• 제목/요약/키워드: EVAPORATION

검색결과 3,553건 처리시간 0.03초

전기선폭발법에 의해 카본 코팅된 Cu 나노분말의 제조 및 특성 연구 (Fabrication and Characterization of Carbon-Coated Cu Nanopowders by Pulsed Wire Evaporation Method)

  • 이희민;박중학;홍성모;엄영랑;이창규
    • 한국분말재료학회지
    • /
    • 제16권4호
    • /
    • pp.243-248
    • /
    • 2009
  • Carbon-coated Cu nanopowders with core/shell structure have been successfully fabricated by pulsed wire evaporation (PWE) method, in which a mixed gas of Ar/$CH_4$ (10 vol.%) was used as an ambient gas. The characterization of the samples was carried out using x-ray diffraction (XRD), scanning electron microscope (SEM), and high resolution transmission electron microscope (HRTEM). It was found that the nanoparticles show a spherical morphology with the size ranging of 10-40 nm and are covered with graphite layers of 2-4 nm. When oxygen-passivated Cu nanopowders were annealed under flowing argon gas (600 and 800$^{\circ}C$), the crystallinity of $Cu_2O$ phase and the particle size gradually increased. On the other hand, carbon-coated Cu nanopowders remained similar to as-prepared case with no additional oxide or carbide phases even after the annealing, indicating that the metal nanoparticles are well protected by the carbon-coating layers.

유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구 (A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner)

  • 강정길;김종수
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

LTCC 슬러리 및 그린시트의 물성 변화에 미치는 혼합용매 조성의 영향 (Effect of Solvent Mixture on the Properties of LTCC Slurry and Green Sheets)

  • 조범준;박은태
    • 한국재료학회지
    • /
    • 제16권9호
    • /
    • pp.533-537
    • /
    • 2006
  • The effects of binary solvent mixtures with various ratios of toluene and ethanol on the properties of slurries and green sheets were investigated. Viscosity of slurry was changed by varying the ratio of solvent mixture which affected the solubility of binder. The relative solvency behavior of a solvent mixture could be predicted with the Hildebrand solubility parameter(${\delta}$) and hydrogen bonding index( ${\gamma}$). The minimum viscosity, the best dispersion of binder, was reached at the composition of toluene:ethanol=4:6, which corresponded to our forecast. The mechanical properties of green sheets related to evaporation of solvents were influenced by the composition of the solvent mixture. At the azeotrope the skin was formed on a drying cast during the drying process because of fast evaporation. At a range of concentrations over 50wt% toluene, green sheets could not be fully dried at low temperature due to excessive toluene. The mechanical properties of green sheets were excellent at the azeotrope-like composition of toluene:ethanol=4:6 which has a little excess of toluene over the azeotrope.

군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구 (The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space)

  • 이진호;방창훈;김정수
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

최적 증착 속도로 형성된 MgO를 갖는 인-라인 진공 실장된 플라즈마 디스플레이 패널의 방전 특성에 관한 연구 (A Study on Discharge Characteristics of the PDP Packaged with In-situ Vacuum Sealing with the MgO Protective Layer Deposited by Optimal Evaporation Rate)

  • 이조휘;조의식;권상직
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.916-922
    • /
    • 2008
  • AC PDP with MgO protective layer coated with the optimum evaporation rate of $5{\AA}/s$ can generate more enhanced efficiency through the vacuum in-line sealing process. However, the optimized process conditions still require the optimum driving scheme on the ramp-up and ramp-down slope of the reset waveform for enhancing the efficiency. In this paper, for the in-situ vacuum sealed PDP with the optimum evaporation rate of MgO protective layer, the address delay time was investigated with various slopes of ramp waveform during a reset ramp-up and ramp-down period. In this study, the minimum statistical delay time was obtained at the ramp-up rate of $6.0 V/{\mu}s$ and the ramp-down rate of $0.7 V/{\mu}s$ of the reset waveform.

포트분사식 이륜차 엔진의 연료 분사시기에 따른 연료 증발 특성 (Fuel Evaporation Characteristics of a Port Injection Type Motorcycle Engine with Changing Fuel Spray Timing)

  • 이기형;강인보;김형민;백승국
    • 대한기계학회논문집B
    • /
    • 제29권12호
    • /
    • pp.1360-1368
    • /
    • 2005
  • This study investigates the characteristics of spray, such as evaporation rate and spray trajectory, for a 4-hole injector which is applied to a 4-valve motorcycle gasoline engine. Three dimensional, unsteady, compressible flow and spray within the intake-port and cylinder have been simulated using the VECTIS code. Spray characteristics were investigated at 6000 rpm engine speed. Furthermore, we visualized fuel behavior in the intake-port using a CCD camera synchronized with a stroboscope in order to compare with the analytical results. Boundary and intial conditions were employed by complete 1-D simulation of the engine using the WAVE code. Fuel was injected into the intake-port at two time intervals relative to the position of the intake valves so that the spray arrived when the valves were closed and fully open. The results showed that the trajectory of the spray was directed towards the lower wall of the port with injection against the closed valves. With open valve injection, a large portion of the fuel was lifted by the co-flowing air towards the upper half of the port and this was confirmed by simulation and visualization.

An Experimental Study on Convective Boiling of R-22 and R-410A in Horizontal Smooth and Micro-fin Tubes

  • Kim, Yongchan;Seo, Kook-Jeong;Lee, Kyu-Jung;Park, Youn cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제15권8호
    • /
    • pp.1156-1164
    • /
    • 2001
  • Evaporation heat transfer coefficients and pressure drops were measured for smooth and micro-fin tubes with R-22 and R-410A. Heat transfer measurements were performed for 3.0m long horizontal tubes with nominal outside diameters of 9.52 and 7.0mm over an evaporating temperature range of -15 to 5$\^{C}$, a mass flux range of 68 to 211kg/㎡s, and a heat flux range of 5 to 15kW/㎡. It was observed that the heat transfer coefficient increased with mass flux. Evaporation heat transfer coefficients of R-22 and R-410A increased as the evaporating temperature dropped at a lower heat flux. Generally, R-420A showed the higher heat transfer coefficients than R-22 in the range of low mass flux, high heat flux and high evaporating temperature. Pressure drop increased with a decrease of evaporating temperature and a rise of mass flux. Pressure drop of R-22 was higher than that of R-410A at the same mass flux.

  • PDF

수중 하베스트형 빙축열 시스템의 축방냉 특성 (Experiment of Characteristic on the Charge and Discharge of Cold for In-Water Harvest-Type Ice Storage System)

  • 장용식;최인수;문춘근;천석현;김재돌;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.268-273
    • /
    • 2001
  • A fundamental study on the harvest-type ice storage system applied ice making method in-water and its temperature characteristics in ice storage system was performed experimentally of the charge and discharge of cold. This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks.

  • PDF

투과전자현미경에 의한 HgCdTe/양극산화막/ZnS 계면 특성에 관한 연구 (TEM Study on the HgCdTe/Anodic oxide/ZnS Interfaces)

  • 정진원;김재묵;왕진석
    • 전자공학회논문지A
    • /
    • 제32A권9호
    • /
    • pp.121-127
    • /
    • 1995
  • We have analyzed the double insulating layer consisting of anodic oxide and ZnS through TEM experiments. The use of double insulating layer for HgCdTe surface passivation is one of the promising passivation method which has been recently studied deeply and the double insulating layer is formed by the evaporation of ZnS on the top of anodic oxide layer grown in H$_{2}$O$_{2}$ electrolyte. The structure of anodic oxide layer on HgCdTe is amorphous but the structure of oxide layer after the evaporation of ZnS has been changed to micro-crystalline. The interface layer of 150.angs. thickness has been found between ZnS and anodic oxide layer and is estimated to be ZnO layer. The results of analysis on the chemical components of ZnS, the interface layer and anodic oxide layer have showed that Zn has diffused into the anodic oxide layer deeply while Hg has been significantly decreased from HgCdTe bulk to the top of oxide layer. The formation of ZnO interface layer and the change of structure of anodic oxide layer after the evaporation of ZnS are estimated to be defects or to induce the defects which might possibly affect the increase of the positive fixed charges shown in C-V measurements of HgCdTe MIS.

  • PDF

열벽 증착(hot-wall evaporaton) 방법으로 성장한 ZnTe:Cu 박막의 전기적 특성 (Electrical Properties of ZnTe:Cu Films Grown by Hot-Wall Evaporation)

  • 박성래;남성윤;오병성;이기선
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.51-57
    • /
    • 1997
  • 열벽 증착(hot-wall evaporation)방법으로 Cu를 첨가한 ZnTe박막을 성장하였다. doping을 하지 않은 ZnTe박막의 전기 전도형은 p-형으로 전기 전도도는 $10^{-6}({\Omega}{\cdot}cm)^{-1}$을 정도로 매우 낮았다. 첨가한 Cu의 양에 따라 전기 전도도는 $10^2({\Omega}{\cdot}cm)^{-1}$까지 증가하였으나 이동도는 크게 변하재 않았다. Cu를 매우 많이 첨가한 경우는 금속과 같은 전기 전도도를 관찰하였다.

  • PDF