• Title/Summary/Keyword: EPOC

Search Result 20, Processing Time 0.027 seconds

A Study of Acade Game Scenarios using EMOTIV EPOC (EMOTIV EPOC을 활용한 아케이드 게임 시나리오 연구)

  • Jung, Sang-Hyub;Kim, Hyo-Chan;Kim, Ki-Nam;Han, Seung-Wan;Song, Min-Sun;Lee, Kang-Hee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.01a
    • /
    • pp.309-311
    • /
    • 2015
  • 본 논문에서는 EMOTIV사의 뇌파 측정기 EPOC을 통한 뇌파의 측정과 이를 활용한 게임 시나리오를 제안한다. 이 방안은 다소 복잡하고 어려운 뇌파의 측정과 활용을 EMOTIV사에서 제공하는 응용 프로그램을 이용하여 쉽게 뇌파를 측정하고 이를 실시간으로 아케이드 게임 시나리오와 연동이 가능하게 한다. EPOC Control Panel을 통해 뇌파의 측정 및 훈련을 하고 윈도우상의 키보드 값에 대응 시켜 여러 가지 활용이 가능하다.

  • PDF

Estimating excess post-exercise oxygen consumption using multiple linear regression in healthy Korean adults: a pilot study

  • Jung, Won-Sang;Park, Hun-Young;Kim, Sung-Woo;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.35-41
    • /
    • 2021
  • [Purpose] This pilot study aimed to develop a regression model to estimate the excess post-exercise oxygen consumption (EPOC) of Korean adults using various easy-to-measure dependent variables. [Methods] The EPOC and dependent variables for its estimation (e.g., sex, age, height, weight, body mass index, fat-free mass [FFM], fat mass, % body fat, and heart rate_sum [HR_sum]) were measured in 75 healthy adults (31 males, 44 females). Statistical analysis was performed to develop an EPOC estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and HR_sum were important variables in the EPOC regression models of various exercise types. The explanatory power and standard errors of estimates (SEE) for EPOC of each exercise type were as follows: the continuous exercise (CEx) regression model was 86.3% (R2) and 85.9% (adjusted R2), and the mean SEE was 11.73 kcal, interval exercise (IEx) regression model was 83.1% (R2) and 82.6% (adjusted R2), while the mean SEE was 13.68 kcal, and the accumulation of short-duration exercise (AEx) regression models was 91.3% (R2) and 91.0% (adjusted R2), while the mean SEE was 27.71 kcal. There was no significant difference between the measured EPOC using a metabolic gas analyzer and the predicted EPOC for each exercise type. [Conclusion] This pilot study developed a regression model to estimate EPOC in healthy Korean adults. The regression model was as follows: CEx = -37.128 + 1.003 × (FFM) + 0.016 × (HR_sum), IEx = -49.265 + 1.442 × (FFM) + 0.013 × (HR_sum), and AEx = -100.942 + 2.209 × (FFM) + 0.020 × (HR_sum).

Comparison of excess post-exercise oxygen consumption of different exercises in normal weight obesity women

  • Jung, Won-Sang;Hwang, Hyejung;Kim, Jisu;Park, Hun-Young;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.23 no.2
    • /
    • pp.22-27
    • /
    • 2019
  • [Purpose] The purpose of this study was to compare the excess post-exercise oxygen consumption (EPOC) between different types of exercises in women with normal weight obesity (NWO). [Methods] Nine university students with NWO having body mass index <25 kg/m2 and body fat percentage >30% participated in the study. First, continuous exercise (CEx) on an ergometer for 30 minutes at 60% of maximal oxygen consumption (VO2max) and interval exercise (IEx) at 80% VO2max for 2 minutes were performed. This was followed by exercise performed at 40% VO2max for 1 minute and at 80% VO2max for 3 minutes, performed 6 times repeatedly for a total of 26 minutes. The accumulation of short duration exercise (AEx) was performed for 3-bouts of 10 minutes each at 60% VO2max. [Results] The major findings were as follows: energy consumption during the exercises showed no significant difference between CEx, IEx, and AEx; EPOC was higher in IEx and AEx as compared to CEx for all dependent variables (e.g. total oxygen consumption, total calorie, summation of heart rate, and EPOC duration); and the lipid profile showed no significant difference. [Conclusions] Our study confirmed that when homogenizing the energy expenditure for various exercises in NWO individuals, EPOC was higher in IEx and AEx than in CEx. Therefore, IEx and AEx can be considered as effective exercise methods for increasing energy expenditure in NWO females.

Effect of interval exercise versus continuous exercise on excess post-exercise oxygen consumption during energy-homogenized exercise on a cycle ergometer

  • Jung, Won-Sang;Hwang, Hyejung;Kim, Jisu;Park, Hun-Young;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.23 no.2
    • /
    • pp.45-50
    • /
    • 2019
  • [Purpose] The purpose of this study was to confirm that the difference in excess post-exercise oxygen consumption (EPOC) during exercise of the spending the same calories between the continuous and interval exercise. [Methods] Thirty-four healthy college students who did not regularly exercise volunteered to participate in our study. Continuous exercise was performed on an ergometer for 30 min at 60% of maximal oxygen consumption (VO2 max). Interval exercise was performed on a cycle ergometer at 80% VO2 max for 2 min initially, followed by 40% VO2 max for 1 min, and 80% VO2 max for 3 min. This was repeated six times for a total of 26 min. [Results] The major findings were as follows: (1) energy consumption during exercise was not significantly different between continuous exercise and interval exercise groups; (2) EPOC was higher in interval exercise than in continuous exercise for all dependent variables (i.e., total oxygen consumption, total calories, summation of heart rate); and (3) there were no significant differences in the lipid profile between continuous and interval groups. [Conclusions] Our study confirmed that after equalizing energy expenditure for continuous and interval exercise on a cycle ergometer in subjects in their twenties, interval exercise results in higher EPOC than continuous exercise. These data suggest that interval exercise may be more effective than continuous exercise in reducing body fat, for a given amount of energy expenditure.

The Effects of Different Types of Treatment on EPOC and Anti-Oxidant Systems after Horseback Riding Exercise (승마기구운동 후 서로 다른 회복처치가 초과산소섭취량 및 항산화력에 미치는 영향)

  • Kim, Cheol-Woo;Baek, Yeong-Ho;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.11
    • /
    • pp.1612-1618
    • /
    • 2011
  • The present study was undertaken to analyze the effects of different types of treatment on excess post exercise oxygen consumption (EPOC), flexibility, free radical and antioxidants in women using a horseback riding therapeutic device. Subjects were trained in regular horseback riding exercises for 12 weeks (3 times/wk). The effects of this exercise were examined by means of a single session of horseback riding that lasted for 30 min. 21 women were recruited from a public health center and divided into 3 groups (passive recovery group, passive+massage recovery group, and dynamic recovery group). 3 types of recovery patterns were determined after a single trial of horseback riding exercise. Their flexibility were determined pre-and post-training by Paired T test, and ANOVA were used to analyze the data. The results were as follows: Among the 3 groups, the dynamic recovery group showed the highest levels of EPOC compared to the other groups, and also showed higher levels of anti-oxidants, as did the passive+massage recovery group compared to the passive recovery group. Moreover, horseback riding exercise greatly increased flexibility in the women. In conclusion, regular horseback riding training is recommended to enhance the flexibility of women and dynamic recovery is recommended to enhance EPOC and anti-oxidants after a single bout of exercise. Further study is needed in this area.

Robot Control based on Steady-State Visual Evoked Potential using Arduino and Emotiv Epoc (아두이노와 Emotiv Epoc을 이용한 정상상태시각유발전위 (SSVEP) 기반의 로봇 제어)

  • Yu, Je-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.3
    • /
    • pp.254-259
    • /
    • 2015
  • In this paper, The wireless robot control system was proposed using Brain-computer interface(BCI) systems based on the steady-state visual evoked potential(SSVEP). Cross Power Spectral Density(CPSD) was used for analysis of electroencephalogram(EEG) and extraction of feature data. And Linear Discriminant Analysis(LDA) and Support Vector Machine(SVM) was used for patterns classification. We obtained the average classification rates of about 70% of each subject. Robot control was implemented using the results of classification of EEG and commanded using bluetooth communication for robot moving.

Effect of red-pepper ingestion on excess post-exercise oxygen consumption in young women (고춧가루 섭취가 운동후초과산소섭취량에 미치는 영향)

  • Hwang, Hyejung;Suh, Heajung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.14 no.2
    • /
    • pp.87-93
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the effect of red-pepper ingestion on excess post-exercise oxygen consumption in young women. METHODS. The six female college students involved in this experiment. The subjects participated in two trials, standard meal (650 kcal) and standard meal +10 g red-pepper with 200 ml water. After the subjects allowed to have rest for 60 min, exercised by resistance program for 40 minutes. RESULTS. The excess post-exercise oxygen consumption (EPOC) was not affected by the red-pepper ingestion. However, post-exercise fat oxidation and plasma free fatty acid levels were higher in red-pepper trial than in control trial. CONCLUSION. Therefore, red-pepper ingestion before resistance exercise might be improve body fat reduction.

Uses of cone-beam computed tomography in San José, Costa Rica

  • Barba, Lucia;Berrocal, Ana Luisa;Hidalgo, Alejandro
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.103-109
    • /
    • 2018
  • Purpose: To analyze cone-beam computed tomography (CBCT) use, indications, and exposure parameters in San $Jos{\acute{e}}$, Costa Rica. Materials and Methods: A cross-sectional study was performed. All CBCT examinations over a period of 6 months at 2 radiological centers in San $Jos{\acute{e}}$, Costa Rica were evaluated. The examinations were performed with Veraview EPOC X550 and Veraviewepocs 3D R100 equipment. The patients' age and sex, clinical indication for CBCT, region of interest (ROI), repeat examinations, specialty of the referring dentist, field-of-view (FOV), tube voltage (kV), tube current (mA), and radiation dose (${\mu}Gy$) were evaluated. Patients were classified by age as children (${\leq}12years$), adolescents(13-18 years), and adults(${\geq}19years$). Results: The mean age of the 526 patients was 49.4 years. The main indications were implant dentistry and dental trauma. The most frequent ROIs were posterior, while anterior ROIs were much less common. The highest percentage of repeat examinations was in children. Fifty-six percent of the referring dentists were specialists. The most commonly used FOV was small. The mean tube voltage and current were 79.8 kV and 7.4 mA for Veraview EPOC X550 and 89.9 kV and 6 mA for Veraviewepocs 3D R100, respectively. The mean doses for children, adolescents, and adults were $6.9{\mu}Gy$, $8.4{\mu}Gy$, and $7.8{\mu}Gy$, respectively. Conclusion: Although CBCT was most commonly used in adults for implant dentistry, most repeat examinations were in children, and the highest mean dose was in adolescents. Additional dose optimization efforts should be made by introducing low-dose protocols for children and adolescents.

A Study on RF/PON Transmission System for CableTV Network Upgrade (케이블TV 네트워크 고도화를 위한 RF/PON 전송시스템에 관한 연구)

  • Ahn, Byoung-Jun;Park, Sung-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.8
    • /
    • pp.510-517
    • /
    • 2014
  • Recently, Cable communications services are becoming the HDTV to 3DTV, UHDTV broadcasting and 100Mbps to 1Gbps Internet. however existing technologies are limited to provide high-quality broadband services in the HFC network. The network upgrade technologies have some problems that Up/Downsteam frequency extension, Cost of upgrading by using DOCSIS3.1, EPOC and Legacy STB compatibility, Cost of upgrading the network by RFoG, RF overlay PON. This paper propose the RF/PON based gigabit Transmission system in order to provide the 1Gbps internet without using frequency and the Multiscreen to IP devices. After the proposed RF/PON system was developed and implemented, this paper evaluate the performance of RF/PON system for simultaneously real-time braodcasting and 1Gbps internet, Multiscreen service, and so on.