• Title/Summary/Keyword: EUT

Search Result 28, Processing Time 0.041 seconds

A Study on the Radiated Noise from Power Line during EFT Immunity Test (EFT(Electrical Fast Transient)내성 시험시 발생되는 전원선 복사 잡음에 관한 연구)

  • 정삼영;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.234-241
    • /
    • 2000
  • During the EFT immunity test, the fast transient voltage is injected to the power or signal line. The radiated noise from these lines influences the near-by EUT, and consequently, the reliability of the test result can be jeopardized. The measured data of the field strength and wave shape of the noise were compared with the result of the mathematical analysis using transmission line model. When the tests were performed by the conditions the same as stated in IEC 61000-4-4, the results showed that the magnitude of the radiated electric field strength was about 2.4KV/m, and it can cause severe interference to the intended operation of EUT.

  • PDF

Comparison of Correlation Algorithms between GTEM Cell and Semi-Anechoic Chamber (GTEM 셀과 전자파 반-무반사실 사이의 상관관계 알고리즘 비교.분석)

  • 권종화;이애경;최형도
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.188-195
    • /
    • 2002
  • This paper statistically verifies two correlation algorithms by comparing the data of GTEM cell to those of semi-anechoic chamber (SAC). Correlation algorithms considered in this paper are 3 and 15 position methods, which simulate the EMI test for an equipment under test (EUT) over the ground plane by using the radiated power from EUT located within GTEM cell. Also, the results obtained by two algorithms are compared with the theoretical values calculated from an ideal dipole model. From the results, it was found that the data obtained by two correlation algorithms and SAC have a strong correlation. In addition, the EMI data by 3 position method showed higher than those by 15 position method and SAC measurements.

Radiated Emission of Electrical Fast Transient/Burst Signal and Its Countermeasures (전기적으로 빠른 과도현상/버스트 신호의 복사방출과 대책)

  • Park, Soo Hoon;Kim, Dong Il;Park, Youn Joon;Nah, Seung Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.291-298
    • /
    • 2016
  • In this paper, we studied about the radiated emission of EFT(Electrical Fast Transient)/Burst signal, referenced IEC-61000-4-4 of the international EMC standard and its effect on EUT(Equipment Under the Test) when EFT/Burst signal (Conducted noise) induced on a power cable to EUT. Firstly, we set up test sample by the standard and +4 kV standard signal is induced by EFT/Burst signal generator with 1 m length power cable for 1 minute. Consequently, we found not only induced EFT/Burst signal along power line, but also directly radiated emission signal from EFT/Burst signal generator (Radiated emission noise of EFT/Burst). The radiated emission signal of EFT/Burst was 30 dB which is higher than limit of CISPR 22 which is international EMC standard. Moreover, we measured the electric field strength by changing distance from maximum radiated emission point to electric field strength tester. As a result, this electric field strength was 23 V/m which is higher than international EMC standard test level(CISPR 24). Therefore, it was confirmed that the probability of malfunction may be high when radiated emission of EFT/Burst noise exists near the EUT.

A Study on GSM Handset Structure for Radiation Power Optimization under Head Phantom (GSM 단말기에서 두부 팬텀 조건하의 방사 전력 최적화를 위한 단말기 구조에 관한 연구)

  • Yang, Bu-Young;Kim, Jung-Min;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.689-697
    • /
    • 2007
  • This thesis suggests ways on how to enhance handset radiation power under head phantom condition. Generally, peak EIRP(Effective Isotropic Radiated Power) is used to measure the radiation performance. TRP is more effective to represent indication of mobile radiation performance in the field than EIRP. In this case, we measure the TRP as an index of radiation power. The factors which effect TRP are antenna length, antenna position, folder angle and ground connection method. More detailed analysis is performed over these items. Significant item is ground connection method between main PCB and folder GND. Using the FPCB we connect main GND to folder GND through the hinge near the antenna. The result is that TRP attenuation is decreased about 5 dB under head phantom condition.

Design of a Bounded-wave EMP Simulator Antenna (Bounded-wave EMP Simulator 안테나의 설계)

  • Sun, Da-Young;Choi, Hak-Keun;Lim, Seong-Bin;Jang, Jae-Woong;Kim, Tae-Yoon;Choi, Geun-Kyung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.87-93
    • /
    • 2011
  • A threat of the EMP(Electromagnetic Pulse) is recently increasing, so the development of electromagnetic security technology against the EMP is needed. However, the state of the domestic electromagnetic security technology against the EMP is lower level than the foreign. In this paper, the bounded-wave EMP simulator antenna for the development of electromagnetic security technology against a threat of the EMP is designed. The structure of the designed antenna is from a sort of the basic form of the bounded-wave EMP simulator such as a parallel-plate simulator for testing EMP immunity performance within the EUT(Equipment Under Test). The design processes of the designed simulator is including wave launcher, transmission line and termination taper. In the working volume of the designed antenna, the test object within 30 cm is forming predominant TEM field, so it is confirmed that the designed EMP simulator antenna can be used as the EMP simulator.

Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation (IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석)

  • Seo, Chang-Su;Huh, Chang-Su;Lee, Sung-Woo;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.

Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber (전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안)

  • Kim, Kwang-Yong;Hong, Joo-Il;Han, Seung-Moon;Doo, Jin-Suk;Huh, Chang-Su;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.

  • PDF

A Study on Rotation Method Appling Slip-ring of Direction Finding Antenna Mast for Mobile Radio Wave Measurement System (이동형 전파측정시스템에서 슬립링을 적용한 방향탐지 안테나 마스트 회전 방법에 관한 연구)

  • Sohn, Ju-Hang;Han, In-Sung;Kim, Duck-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.499-504
    • /
    • 2017
  • A Mobile Radio Wave Measurement System (MRWMS)is a vehicle-mounted system designed to be operating in a single mission. The mission characteristic for mobile measurement requires mobility. For this, we must consider the arrangement and embedded method of MRWMS's antennas. In this paper, we described the measurement method design of direction detecting accuracy for MRWMS and designed the direction finding antenna mast capable of rotating itself by using a slip ring without turntable for Direction Finding (DF) accuracy test. As we removed the dependency of a limited local area by designing a measurement method of direction detecting accuracy, Equipment Under Test (EUT) zero-Adjustment and mounted process shortened. So, we the reduced production costs. We expect an improved cable loss value by shortening the RF cable length in accordance with our design. In addition, due to the same phenomenon, the entire system is lighter and the mobility is improved.

A Study on Design and Fabrication of Broad-Band EMC filter for PDP (PDP용 광대역 EMC 필터의 설계 및 제작에 관한 연구)

  • 김동일;구동우;양은정;김도연
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.437-443
    • /
    • 2003
  • A interference of outside electric source and electric fast transient(EFT) are origins of destroy and malfunction in the precise electrical and electronic equipments. It makes a serious obstacle as the form of conducted noise. Therefore, it is strongly needed to protect precision electrical and electronic equipments from the interference and EFT. In this research, a EMC filter composed of feed-through capacitors and ferrite beads of high permeability is designed and it's properties are investigated for PDP. The filter produced in this research have wide band frequency characteristics and more than 40 dB reflection loss in the frequence of 10 MHz∼1.5 GHz which satisfy the standard of CISPR Pub. 22 and the level 4 of IEC 61000-4-4.

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF