) have been shown to increase with increasing environmental nicotine levels and with self-reported ETS exposure. The measurement of nicotine or cotinine in hair may be more appropriate for longer-term exposure to tobacco. The purpose of this study is to comparing airborne nicotine levels and hair cotinine level in restaurant workers. Concentration of airborne nicotine and hair nicotine (and cotinine) is closely related to exposed frequency of sidestream smoke in the workplace. Nicotine in hair is a better predictor of airborne nicotine than hair cotinine. Hair nicotine can be a useful tool to assess ETS exposure interventions. It may have limiting levels of ETS exposure by placing regulatory restrictions on smoking in workplaces and in public spaces.

Validation of a Rodent Nose-only Exposure System for Inhalation Toxicity Evaluation of Cigarette Smoke (담배 흡입독성 평가를 위한 설치류 담배연기노출시스템의 유효화)

  • Sohn, Hyung-Ok;Lee, Hyeong-Seok;Shin, Han-Jae;Park, Chul-Hoon;Yoo, Ji-Hye;Jang, Mi;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • As part of a balanced testing battery, subchronic inhalation studies on rats are performed to ensure that proposed cigarette modifications do not increase the toxicity of smoke and to demonstrate any instances where a modification may actually contribute to harm reduction. For subchronic inhalation studies with aerosols, the OECD suggests an exposure regimen of 6 hours/day (OECD Guideline 413, 1981), but alternative regimens have also been published: 1 hour/day and $2{\times}1$ hour/day. The aim of this study was to validate a rodent nose-only exposure system for the assessment of inhalation toxicity of cigarette smoke. In this study, cigarette smoke exposure system is consisted of cigarette smoke generator, smoke concentration adjusting system, and 20-port nose-only exposure system. Male SD rats were exposed for 35 days ($2{\times}1$ hour/day) to 3R4F Reference cigarette smoke and analysed major monitoring items of OECD Gudeline 413. WTPM, was measured in the test atmosphere, respiratory function (Buxco Biosystems) during exposure, postexposure urinary exposure biomarkers and alveolar neutrophiles in BAL fluid (Day 35) were evaluated. Validation demonstrated steady WTPM ($257{\pm}20ug/L$, $502{\pm}27ug/L$) and spatial uniformity (<10%). Nose port temperature ($22{\sim}26^{\circ}C$ and RH (45~75%) were acceptable over 35 days. Reductions in respiratory rate and minute volume and increase in the neutrophiles in BALF and the urinary exposure biomarkers were observed cigarette smoke dose dependently. This validation and 35-day inhalation study has shown that the rodent nose-only exposure system may be useful in the inhalation toxicity assessment of cigarette smoke.

Record Keeping of Employee Exposure to Chemical Hazards under Industrial Safety and Health Law (근로자의 화학물질 노출관련 기록 보존에 관한 연구)

  • Oh, Sangmin;Park, Donguk;Yu, SeoungJae;Jung, Jin Woo;Lim, KyungTaek;Lee, Jaehwan;Ha, Kwonchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.367-373
    • /
    • 2013
  • Objectives: Employee exposure record refers to a record containing information about environmental (workplace) monitoring or measuring of a toxic substance or harmful physical agent. The aims of this study were to examine problems related to exposure records and provide some amendments to the Korean Industrial Safety & Health Act for the effective management of chemical substances under the law. Methods: This study performed a literature search and review on legal provisions related to exposure records of a number of different countries, including Korea, the USA, Japan, EU, Germany, and the UK. They were compared and investigated and the amendment of articles was suggested. Results: The results of this study were provided as suggested amendments to the related act. There were a variety of ways of improvement, including a 30-year retention period and the introduction of new access methods, contents, transfer, and maintenance methods. All exposure data elements have to be standardized, including reference to a similar exposure group (SEG), sampling strategy, and circumstances of exposure (e.g., date, shift length, use of personal protective equipment, etc.). The SEGs are described by process, job, task, and environmental agent. Conclusions: This study is expected to provide for the amendment of the related act in order to ensure effective management of exposure records and is helpful for solving the cause and result of occupational disease by keeping exposure records according to the Industrial Safety & Health Act.