• Title/Summary/Keyword: ETS monitoring

Search Result 7, Processing Time 0.024 seconds

Methods for Measuring Exposure to Environmental Tobacco Smoke (ETS)

  • Wu, Joseph--M
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.19 no.2
    • /
    • pp.162-169
    • /
    • 1997
  • An important and somewhat under-emphasized issue in assessing the risk potentially associated with exposure to ETS is the reliability and objectivity of the methods used to measure the actual level of exposure. Objectivity of the science is crucial in this context since this topic tends to elicit strong social, emotional and political responses among the general public and the scientific community alike. This mini-review compares the strengths and limitations of various methods used in determining ETS exposure in scientific investigations. Methods reviewed include: questionnaire, area monitoring, bio-monitoring, and personal monitoring. In particular, results of several recent studies (conducted in the United States, Europe, and the Far East) using personal monitors in combination with questionnaire and bio-monitoring, which contribute to a more reliable, objective and realistic estimates of a person's actual exposure to 575, are discussed.

  • PDF

Performance Evaluation of Methodology for Personal Exposure Monitoring of ETS and VOCs in Non-occupational Environments (비작업장 환경에서의 ETS와 VOC에 대한 개인피폭량 측정 방법의 성능평가)

  • Baek Seong-Ok;Hwang Seung-Man;Mun Yeong-Hun;Kim Mi-Hyeon;Kim Seong-Ryeol;Choe Jin-Su
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.399-400
    • /
    • 1999
  • From the scientific point of view, any regulation of the emissions of toxic air pollutants in general, and ETS or VOCs in particular, will inevitably be based on exposure levels and consequential health effects, data of this nature is still lacking for most of ETS and VOCs. In this context, the importance of personal monitoring measurements of ETS and VOCs in relation to risk assessment has been emphasized previously.(omitted)

  • PDF

Differences in Environmental Tobacco Smoke Exposure between Self-reporting and Cotinine Test: The Application of Biomarkers (자가응답과 코티닌 측정에 의한 간접흡연 노출률 비교: 생체지표 활용의 정책적 필요성)

  • Park, Myung-Bae;Sim, Boram
    • Health Policy and Management
    • /
    • v.30 no.4
    • /
    • pp.505-512
    • /
    • 2020
  • Background: In monitoring exposure to environmental smoke (ETS), biomarkers can overcome the subjectivity and inaccuracy of self-reporting measurements, and have the advantage of reflecting ETS exposure in all places. This study aims to evaluate the effectiveness of ETS exposure measurement using biomarkers such as urine cotinine. Methods: This study used the Korea National Health and Nutrition Survey data from 2009 to 2018. A total of 28,574 non-smokers with urine cotinine data were selected for the study. The cotinine concentration and ETS exposure rate using urine cotinine was estimated and then compared with the self-reporting measurements. The degree of agreement among measurements of ETS exposure was confirmed. Results: As a result of measuring ETS exposure with urine cotinine, 23,594 (83.8%) out of 28,574 subjects were classified as to exposure groups. This estimate differs significantly from measurements made by self-reporting. In addition, the average concentration of cotinine in non-smokers has decreased to a 10th level over the past 10 years. Based on the biomarker, the sensitivity of the self-reporting was 8.5%-29.0%, the specificity was 16.4%-19.5%, and the kappa value was 2.0%-5.8%. Conclusion: The findings of our study show that self-reporting measurement does not well reflect the extent to which non-smoker's exposure to smoking materials. Whereas cotinine concentration has decreased significantly over the past 10 years, the ETS exposure rate has not reduced. It strongly suggests the need for intervention in the group of non-smokers exposed to low concentrations of smoke. Therefore, an assessment using biomarkers such as cotinine-based measurement should be made in the Health Plan 2030.

Vibration control of a time-varying modal-parameter footbridge: study of semi-active implementable strategies

  • Soria, Jose M.;Diaz, Ivan M.;Garcia-Palacios, Jaime H.
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.525-537
    • /
    • 2017
  • This paper explores different vibration control strategies for the cancellation of human-induced vibration on a structure with time-varying modal parameters. The main motivation of this study is a lively urban stress-ribbon footbridge (Pedro $G\acute{o}mez$ Bosque, Valladolid, Spain) that, after a whole-year monitoring, several natural frequencies within the band of interest (normal paring frequency range) have been tracked. The most perceptible vibration mode of the structure at approximately 1.8 Hz changes up to 20%. In order to find a solution for this real case, this paper takes the annual modal parameter estimates (approx. 14000 estimations) of this mode and designs three control strategies: a) a tuned mass damper (TMD) tuned to the most-repeated modal properties of the aforementioned mode, b) two semi-active TMD strategies, one with an on-off control law for the TMD damping, and other with frequency and damping tuned by updating the damper force. All strategies have been carefully compared considering two structure models: a) only the aforementioned mode and b) all the other tracked modes. The results have been compared considering human-induced vibrations and have helped the authors on making a decision of the most advisable strategy to be practically implemented.

Short-term follow up of thyroid function after pediatric hematopoietic stem cell transplantation (소아 조혈모세포이식 후 단기간 갑상선 기능의 변화)

  • Lee, Seon-Ju;Lee, Jae-Wook;Lee, Dae-Hyoung;Kwon, Young-Joo;Park, Young-Shil;Hwang, Hui Sung;Kim, Sun Young;Park, Ji Kyoung;Jang, Pil-Sang;Jung, Min-Ho;Chung, Nak-Gyun;Jeong, Dae-Chul;Cho, Bin;Kim, Hack-Ki;Lee, Byung-Churl
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1211-1215
    • /
    • 2006
  • Purpose : In this study, we analyzed the short term changes of thyroid function, incidence and risk factors of thyroid dysfunction soon after allogeneic hematopoietic stem cell transplantation (HSCT) in children. Methods : We enrolled 80 pediatric patients following allogeneic HSCT, at the Catholic HSCT center between January, 2004 and February, 2006. Serum TSH (thyroid stimulating hormone), total serum thyroxine and total serum triiodothyronine levels were systematically measured in 80 patients before the HSCT, and at 1 month, 6 months and 12 months after HSCT. Results : Thyroid function statistically decreased at 1 month after HSCT(P<0.001). Thyroid dysfunction at 1 month was observed in 43 (54 percent) of 80 patients, 31 (39 percent) of whom presented with euthyroid sick syndrome (ETS). Thyroid dysfunction was normalized within 1 year after HSCT. In univariate analysis, malignant disease and the presence of acute graft-versus-host disease (grade ${\geq}II$) were risk factors for ETS (P=0.04, 0.01 respectively). In multivariate analysis, we could not detect an independent risk factor for ETS (P=0.19, 0.06 respectively). Conclusion : The present study suggests that the incidence of thyroid dysfunction is high after allogeneic HSCT. Therefore, regular monitoring of thyroid hormone levels after HSCT is required.

The status of assisted reproductive technology in Korea in 2012

  • Committee for Assisted Reproductive Technology Statistics, Korean Society for Assisted Reproduction;Lee, Gyoung Hoon;Song, Hyun Jin;Choi, Young Min;Han, Hyuck Dong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.1
    • /
    • pp.47-51
    • /
    • 2017
  • Objective: This study was designed to report the status of assisted reproductive technology (ART) therapy in South Korea between January 1, 2012 and December 31, 2012. Methods: A localized online survey, originally developed by the International Committee Monitoring Assisted Reproductive Technologies, was first launched and provided to all available ART centers via email in 2015. Fresh embryo transfer (FET) cases were categorized as standard in vitro fertilization, intracytoplasmic sperm injection (ICSI), or half-ICSI. Thawed embryo transfer (TET) and other related procedures, including surgical sperm retrieval, were surveyed. Results: Data from 33,956 ovum pick-up procedures were provided by 75 clinics in 2012. Of the 33,088 cycles in which ovums were retrieved, a complete transfer was performed in 90.5% (29,932 cycles). In addition, 10,079 FET cycles were confirmed to have resulted in clinical pregnancy, representing a pregnancy rate of 30.5% per ovum pick-up and 33.7% per ET. The most common number of embryos transferred in FET was 2 (41.6%), followed by 3 (34.0%), and non-elective single ETs (10.0%). Of the 10,404 TET cycles in which transfer was completed, 3,760 clinical pregnancies (36.1%) were confirmed by ultrasonography. Conclusion: The overall clinical pregnancy rate for FET and TET cycles in 2012 was higher than in 2011 (33.7% vs. 33.2% and 36.1% vs. 31.1%, respectively). The most common number of embryos transferred in FET cycles was 2, unlike in 2011.