• Title/Summary/Keyword: EQS

Search Result 23, Processing Time 0.037 seconds

Seismic Responses of Seismically Isolated Nuclear Power Plant Structure Considering Post-Yield Stiffness of EQS Bearing (EQS 면진장치의 항복 후 강성을 고려한 면진 원전구조물의 지진응답)

  • Kim, Byeong-Su;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.319-329
    • /
    • 2016
  • The Eradi Quake System (EQS) is a seismic isolation bearing system designed to minimize forces and displacements experienced by structures subjected to ground motion. The EQS dissipates seismic energy through friction of Poly Tetra Fluoro Ethylene (PTFE) disk pad. In general, a force-displacement relationship of EQS has post yield stiffness hardening during large inelastic displacement. In this study, seismic responses of seismically isolated nuclear power plant (NPP) subjected to design basis earthquake (DBE) and beyond design basis earthquakes (150% DBE and 167% DBE) are compared considering the post yield stiffness hardening effect of EQS. From the results, it can be observed that if the post-yield stiffness hardening effect of EQS is increased, the displacement response of EQS is reduced, and the acceleration and shear responses of containment structures of NPP is increased.

A Study on the Application of EQS bearings for the Seismic Isolation of Building Structures by ICT Case study (ICT센터 사례 연구를 통한 EQS의 건축 구조물 면진에의 적용 연구)

  • Yu, Seong-Mun;Lee, You-In;Ji, Yong-Soo;Choi, Dae-Sung;Kim, Doo-Kie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.

Study on the Performance Improvement of an EQS Device Applied Nuclear Power Plant (원전 EQS 면진장치의 성능개선을 위한 연구)

  • Lee, You In;Lee, Yu Jin;Lee, Hong Pyo;Cho, Myung Sug;Jee, Young Su;Beak, Jun Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • This paper presents the performance improvement of an EQS (Eradic Quake System) device applied to a nuclear power plant. For the nuclear facility, the EQS device needs to be ensured to have high quality, flexibility of design and reliability. To improve the reliability of the design, the hysteresis of the device must be exactly predicted. The friction coefficient of PTFE (PolyTetraFluoroEthylene) and the stiffness of the MER-Spring are considered as the factors influencing the hysteresis curve. In this paper, those factors are analysed to predict the behavior of the device and to improve the equipment of the EQS device. The results of the improved EQS device have been verified via a tests to be comparable with the predicted results. The estimation results indicate that considering those factors is more appropriate than the results of the previous design and method.

Variation of Rail's Axial Compressive Force on Railway Bridges Due to Thermal and Seismic Loads with using EQS Bearings (EQS 면진받침 사용 시 온도하중 및 지진하중에 대한 철도교량 레일 압축력 변화)

  • Kim Lee Hyeon;Kim Haksoo;Choi Eunsoo
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.3
    • /
    • pp.276-285
    • /
    • 2005
  • This study discussed the effect on rail's axial force due to thermal and seismic loads according to supporting conditions of railway bridges; the considered supporting conditions are 1)simply supported, 2)roller at both ends, and 3)roller with horizontal spring at both ends. Closed form solutions are used to calculate the axial farces on rails. The roller at both ends of a bridge span decreases the compressive axial force on rail due to thermal load compared with the simply supported condition. However, the lateral springs at roller are not helpful to decrease the rail's compressive axial force.

Air Pollution Trends in Japan between 1970 and 2012 and Impact of Urban Air Pollution Countermeasures

  • Wakamatsu, Shinji;Morikawa, Tazuko;Ito, Akiyoshi
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.4
    • /
    • pp.177-190
    • /
    • 2013
  • Air pollution trends in Japan between 1970 and 2012 were analyzed, and the impact of air pollution countermeasures was evaluated. Concentrations of CO decreased from 1970 to 2012, and in 2012, the Japanese environmental quality standard (EQS) for CO was satisfied. Concentrations of $SO_2$ dropped markedly in the 1970s, owing to use of desulfurization technologies and low-sulfur heavy oil. Major reductions in the sulfur content of diesel fuel in the 1990s resulted in further decreases of $SO_2$ levels. In 2012, the EQS for $SO_2$ was satisfied at most air quality monitoring stations. Concentrations of $NO_2$ decreased from 1970 to 1985, but increased from 1985 to 1995. After 1995, $NO_2$ concentrations decreased, especially after 2006. In 2012, the EQS for $NO_2$ was satisfied at most air quality monitoring stations, except those alongside roads. The annual mean for the daily maximum concentrations of photochemical oxidants (OX) increased from 1980 to 2010, but after 2006, the $98^{th}$ percentile values of the OX concentrations decreased. In 2012, the EQS for OX was not satisfied at most air quality monitoring stations. Non-methane hydrocarbon (NMHC) concentrations generally decreased from 1976 to 2012. In 2011, NMHC concentrations near roads and in the general environment were nearly the same. The concentration of suspended particulate matter (SPM) generally decreased. In 2011, the EQS for SPM was satisfied at 69.2% of ambient air monitoring stations, and 72.9% of roadside air-monitoring stations. Impacts from mineral dust from continental Asia were especially pronounced in the western part of Japan in spring, and year-round variation was large. The concentration of $PM_{2.5}$ generally decreased, but the EQS for $PM_{2.5}$ is still not satisfied. The air pollution trends were closely synchronized with promulgation of regulations designed to limit pollutant emissions. Trans-boundary OX and $PM_{2.5}$ has become a big issue which contains global warming chemical species such as ozone and black carbon (so called SLCP: Short Lived Climate Pollutants). Cobeneficial reduction approach for these pollutants will be important to improve both in regional and global atmospheric environmental conditions.

Anti-Oxidative and Anti-Inflammatory Effects of Green Tea Mixture and Dietary Fiber on Liver of High Fat Diet-Induced Obese Rats (고지방 식이로 유도된 비만 흰쥐의 간에서 식이섬유와 녹차혼합물의 항산화 및 항염증 효과)

  • Kim, Jong-Dai;Lee, Byung-Il;Jeon, Yun-Hui;Bak, Jong-Phil;Jin, Hai-Lan;Lim, Beong-Ou
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • This study was conducted to investigate anti-oxidative and inflammatory inhibition effects of green tea and dietary fiber mixture on liver of high fat diet-induced obese rats. 21 male rats were divided into 3 dietary groups and control group (A), high fat diet-induced group (B), and high fat (HF) diet-induced + EQ diet-$S^{(R)}$ diet group (C). Immunoblotting and RT-PCR analysis revealed protein expression, and anti-oxidant analysis revealed MDA (malondialdehyde), GSH (glutathione), and free DPPH radical. As a results, Body weight and food consumption were not significantly different between groups. The levels of MDA and GSH were lower in HF + $EQS^{(R)}$ group than in HF group. Also, the $EQS^{(R)}$ demonstrated to be more effective than HF group for a DPPH radicals scavenging activities. In addition, protein and mRNA level of TNF-$\alpha$ in HF + $EQS^{(R)}$ group showed relatively more potent pro-inflammatory activity inhibition compared to HF group. These results suggest that green tea mixture (EQ diet-$S^{(R)}$) provide positive effects on anti-oxidative and inflammatory inhibition effects on obese animal model or obesity related diseases.

The Urban Parks and Rivers Contribute to the Citizen Satisfaction and Utilization in Uijeongbu City

  • Kim, Yoo-Ill
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5_2
    • /
    • pp.151-162
    • /
    • 2010
  • This research aimed at measuring Park and Green Satisfaction (PGS) using subjective indicators of 'surface, line and spot' green evaluated by citizens. Also frequency of visits to park and green measured using objective indicators (number of visits) to find the relationship with PGS. A conceptual model of PGS was developed to relate evaluation to satisfaction and finally to utilization of open spaces. A sample of 500 questionnaire survey was employed for Uijeongbu City in Korea. A Structual Equation Modeling (AMOS) techniques was used to test the hypothesized relationship among factors (construct). As a result, first, PGS was explained by three latent factors of 'urban park' (${\gamma}=0.54$), 'linear facilities' (${\gamma}=0.25$), and 'surface green' (${\gamma}=0.15$) respectively. These three exogenous construct was found very useful classification system for open spaces of cities. Second, PGS (${\gamma}=0.34$) was found as a mediating variable to utilization of open spaces and also PGS was closely related to citizens Environmental Quality Satisfaction (EQS), such concept as, 'livability' and 'aesthetic quality'. The more satisfied with park and green the more people use the space. The PGS was an important QOL indicator together with the subjective indicator of 'livability'. Third, jogging and walking trails and bike ways along the river corridor was the most important green facilities contribute to the PGS and EQS. The near the distance (within 500m) the more number of visit to river corridor (green way). The river corridor promote accessibility to nature and other parks.

Cracking in reinforced concrete flexural members - A reliability model

  • Rao, K. Balaji;Rao, T.V.S.R. Appa
    • Structural Engineering and Mechanics
    • /
    • v.7 no.3
    • /
    • pp.303-318
    • /
    • 1999
  • Cracking of reinforced concrete flexural members is a highly random phenomenon. In this paper reliability models are presented to determine the probabilities of failure of flexural members against the limit states of first crack and maximum crackwidth. The models proposed take into account the mechanism of cracking. Based on the reliability models discussed, Eqs. (8) and (9) useful in the reliability-based design of flexural members are presented.

PREDICTION OF TURBULENCE TRAILING-EDGE NOISE AT LOW MACH NUMBERS (저마하수 난류 끝단 소음 예측)

  • Chang K.W.;Koh S.R.;Seo J.H.;Moon Y.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.249-253
    • /
    • 2005
  • The turbulence noise generated from blunt trailing-edge is numerically predicted by using the hydrodynamic/acoustic splitting method at the Reynolds number based on thickness of flat plate, $Re_h=1000$, and the freestream Mach number $M_o=0.2$. The turbulent flow field is simulated by incompressible large-eddy simulation and the acoustic field is predicted efficiently with the linearized perturbed compressible equations (LPCE) recently proposed by the authors. The turbulent flow characteristics are validated with the results of the previous experimental study and direct numerical simulation. The acoustic properties predicted from LPCE are compared with the solutions of analytical formulations.

  • PDF

Analysis of Estimation Technique for Solid Sediments in Combined Sewer Systems (합류식 관거 내 고형물 퇴적량 산정기법 분석)

  • Lee, Jae-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.405-415
    • /
    • 2006
  • The deposition of sewer solids during dry weather in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. Sewer solid accumulations in drainage systems also create the 'first-flush' phenomena during wet weather runoff periods. In order to solve these problems, measurement of these loadings for a given sewer system for extended period is needed but this task is very difficult and extremely expensive. In this study, generalized procedures for estimating sewer sediment solid during dry weather in combined sewer systems developed by the U. S. Environmental Protection Agency were applied in a drainage system in Korea. As result, the appropriate equation can be selected and applied according to the available data. However, the estimated solid sediment shows considerable difference between methods which classified by model and estimation methods of variable. The estimated values using equations (1) $\sim$ (4) are greater than that of equations (5) $\sim$ (9) and intermediate models show greater values than elaborate or simplest models. The comparison between simulated and measured solid deposition is difficult due to the absent of measurement data, but this estimation method can be used usefully for the management of sewer solid with reduction of cost and effort if the measurement is carried out and the equation is adjusted according to the actual drainage systems in Korea.