• Title/Summary/Keyword: ESCO Program

Search Result 4, Processing Time 0.017 seconds

Feasibility Analysis for Introducing ESCO Program of LED Luminaire Replacements in Schools

  • Shin, Hyunman;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Public institutions should replace their luminaires with LED lighting by 2020 to save energy. Because the LED lighting installation rate in schools has not yet reached the legal goal, the ESCO program feasibility was investigated. The amount of electricity used, electric rates, times of use in classrooms and fluorescent lighting maintenance costs etc., as well as the elements of lighting maintenance were analyzed. In the case of schools, the lamp usage time was so short that the ESCO projects with only energy savings were impossible. In order to execute the ESCO projects, the maintenance cost savings by replacing an existing luminaire should be considered and the introduction of the relatively cheaper tube type LED lamp than the flat type LED luminaire was required.

The Development of Mechanical Damper Using the Friction Pendulum Principle (마찰 진자 원리를 적용한 기계식 댐퍼의 개발에 관한 연구)

  • Lee, You-In;Han, Woo-Jin;Ji, Yong-Soo;Baek, Jun-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.361-368
    • /
    • 2015
  • Recently, the earthquake has been increasing a lot, damage of electric power facility has been serious as well. Nowadays, the importance of pipe support system such as Hanger, Brace, Snubber connecting the main structure have been emphasized. These devices can prevent pipe from damage so that reduce the vibration and shock acting on the pipe. For this reason, the FCD(Friction Concave Damper) was developed and has been expected to reduce the vibration on the pipe through the Friction Pendulum System. This paper was described the introduction of self-developed mechanical damper using the friction pendulum principle and the characteristic test was performed to verify the performance of the device. Additionally the test results have been compared with predicted F.A.P(FCD Analysis Program-self developed) results. As a result, reliability of design could be improved.

Selection of Energy Conservation Measures for Building Energy Retrofit: a Comparison between Quasi-steady State and Dynamic Simulations in the Hands of Users

  • Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.5-12
    • /
    • 2016
  • Purpose: Quasi-steady state simulations have played a pivoting role to expand the user group of simulation to design engineers and architects in Korea. Initially they are introduced in the market as a building energy performance rating tool. In domestic practice, however, quasi-steady state simulations seem to be regarded as a de facto simulation only available for energy retrofit. Selection of ECMs and economic feasibility analysis are being decided through these tools, which implies that running these tools has become a norm step of the Investment-grade Audit. Method: This study aims at identifying issues and problems with the current practice via test cases, analyzing the reasons and opportunities, and then eventually suggesting proper uses of quasi-steady state and dynamic simulations. Result: The functionality of quasi-steady state simulations is more optimized to the rating. If they are to used for energy retrofits, their off-the-shelf functions also need to be expanded for customization and detailed reports. Yet their roles may be limited only to the go/no go decision; because their algorithms are still weak at precisely estimating energy and load savings that are required for making investment decisions compared to detailed simulations.

Study on Development of Subroutine based on TRNSYS for Unglazed Transpired Air Collector System (TRNSYS 기반 무창기공형 공기식 집열 시스템 부프로그램 개발에 관한 연구)

  • Park, J.U.;Lee, E.J.;Chung, M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2003
  • UTAC(unglazed transpired air collector) system has unique advantage for space heating and tempering ventilation air over the conventional collector system such as flat plate and vacuum collector. UTAC can improve radiative and convective loss due to nonglazed component and enhanced plate surface configuration. and heating energy and its equivalent green house emission performance can be improved from the use of this like collector in building application. The Option D Calibration simulation approach of IPMVP(International Performance Measurement and Verification Protocol) in ESCO businesses has been recommended to use of the calibrated computer modules like these Energy-10. DOE2.1E and TRNSYS(transient system simulation). This study is to develop subroutine type-203 of TRNSYS15.2 program and appraise thermal performance of UTAC. With newely addeded subroutine type-203. 1) Thermal performance of unglazed transpired collector could be possible based on dimensionless variables such as efficiency and heat exchanger effectiveness. and 2) Assessement of energy consists of solar useful and insulation saving for UTAC could be possible.