• 제목/요약/키워드: ESDD

검색결과 52건 처리시간 0.025초

기후인자와 ESDD간의 상관관계 분석통한 오손도 예측 (The prediction of contamination degree through the relationship analysis between the climatic factor and ESDD)

  • 이원영;김도영;박흥석;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.440-443
    • /
    • 2003
  • Recently, with the rapid growth of industry, environmental condition became worse. With the mix of the various contaminants, such as, salts, dust and industrial pollutants, synergy effect could be happened. So, many researches have been focused on the issue. The cause of natural accident could be classified as, lightning, rainstorm and contamination. However, the accident by contamination influences on the larger area than that by lightning, and, in the case of rapid contamination, it takes a shorter time than rainstorm. The salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. So, in this investigation we make a research on the prediction of contamination degree through the relationship analysis between the climatic factor and ESDD.

  • PDF

지리적 영향에 따른 염해 오손물질의 분포에 관한 연구 (The Distribution of Salt Contamination with the Influence of Geographical Condition)

  • 장태인;양병모;강연욱;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1782-1784
    • /
    • 2000
  • This paper present the result of the investigation, the distribution of salt contamination with the influence of. geographical condition. To get the ESDD data, a conventional brush washing method was adapted, and IC(ion chromatography) was used to measure the quantity of anions, such as $Cl^-$ and ${SO_{4}}^{2-}$. And we make an analysis on the distribution of salt contamination with the increase of distance from shore. With 10 month ESDD data, we seek the 95% ESDD value with interpolation method. With these analyses, we had obtained the formulation concerned with the distance from sea. And could know the composition of contamination.

  • PDF

배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석 (Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

해안도달 거리에 따른 서해안 지역 염해 오손물의 분포특성 (The Distribution Characteristics of Salt Contaminants in West Coast Region with the Distance from Sea)

  • 최남호;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.276-280
    • /
    • 2001
  • This paper presents the result of a study on the distribution characteristics of salt contaminants in the west coast region, from Inchon to Yearsoo, of South Korea. To evaluate the distribution characteristics of salt contaminants, we had measured the equivalent salt deposit density(ESDD) with brush wiping method for thirteen month(from May 1999 to June 2000). Under the consideration on the measuring interval and method, normalization method was applied for the ESDD data. Besides the measurement, the chemical analysis (chromatography) was carried to investigate the relationship, between the electrical property and the amount of specific ingredient, such as sodium, magnesium and chloride. From the result, we could get the representative value of contamination for each site and distribution characteristics of salt contaminants with the distance from sea in the west coast.

  • PDF

불용성 오손물에 의한 절연물의 전기적 특성에 관한 연구 (The Electric Properties of Insulators Due to Non-soluble Contaminant)

  • 최남호;국연호;조성인;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.691-695
    • /
    • 2000
  • This paper present the result of the investigation, the electric properties of insulators due to non-soluble contamination. In general, the humidity and the amount of soluble salts such as NaCl, MgCl$_2$are the most dominant factor. Though the non-soluble do not distribute on conductivity of contaminant layer, that has the hygroscopic property. For this study, we make a mini-fog chamber with transparent acryl and the kaoline was used for non-soluble contaminant. The kaoline was applied with sprayer to get the specific ESDD and NSDD value, then the specimen was dried and installed horizontally. And to measure the leakage current a DAS system was developed with LabView. With the result, we could know the influence of non-soluble content and the relationship between NSDD and ESDD.

  • PDF

풍향 및 풍속이 배전설비의 염분오손에 미치는 영향 (The Effect of the Wind Direction and Velocity on the Salt Contamination of the Distribution Facilities)

  • 김찬영;김동명;권태호;천성남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.499-500
    • /
    • 2006
  • The salt contamination on the distribution facilities was investigated with the wind direction and velocity. Most previous researches were concentrated on the measurement of The Equivalent Salt Deposit Density(ESDD) without environmental consideration. The wind direction and velocity of the many environmental conditions are the most important factors to analyze salt contamination. Pohang area which is located on the south and east of the Korean Peninsula was chosen to do this research. This research will present the result of ESDD depending on the wind direction and velocity.

  • PDF

오손등급에 따른 배전기자재의 절연특성 연구 (Insulating Characteristics of the Distribution Facilities due to Grade of Salt Contamination)

  • 권태호;김동명;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1490-1491
    • /
    • 2007
  • The salt contamination on the distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, is one of the major coastal areas because more than 90% of salt contaminated failure occurs in distribution facilities. Did to stain distribution facilities artificially according to Equivalent Salt Deposit Density(ESDD) grade. The electrical test were performed on the non-polluted and polluted facilities(ESDD B, C, D grade).

  • PDF

옥외 절연물의 전기적 특성 평가를 위한 오손주기시험법 (A Pollution Cycle Method to Evaluate the Electrical Properties of Outdoor Insulators)

  • 이원영;최남호;한상옥;박강식;최태식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.6-9
    • /
    • 2001
  • In this research, a experiment was performed to evaluate the electrical properties of outdoor insulator with the pollution cycle method. Cycle test methods such as DCM of STRI, IEC 61109 compared with pollution cycle method. Using dimatic properties of Korea peninsula, we could get the optimal condition for the pollution cycle method. As the factor, clean and saline fog, voltage, rainfall and drying was chosen. The applied voltage is 13,2 kV, the salinity of salt solution was changed from 0.1 wt% to 1.5 wt% and one cycle is about 4 hours. To ensure the reproducibility and reliability, experiments repeated 4 times. The leakage current was measured with Lab VIEW and the ESDD was measured with brushwiping method. This experiment could ensure superiority of pollution cycle method which developed through the result of this experiment and we could know the relationship between ESDD, leakage current and relative humidity.

  • PDF

RTV 실리콘 고무의 내오손 특성에 관한 연구 (A Study on Anti-Pollutions Characteristics of RTV Silicone Rubber)

  • 허창수;이상엽;연복희;황명근;이종한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1651-1653
    • /
    • 1999
  • Room Temperature Vulcanizing (RTV) Silicone Rubber has been widely used to coat porcelain insulator to prevent formation water filming on insulator surface. and RTV silicone rubber has water repellency to suppress leakage current and consequent flashover. RTV silicone rubber's surface has been degradated by outdoor condition such as dust, salt, and water. etc. ESDD(Equivalent Salt Deposit Density) and leakage currents are increased by polymer surface toughness and degradation. In this paper, we investigated relations of surface toughness, ESDD, and leakage currents.

  • PDF

옥외 절연물의 오손도 예측 기법 및 프로그램 개발 (Development of an Expert Technique and Program to Predict the Pollution of Outdoor Insulators)

  • 김재훈;김주한;한상옥
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.28-34
    • /
    • 2007
  • Recently, with the rapid growth of industry, environmental condition became worse. In addition to outdoor insulators in seashore are polluted due to salty wind. Also this pollution causes the flashover and failure of electric equipments. Especially the salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. As well known, the pollution has a close relation with meteorological factors such as wind velocity, wind direction, temperature, relative humidity, precipitation and so on. In this paper we have statistically analyzed the correlation between the pollution and the meteorological factors. The multiple regression analysis was used for the statistical analysis; daily measured equivalent salt deposit density(dependent variable) and the weather condition data(independent variable) were used. Also we have developed an expert program to predict the pollution deposit. A new prediction system using this program called SPPP(salt pollution prediction program) has been used to model accurately the relationship between ESDD with the meteorological factors.