• 제목/요약/키워드: ER 밸브

검색결과 28건 처리시간 0.031초

유압제어시스템 적용을 위한 ER 밸브의 내구성 평가 (Durability Evaluation of ER Fluids in Hydraulic Control Systems)

  • 김도태;장성철
    • 한국공작기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

ER밸브를 이용한 자동 하역 시스템의 제어 (II) -하역시스템의 모델링 및 제어- (Control of Automatic Cargo Handling System Using ER Valves (II) -Modeling and Control of Cargo Handling System-)

  • 성금길;정달도;최승복
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.53-60
    • /
    • 2001
  • This paper presents a position control of a platform at the seaport cargo handling system. After brief description of the operating principles of the cargo handling system, the governing equation of the moving platform is derived. The equation is described in the state space model, and a robust H$_{\infty}$ controller to achieve position tracking of the moving platform. which can carry 200ton of containers, is formulated. In the synthesis of the controller, the weight of the container is treated as uncertain parameter. Both regulating and tracking control responses are analyzed for the loading and unloading procedures of the proposed automatic cargo handling system.

  • PDF

전기유동유체를 이용한 실린더형 밸브의 성능 고찰 (Performance Investigation of a Cylindrical Valve Featuring Electro-Rheological Fluids)

  • 김기선;정달도;이효정;최승복;정재천
    • 한국정밀공학회지
    • /
    • 제11권4호
    • /
    • pp.148-157
    • /
    • 1994
  • A multi-cylindrical hydraulic valve incorporating with an electro-rheological(ER) fluid is developed in this study. Field-dependent Bingham properties of the ER fluid are exploited to devise the valve system which features fast system response as well as simple mechanism. The fast response is accrued from almost instant response characteristics of the ER fluid itself, and the mechanism configuration is simplified since no nechanically moving parts are required. The material properties of the ER fluids to be utilized for modeling of the proposed valve system are firstly tested with a couette-type electroviscometer. The design and manufacturing processes are then undertaken on the basis of model parameters. The performance characteristics of the valve system are evaluated in terms of pressure variations with respect to the intensity of employed electric fields and flow rates.

  • PDF

ER-Valve 간극내에서 분산계 ER유체의 유동특성 (Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve)

  • 장성철;염만오;이종두;장성수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

ER 댐퍼의 밸브 형상에 따른 감쇠 특성의 해석 및 실험 (An Analysis and Test Results of Damping Characteristics of ER Dampers with Two Different Valve Types)

  • 장보영;이종민;김창호;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.608-613
    • /
    • 1998
  • Damping characteristics of ER dampers and flow rates inside ER valve with two different valve types were analyzed and compared with test results. Fluid flow inside ER valves was modeled by Bingham plastic model and Hagen-Poiseulli flow, while the equations of motion of total ER damper system were modeled by flow and hydraulic force balance. A general straight valve case was compared with a bended valve case which is newly tested for a possible improvement of ER damping force. As expected, the bended ER valve generates higher damping force and lower flow rates than the conventional straight ER valve due to additional flow restriction at the bended section. Analytical models of ER valve and ER damper generally predict reasonable performance characteristics of tested results. Therefore, developed analysis can be used for designing new ER dampers and simulation of ER semi-active suspension system as well.

  • PDF

평판형 ER-Valve의 제작 및 성능실험 (Design and Performance Test of Plate Type ER-Valve)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

신경제어기법을 이용한 ER 밸브 브리지-실린더 시스템의 위치제어 (Position control of an ER valve bridge-cylinder system via neural network)

  • 최우연;최승복;정재천
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1441-1444
    • /
    • 1996
  • This paper presents the position control of a double-rod cylinder system activated by an electrotheological(ER) valve unit. Following the composition of a silicone oil-based ER fluid, theological properties of the ER fluid are experimentally tested as a function of imposed electric fields to determine appropriate design parameters of the ER valve. The ER valves are then designed and manufactured. Subsequently, the pressure drop of the ER valve is evaluated with respect to the intensity of the electric field. Four ER valves bridge-cylinder system is formulated, and the governing equations for the system are derived. A neural network control scheme is then synthesized to perform the position control of the cylinder system. Tracking control responses are experimentally evaluated and presented in order to demonstrate the effectiveness of the proposed control system.

  • PDF

유압밸브 적용을 위한 ER 유체의 역학적 특성 고찰 (Investigation of Mechanical Characteristics of ER Fluids for Application in Hydraulic Valve)

  • 김옥삼;이현창;박우철
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.84-90
    • /
    • 2001
  • The electro-reheoligical(ER) effect refers to the abrupt change in viscosity in certain suspensions on application of an electric field. This paper presents experimental results on material properties of an ER fluids subjected to electrical fatigues. As a first step, two types of EF fluids are made of arabic gum and methyl cellulose(MC) choosing 25% of parti-cle weight-concentration. Following the construction of test mechanism for electrical durability of ER fluid, the dynamic yield shear stress and current density of the ER fluids are experimentally distilled as a function of electric field. The yield shear stress of operated ER fluids are distilled and compared with those of unused ER fluids.

  • PDF

ER 유체로 작동되는 벨브의 제작 및 성능실험 (Design and Performance Test of Valve Operated by ER Fluids)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.63-68
    • /
    • 2004
  • Recently ER fluids are put to practical use in fluid power industry field. As only with electrical signal change to the valve in which ER fluid flowing, ER fluid flow is controlled, so devepment of simple ER valves have been tried. In this case a technical problem is to check the pressure drop caused from flow rate change in valves because the pressure drop is very small. In this study ER valves are designed and manufactured, and small pressure drop induced from flow rate change is checked by pressure transducer which is made with appling strain gage. The ER valves and pressure drop check method are considered to be applied to the fluid power industry.

3포트 ER 밸브 개발을 위한 분산계 ER유체의 유동특성에 관한 연구 (A Study on Flow Characteristics of Dispersive ER Fluids for Development of 3-port ER Valves)

  • 장문제;장성철;염만오;이동극;김기홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.125-131
    • /
    • 2005
  • The purpose of the present study is to examine the flow characteristics of ER fluids between 2 port and 3 port rectangular tube brass electrodes. ER fluid is made silicon oil mixed with $2-3wt\%$ starch having hydrous particles. Flow visualization of the ER fluids were obtained by CCD camera measuring those of the clusters using an image processing technique. This research found the flow $rate(Q_L)$ with 0 kV /mm, 0.5kV/mm and 1.0kV/mm for $Q_L\;=\;0,\;0$ and $5.73cm^3/s$. When the strength of the electric field increased, the cluster of ER fluids are clearly strong along the rectangular tube and the flow rate(Q) decreased.

  • PDF