• Title/Summary/Keyword: ESP

Search Result 466, Processing Time 0.025 seconds

A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity (PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구)

  • Haneol Lee;Gwangtaek Lee;So-Hee An;Ye Won Park;Gunhee Lee;Kee Jung Hong;Inyong Park;Sang Bok Kim;Daehoon Park;Yeawan Lee;Dong-Keun Song;Yong-Jin Kim;Bangwoo Han;Hak-Joon Kim
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.

Development of the equipment for detecting the poor power facilities by receiving electric noises (전자파 잡음을 이용한 전기설비 불량 검출장치 개발)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

Collection Efficiency of Particles with Effect of Blocks in the Two-Stage Electrostatic Precipitator (2단식 전기집진기 내에서 블록의 영향에 따른 입자의 집진효율)

  • 박성호;박청연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.217-218
    • /
    • 2000
  • 유해입자 배출 저감을 위한 대기오염 제어장치로는 필터(filter), 관성장치(inertialdevices), 침전조(settling), 스크루버(scrubber), 전기집진기(ElectroStatic Precipitator, ESP)등이 있다. 이 중, 정전기력을 이용한 전기집진기는 대전과정과 집진과정이 동일한 곳에서 이루어지는 1단식(one-stage)과 독립적으로 이루어지는 2단식(two-stage)으로 분류되며, 2단식의 경우, 대전부(charging section)와 집진부(collecting section)는 몇 개의 대전셀(charging cell)과 집진셀(collecting cell)들로 구성되어져 있다. (중략)

  • PDF

멀티캐스트 적용을 위한 인터넷 키관리 프로토콜 SKIP 분석

  • 박응기
    • Review of KIISC
    • /
    • v.9 no.4
    • /
    • pp.25-40
    • /
    • 1999
  • 안전한 멀티캐스트 통신을 위하여 인증과 프라이버시 기능을 네트워크 계층에 두는 것이 효율적인 경우가 있다. IPv4나 IPv6과 같은 네트워크 계층 프로토콜에서 공통으로 사 용되는 대부분의 방식은 비세션 프로토콜(session-less datagram, oriented protocol)이다. 인 터넷 보안구조에서 정의하고 있는 키 관리 프로토콜인 SKIP은 IPv4와 IPv6에 적합하도록 정의된 IP 보안 프로토콜인 AH(authentication header)와 ESP(encapsulating security payload)에서 동작되도록 설계되어 있으며 IPv4나 IPv6과 같은 비세션 프로토콜에 연결되어 사용되도록 정의된 키 관리 기법이다. 본논문에서는 SKIP에 대하여 분석하며 멀티캐스트 환경에 적용하기 위한 고려사항을 검토하고 정리한다.

  • PDF

DEVELOPMENT OF AN ACTIVE FRONT STEERING SYSTEM

  • Kim, S.J.;Kwak, B.H.;Chung, S.J.;Kim, J.G.
    • International Journal of Automotive Technology
    • /
    • v.7 no.3
    • /
    • pp.315-320
    • /
    • 2006
  • We have developed an active front steering system(AFS) with a planetary gear train, which can vary the steering gear ratio according to the vehicle speed and improve vehicle stability by superimposing steering angle. We conducted vehicle tests showing that co-operated control of AFS with ESP can improve vehicle stability by direct control of tire slip angle and that steering reaction torque during AFS intervention can be compensated by torque compensation using electric power steering.

The Implementation of the Cryptographic Processor for IPSec (IPSec을 위한 암호 프로세서의 구현)

  • 황재진;최명렬
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.406-408
    • /
    • 2004
  • 인터넷 보안에 대한 중요성이 나날이 증가하고 있으며. 이러한 인터넷 보안 문제의 해결책으로 개발된 IPSec은 IP 계층에서 보안서비스를 제공하기 위하여 AH와 ESP를 사용하여 보안연계(Security Association) 서비스를 제공한다. 본 논문에서는 32-bit 데이터 베이스를 이용하여 새로운 AES로 채택된 Rijndael 암호 알고리즘과 HMAC-SHA-1 인증 알고리즘을 통합시킨 IPSec 암호 프로세서를 구현하였다. Xilinx ISE 5.2i를 사용하여 VHDL로 설계하였고, ModelSim으로 시뮬레이션 검증을 수행하였으며, Xilinx사의 Vertex XCV1000E로 구현하였다. 본 논문에서 구현한 IPSec 암호 프로세서는 WLAN이나 VPN, Firewall등에 응용될 수 있을 것이다.

  • PDF

Torsional effects in symmetrical steel buckling restrained braced frames: evaluation of seismic design provisions

  • Roy, Jonathan;Tremblay, Robert;Leger, Pierre
    • Earthquakes and Structures
    • /
    • v.8 no.2
    • /
    • pp.423-442
    • /
    • 2015
  • The effects of accidental eccentricity on the seismic response of four-storey steel buildings laterally stabilized by buckling restrained braced frames are studied. The structures have a square, symmetrical footprint, without inherent eccentricity between the center of lateral resistance (CR) and the center of mass (CM). The position of the bracing bents in the buildings was varied to obtain three different levels of torsional sensitivity: low, intermediate and high. The structures were designed in accordance with the seismic design provisions of the 2010 National Building Code of Canada (NBCC). Three different analysis methods were used to account for accidental eccentricity in design: (1) Equivalent Static Procedure with static in-plane torsional moments assuming a mass eccentricity of 10% of the building dimension (ESP); (2) Response Spectrum Analysis with static torsional moments based on 10% of the building dimension (RSA-10); and (3) Response Spectrum Analysis with the CM being displaced by 5% of the building dimension (RSA-5). Time history analyses were performed under a set of eleven two-component historical records. The analyses showed that the ESP and RSA-10 methods can give appropriate results for all three levels of torsional sensitivity. When using the RSA-5 method, adequate performance was also achieved for the low and intermediate torsional sensitivity cases, but the method led to excessive displacements (5-10% storey drifts), near collapse state, for the highly torsionally sensitive structures. These results support the current provisions of NBCC 2010.

Performance Analysis of a Satellite Communication System based on IPsec VPN (IPsec VPN 기반 위성 통신 시스템 성능 분석)

  • Jeong, Won-Ho;Hwang, Lan-Mi;Kim, Ki-Hong;Park, Sang-Hyun;Yang, Sang-Woon;Lim, Jeong-Seok;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Satellite signal is excellent broadband, can provide the same information in a wide range, but there is a disadvantage that much less of the security level of the data. Therefore, supplementation of safety is a serious problem than anything in the satellite communication. In this paper, it was simulated by applying ARIA in encryption technique and by applying transport mode, tunnel mode in security header AH and ESP in order to examine the effect of IPsec VPN. In addition, we had compare with general services that do not apply encryption in order to analyze the impact of the encryption algorithm. Channel, by applying the Markov channel and adding AWGN, is constituted a satellite communication environment. In case of retransmission based error control scheme, we applied Type-II HARQ scheme and Type-III HARQ scheme which are performance is a good way in recently, and it is constituted by a turbo code and BPSK modulation scheme. we were analyzed performance in BER and Throughput in order to compare the simulation more effectively.

Study on Improving Vulhearability in IPv4/IPv6 Header Translation Mechanism (IPv4/IPv6 헤더변환 방식에서의 취약성 개선에 관한 연구)

  • 황호준;유승재;김귀남
    • Convergence Security Journal
    • /
    • v.3 no.1
    • /
    • pp.73-84
    • /
    • 2003
  • The IPv4 that used to be generally used as a medium of computer communications in 1980s has reached its limits now. IPv6 (IP Version 6) is being prepared to solve the limitations of the IPv4. However, the biggest problem of IPv6 is that it is not compatible with the IPv4. To resolve the compatibility issue, Dual Stack, Tunneling and Header Converting methods have been proposed. The Header Converting method allows communications between the IPv4 and IPv6 networks with the converter. This method's strength is that it is easy to embody and the procedures for embodiment is simple. However, this method still contains the weaknesses that the existing IPv4 has. On the current document, the Header Converting method among the three methods is discussed to resolve the problems this method has. To solve the Header Converting method's weakness, the security problem between sections, the IP Header field values are converted to the relative field values and IPSec (IP Security) and ESP (Encapsulation Security Payload) are applied. The proposed "Encrypted Header Converting Method" that is encrypted in packet units has solved the weakness that the pre-existing Header Converting method used to have.d to have.

  • PDF

psXML: A New XML-based Standard Protocol for Service-oriented, Open Architecture of Consumer Portal (psXML: 서비스 중심적 개방형 아키텍처를 가지는 수용가포털을 위한 XML 기반의 표준화)

  • Hong, Jun-Hee;Choi, Jung-In;Kim, Jin-Ho;Kim, Chang-Sub;Son, Sun-Young;Choi, Jun-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.108-117
    • /
    • 2007
  • RConsumer Portal is defined as "a combination of hardware and software that enables two-way communication between energy service providers(ESP, like KEPCO) and equipment within the consumer's premises". The portal provides both a physical link(between wires, radio waves, and other media) and a logical link(translating among language-like codes and etiquette-like protocols) between in-building and wide-area access networks. Thus, the consumer portal is an important, open public shared infrastructure in the future vision of energy services. This paper presents an XML based standard specification of service-oriented, open protocol for consumer portal system architecture. In the framework level, the XML protocol provides a useful bridge between services and platforms. The proposed standard protocol has been implemented into our developing consumer portal pilot system. The results imply the potential of global standards for consumer portal system by its minimum overhead in network and processor. The reposed XML is designated psXML in this paper.