• Title/Summary/Keyword: ENERGY EFFICIENCY

Search Result 11,076, Processing Time 0.038 seconds

Comparison Analysis of Building's Heating Energy Consumption in the Apartment Complex - Focused on Apartment in Daejeon - (공동주택 단지 내 동별 난방에너지소요량 비교 분석 - 대전지역 아파트단지를 중심으로 -)

  • Jang, Young-Hye;Kim, Jeong-Gook;Kim, Jonghun;Jeong, Hakgeun;Hong, Won-Hwa;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.37-42
    • /
    • 2015
  • Purpose: Apartment is a typical residential type in Korea. In the past, apartment types were very monotonous. But today, the types of complex are changed because personal needs have been diversified and personalized. In order to meet those needs, construction companies are constructing various types of apartments. The more apartment types are diverse, the more the energy problems are taken place. So, the purpose of this study is to solve the problem of energy gap in the same complex through improving the thermal transmittance of wall. Method: Heating energy consumption of Building Energy Efficiency Rating System and heating energy usage of apartment show a similar trend on the graph. In order to identify the best position of heating energy consumption difference reduction, we change the building's U-value of front, back, side walls. Result: In the A complex, maximum and minimum heating energy consumption building's shapes are flat. the best efficiency is side U-value change and the worst is front change. In the E complex, maximum heating energy consumption building's shape is tower and minimum building shape is flat. Consequently, the front and back wall performance change was little effect to reduce energy gap, while the change of side wall's U-value show the great reduction between building's energy consumptions.

Energy Requirement of Rhode Island Red Hens for Maintenance by Slaughter Technique

  • Jadhao, S.B.;Tiwari, C.M.;Chandramoni, Chandramoni;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.7
    • /
    • pp.1085-1089
    • /
    • 1999
  • Energy requirement of Rhode Island Red (RIR) hens was studied by comparative slaughter technique. Seventeen hens above 72 weeks of age were slaughtered in batches. Batch I consisted of 5 hens which were slaughtered initially. Batch II comprised of six hens, which were fed ad libitum broken rice (BR)-based diet for 18 days. Record of feed intake, number of eggs laid and egg weight during the period was kept. These hens were slaughtered and body energy content was determined. Egg energy was consisted as energy deposited. Batch III consisting of six hens which were fed varying quantity of diet for 15 days, were slaughtered similarly as hens of batch II. Regression equation (body weight to body energy) developed on batch I was applied to batch II and developed on batch II was applied to batch III hens, to find out initial body energy content of hens. Egg energy (EE) was calculated according to formula: EE (kcal) = -19.7 + 1.81 egg weight (g). Regressing metabolisable energy (ME) intake on energy balance (body energy change + egg energy), maintenance ME requirement of hens was found to be $119.8kcal/kg\;W^{0.75}/d$. Multiple regression of ME required for production on energy retained as protein and fat (body plus egg energy) indicated that RIR hens synthesize proteins with an efficiency of 85.5 and fat with an efficiency exceeding 100 percent on BR based diet.

Enhanced Light Harvesting from F$\ddot{o}$rst-type resonance Energy Transfer in the Quasi-Solid State Dye-Sensitized Solar Cells (F$\ddot{o}$rst energy transfer 를 적용한 준고체 DSSC 의 효율향상)

  • Cheon, Jong Hun;Lee, Jeong Gwan;Yang, Hyeon Seok;Kim, Jae Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.117.1-117.1
    • /
    • 2011
  • We have demonstrated Forst-type resonance energy transfer (FRET) in the quasi-solid type dye-sensitized solar cells between organic fluorescence materials as an energy donor doped in polymeric gel electrolyte and ruthenium complex as an energy acceptor on surface of $TiO_2$. The strong spectral overlap of emission/absorption of energy donor and acceptor is required to get high FRET efficiency. The judicious choice of energy donor allows the enhancement of light harvesting characters of energy acceptor in quasi-solid dye sensitized solar cells which increase the power conversion efficiency. The enhanced light harvesting effect by the judicious choice/design of the fluorescence materials and sensitizing dyes permits the enhancement of photovoltaic performance of DSSC.

  • PDF

The Hammer Energy Delivered to the Drilling Rod in the SPT 1 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 1)

  • 조성민;정종홍;김동수;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.469-476
    • /
    • 2001
  • The Ν-value in the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the doughnut hammer with the hydraulic lift system and the automatic trip hammer system were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA) . The rod energy ratio, ΕR$\_$r/ was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ΕR$\_$r/ also varies according to the energy instrumentation system and the analysis methods.

  • PDF

The Long-Term Effect of Energy R&D Investment Based on Causal Loop Diagramming Analysis (국가 에너지 R&D의 중장기 효과평가를 위한 인과지도 분석)

  • Oh, Youngmin
    • Korean System Dynamics Review
    • /
    • v.14 no.4
    • /
    • pp.91-112
    • /
    • 2013
  • This article aims at revealing the dynamic relationships between the energy R&D investment and economic growth in Korea. To achieve this goal, we reviewed the effects of energy R&D investments and tried to make the holistic interconnections for describing the feedback loops between energy R&D and economic system. Energy R&D investments develop the renewable energy, energy efficiency and $CO_2$ emission reductions technologies for accomplishing the national strategic targets. The rapid obsolescence of technologies makes the inefficiency and negative effects in governmental energy R&D investments.

  • PDF

The research in rationalization of the use of energy in electric power (에너지 이용 합리화를 위한 전기에너지 사용계획 수립에 관한 연구)

  • Kim, Man-Kook;Nam, Si-Bok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.392-399
    • /
    • 2009
  • This study investigates and analyzed electrical energy curtailment effect by each business department and by energy use efficiency elevation equipment because do an energy use plan that is enforced in each variety business that is developed in domestic by model. When plan the recent electrical energy use with this, I wish to contribute in energy use general planning establishment improvement that is aiming energy efficiency improvement newly by groping improvement plan moment deduce problem. Specially, search present condition and problem by electrical energy curtailment equipment application that probes mass and analyzed, and is applied in present our country according to analysis contents to the latest energy use plan that was enforced on energy use rationality narration but allowed purpose.

  • PDF

Effects of the Damping Ratios of Power Generators on Power Efficiency of an Ocean Renewable Energy Converter Utilizing Flow Induced Vibrations of Two Circular Cylinders (두 원형실린더의 유동유발진동 현상을 이용하는 해양신재생에너지 변환기의 발전 효율에 발전기의 감쇠비가 미치는 영향에 관한 연구)

  • Kim, Eun Soo;Park, Hongrae;Kim, Dong Hwi;Baek, Hyung-min;Bernitsas, Michael M.
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2020
  • Most countries in the world are trying to reduce the use of fossil fuels in the production of electricity and replace them with renewable energy technologies. In Korea, there are abundant ocean renewable energy sources that will play an important role in power generation in the future. This paper introduces a new tidal energy converter utilizing flow induced vibration (FIV), which can work efficiently, even in the currents slower than 1.0m/s. All tests were conducted at the Marine Renewable Energy Laboratory at the University of Michigan to examine the effects of the damping ratio of the electric generators on the power outputs and power efficiencies. In these tests, two identical circular cylinders were used, and passive turbulence controllers were applied to the surface of the cylinders to enhance the FIV. The experimental results showed that by using the two cylinders in the FIV, the power output and efficiency reached up to 31 W and 36%, respectively. In particular, the results showed that the power efficiency was higher at the relatively low flow speed (4

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea (창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가)

  • Lim, Hee Won;Kim, Dong Yun;Lee, Soo Man;An, Jung Hyuk;Yoon, Jong Ho;Shin, U Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

Improvement of Energy Efficiency of LEACH Protocol for Wireless Sensor Networks (무선센서 네트워크를 위한 LEACH 프로토콜의 에너지 효율 향상 방안)

  • Lee, Sang-Hoon;Suk, Jung-Bong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2B
    • /
    • pp.76-81
    • /
    • 2008
  • LEACH (Low Energy Adaptive Clustering Hierarchy) has been proposed as a routing protocol with a hierarchical structure, in order to achieve the energy efficiency that is of primary importance in the wireless sensor networks. A wireless sensor network adopting LEACH is composed of a few clusters, each of which consists of member nodes that sense the data, and head nodes that deliver the collected data from member nodes to a sink node that is connected to a backbone network. A head node in a cluster allocates TDMA slots to its member nodes without taking into account whether they have data to transmit or not, thus resulting in inefficiency of energy usage of head node that remains in active mode during the entire round time. This motivates us to propose a scheme to improve the energy efficiency of LEACH, by assigning TDMA slots only to those member nodes who have data to send. As a result, the head node can remain sleep during the period of no data transmission from member nodes, leading to the substantial energy saving. By using the ns-2 simulator, we evaluate the performance of the proposed scheme in comparison with the original LEACH. Experimental results validate our scheme, showing a better performance than original LEACH in terms of the number of outliving nodes and the quantity of energy consumption as time evolves.

Effective CPU overclocking scheme considering energy efficiency (에너지 효율을 고려한 효과적인 CPU 오버클럭킹 방법)

  • Lee, Jun-Hee;Kong, Joon-Ho;Suh, Tae-Weon;Chung, Sung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.12
    • /
    • pp.17-24
    • /
    • 2009
  • More recently, the Green Computing have become a important issue in all fields of industry. The energy efficiency cannot be over-emphasized. Microprocessor companies such as Intel Corporation design processors with taking both energy efficiency and performance into account. Nevertheless, general computer users typically utilize the CPU overclocking to enhance the application performance. The overclocking is traditionally considered as an evil in terms of the power consumption. In this paper, we present effective CPU overclocking schemes, which raise CPU frequency while keeping current CPU supply voltage for energy reduction and performance improvement. The proposed scheme gain both energy reduction and performance improvement. Evaluation results show that our proposed schemes reduce the processor execution time as much as 17% and total computer system energy as much as 5%, respectively. In addition, our effective CPU overclocking schemes reduce the Energy Delay Product (EDP) as much as 22%, on average.