• Title/Summary/Keyword: EPA method

Search Result 250, Processing Time 0.023 seconds

Treatment Characteristics of 1,4-Dioxane by Advanced Oxidation Process System (AOP에 의한 1,4-다이옥산의 처리 특성에 관한 연구)

  • Lee, Soo;Kang, Hak-Su;Choi, Jae-Hyuk
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.32-40
    • /
    • 2008
  • 1,4-Dioxane is an EPA priority pollutant often found in contaminated ground waters and industrial effluents. Conventional water treatment techniques are limited to decompose this compound effectively. Therefore, an advanced oxidation process system (AOP) was used for the degradation of 1,4-dioxane. This research investigates the effect of adding oxidants, such as ozone, air, and $H_2O_2$ during the UV irradiation of 1,4-dioxane solution. In order to analyze 1,4-dioxane, a modified 8270 method, which is an improved method of U.S EPA 8720, was used. Degradation efficiencies of 1,4-dioxane by only UV irradiation at various temperatures were not significant. However, The addition of oxidants and air bubbling in the UV irradiation system for 1,4-dioxane decomposition showed the higher 1,4-dioxane degradation rate. And, during AOP treatment the tendency of TOC changes was similar to that of 1,4-dioxane decomposition rate.

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Analytical Method of Polycyclic Aromatic Hydrocarbons (PAHs) in Petroleum Contaminated Soils - Focused on the 16 US EPA Priority PAHs (유류오염토양 중 다환방향족탄화수소류(PAHs) 분석방법 연구 - US EPA 16종 PAHs를 중심으로)

  • Kim, Ji Young;Kim, Dongho;Kim, Tae Seung;Han, Jin-Suk;Lee, Jai-Young;Noh, Hoe-Jung
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.20-30
    • /
    • 2012
  • In case of analyzing PAHs (EPA 16 compounds) in oil-contaminated soils, the lump of peaks may occur because of the aliphatic and polar compounds in oil. This phenomenon is due to the lower accuracy of the analysis. To solve this problem, evaluation of application of silicagel-alumina multi-layer fraction was performed using standard substances and oil-contaminated soils. As a result of application of silicagel-alumina multi-layer fraction cleanup method using standard substances, recovery rates of surrogate standards (5 compounds including Naphthalene-d8) were 83~100% and those of target standards were 75~129%. These were to meet the target values (60~130%) in this study. When used 4% water-silicagel column analyze PAHs in oil-contaminated soils, Some problems were generated for quantitative analysis of PAHs; concentration of PAHs was underestimated due to an upward baseline of internal standard (recovery rate: less than 60%) and overestimated by the lump of peaks which were not purified (the biggest recovery rate: more than 400%). On the other hand, in case of silicagel-alumina multi-layer fraction cleanup method, recovery rate of surrogate standards were 61~101.6%. Therefore this cleanup method was considered a valid method to improve accuracy of analysis of PAHs in oil-contaminated soils.

Nitrate Volatilization Associated with Fine Particles($PM_{2.5}$) Measurement (미세입자($PM_{2.5}$) 측정시 유발되는 질산염 휘발)

  • 강병욱;이학성
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.81-82
    • /
    • 2000
  • 미국 EPA에서 $PM_{2.5}$를 새로운 대기환경기준으로 설정함에 따라 $PM_{2.5}$를 측정하기 위한 새로운 Reference method가 설정되었다. 새로운 $PM_{2.5}$측정방법(Reference method)은 2.5$\mu\textrm{m}$ cut-diameter를 가진 cyclone을 통하여 16.7 L/min 유량으로 24시간동안 테프론 필터에 시료를 채집하는 것으로 규정하고 있다. 최근에 국내외에서 $PM_{2.5}$에 대한 활발한 연구가 수행되고 있으며 이들 연구의 대부분이 현재 미국 EPA의 $PM_{10}$ Reference method인 Dichotomous 샘플러를 이용하여 테프론 필터에 시료를 채취하고 있다 (중략)

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil (토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.246-253
    • /
    • 1994
  • The simultaneous analysis of 11 semi-volatile organic acid compound which are listed as priority pollutants by EPA, were performed by GC/MS-SIM(selected ion monitoring). Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as an extraction and concentration method for priority pollutants in soil. Accurecy and precision of the methods were measured by the calculation of mean recovery, mean relative standard deviation, and method detection limit. Finally, limitations and prospects were discussed.

  • PDF

Degummed crude canola oil, sire breed and gender effects on intramuscular long-chain omega-3 fatty acid properties of raw and cooked lamb meat

  • Flakemore, Aaron Ross;Malau-Aduli, Bunmi Sherifat;Nichols, Peter David;Malau-Aduli, Aduli Enoch Othniel
    • Journal of Animal Science and Technology
    • /
    • v.59 no.8
    • /
    • pp.17.1-17.13
    • /
    • 2017
  • Background: Omega-3 long-chain (${\geq}C_{20}$) polyunsaturated fatty acids (${\omega}3$ LC-PUFA) confer important attributes to health-conscious meat consumers due to the significant role they play in brain development, prevention of coronary heart disease, obesity and hypertension. In this study, the ${\omega}3$ LC-PUFA content of raw and cooked Longissimus thoracis et lumborum (LTL) muscle from genetically divergent Australian prime lambs supplemented with dietary degummed crude canola oil (DCCO) was evaluated. Methods: Samples of LTL muscle were sourced from 24 first cross ewe and wether lambs sired by Dorset, White Suffolk and Merino rams joined to Merino dams that were assigned to supplemental regimes of degummed crude canola oil (DCCO): a control diet at 0 mL/kg DM of DCCO (DCCOC); 25 mL/kg DM of DCCO (DCCOM) and 50 mL/kg DCCO (DCCOH). Lambs were individually housed and offered 1 kg/day/head for 42 days before being slaughtered. Samples for cooked analysis were prepared to a core temperature of $70^{\circ}C$ using conductive dry-heat. Results: Within raw meats: DCCOH supplemented lambs had significantly (P < 0.05) higher concentrations of eicosapentaenoic (EPA, $20:5{\omega}3$) and EPA + docosahexaenoic (DHA, $22:6{\omega}3$) acids than those supplemented with DCCOM or DCCOC; Dorset sired lambs contained significantly (P < 0.05) more EPA and EPA + DHA than other sire breeds; diet and sire breed interactions were significant (P < 0.05) in affecting EPA and EPA + DHA concentrations. In cooked meat, ${\omega}3$ LC-PUFA concentrations in DCCOM (32 mg/100 g), DCCOH (38 mg/100 g), Dorset (36 mg/100 g), White Suffolk (32 mg/100 g), ewes (32 mg/100 g) and wethers (33 mg/100 g), all exceeded the minimum content of 30 mg/100 g of edible cooked portion of EPA + DHA for Australian defined 'source' level ${\omega}3$ LC-PUFA classification. Conclusion: These results present that combinations of dietary degummed crude canola oil, sheep genetics and culinary preparation method can be used as effective management tools to deliver nutritionally improved ${\omega}3$ LC-PUFA lamb to meat consumers.

Chemical Composition and Leaching Characteristic of Coal Fly Ash (비산석탄회의 화학조성과 용출특성)

  • Rhee, Dong Seok;Kim, Jong Boo;Joo, Kwang Suk
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.394-399
    • /
    • 1998
  • This study was carried out to characterize the chemical composition and leaching properties of heavy metals in coal fly ash, which was generated from Korean electrical power utilities in several million tons per year. Comparion with respect to the leachability of heavy metals between the Korea standard leaching test (KSLT) and the American Environment Protection Agency (EPA) method 1311 (TCLP: Toxicity Chracteristic Leaching Procedure) was performed. The concentration of Ag, As, Ba, Cd, Cr, Cu, Pb, Se, Hg in the leacheate was determined by ICP-MS. The analytical result showed a significant difference of the leachability according to the characteristics of the leaching solution except Se, suggesting the necessity of improvement in the leaching test method that is currently implemented in Korea.

  • PDF

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Matrix effect on the Determination of Inorganic Priority Pollutants in Sludges (오니 시료중의 무기 Priority Pollutants의 분석 과정에 미치는 매질의 영향)

  • Lee, Huk-Hee;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.297-304
    • /
    • 1998
  • The three analysis methods, EPA method 3050, the method offered by Ministry of Environment in Korea, and modified method corrected in this laboratory, were studied to investigate the effect of matrix on the analysis of inorganic priority pollutants. 7 inorganic priority pollutants(Ni, Cr, Cu, Zn, Pb, Cd, Hg) were spiked to the plating, leather, paper, electric, and dye sludges. Mean recovery of the elements except Hg was 95.5% when the procedure of EPA method was applied. However, recovery by the two other extraction methods showed 11.1% and 27.7%, respectively. Digestions were done by MDS (microwave digestion system) and $HNO_3+HClO_4$ methods. To study organic and inorganic matrix effect, samples were made by adding triethanol amine as a organic matrix and $FeCl_3{\cdot}6H_2O$+$AlCl_3{\cdot}6H_2O$ as a inorganic matrix, respectively. The extracts were analyzed by AAS and HG-AAS. Mean recovery of the elements by the $HNO_3+HClO_4$ procedure, except Hg, gave better result than that of the MDS method. Mean recovery of elements was decreased when organic and inorganic matrices were added in the sludge samples. The procedure of MDS and $HNO_3+HClO_4$ digestion gave higher recoveries than that of direct analysis. In general, the results of the studies showed a significant matrix effect on the inorganic priority pollutants analysis in sludges.

  • PDF