• Title/Summary/Keyword: ENERGY EFFICIENCY

Search Result 11,032, Processing Time 0.037 seconds

An Experimental Study of a Water Type PV/Thermal Combined Collector Unit (액체식 PV/Thermal 복합모듈의 성능실험연구)

  • Lee, Hyun-Ju;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.105-111
    • /
    • 2007
  • Hybrid PV/Thermal systems consisting of photovoltaic module and thermal collector can produce the electricity and thermal energy. The solar radiation increases the temperature of PV modules, resulting in the decrease of their electrical efficiency. Accordingly hot air can be extracted from the space between the PV panel and roof, so the efficiency of the PV module increases. The extracted thermal energy can be used in several ways, increasing the total energy output of the system. This study describes a basic type of PV/T collector using water. In order to analyze the performance of the collector, the experiment was conducted. The result showed that the thermal efficiency was 17% average and the electrical efficiency of the PV module was about $10.2%{\sim}11.5%$, both depending on solar radiation, inlet water temperature and ambient temperature.

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

Energy Efficiency Optimization for multiuser OFDM-based Cognitive Heterogeneous networks

  • Ning, Bing;Zhang, Aihua;Hao, Wanming;Li, Jianjun;Yang, Shouyi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.6
    • /
    • pp.2873-2892
    • /
    • 2019
  • Reducing the interference to the licensed mobile users and obtaining the energy efficiency are key issues in cognitive heterogeneous networks. A corresponding rate loss constraint is proposed to be used for the sensing-based spectrum sharing (SBSS) model in cognitive heterogeneous networks in this paper. Resource allocation optimization strategy is designed for the maximum energy efficiency under the proposed interference constraint together with average transmission power constraint. An efficiency algorithm is studied to maximize energy efficiency due to the nonconvex optimal problem. Furthermore, the relationship between the proposed protection criterion and the conventional interference constraint strategy under imperfect sensing condition for the SBSS model is also investigated, and we found that the conventional interference threshold can be regarded as the upper bound of the maximum rate loss that the primary user could tolerate. Simulation results have shown the effectiveness of the proposed protection criterion overcome the conventional interference power constraint.

Efficiency at Energy Industry : A Comparison of Energy Consumption Efficiency among Asian Pacific Countries

  • Kim, Tae-Ho
    • International Journal of Quality Innovation
    • /
    • v.9 no.3
    • /
    • pp.113-121
    • /
    • 2008
  • This paper proposes a scheme to estimate the technical efficiency of energy consumption and production and shadow prices of $CO_2$ emission in country-level at Asia Pacific countries by Data Envelopment Analysis (DEA). The result of technical efficiency estimation shows that there exists an heterogeneity and a substantial opportunity for improvement in technical efficiency at energy consumption and production across countries, specially in the $CO_2$ emission, which implies that more pollutant are spread in air. Each country will have the different willingness to pay for the additional $CO_2$ emission right and this result enables us to predict the competition in international $CO_2$ emission right market.

Estimation of Rebate Level for Energy Efficiency Programs Using Optimization Technique (최적화 기법을 이용한 에너지 효율 프로그램의 지원금 수준 산정)

  • Park, Jong-Jin;So, Chol-Ho;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.369-374
    • /
    • 2008
  • This paper presents the evaluation procedures and the estimation method for the estimation of optimal rebate level for EE(Energy Efficiency) programs. The penetration amount of each appliance is estimated by applying price function to preferred diffusion model resulted from model compatibility test. To estimate the optimal rebate level, two objective functions which express the maximum energy saving and operation benefit are introduced and by multi-objective function which can simultaneously consider two objective functions the optimal rebate level of each appliance is estimated. And then, using the decided rebate level and each penetration amount, the priority order for reasonable investment of each high-efficiency appliance is estimated compared to the results of conventional method. Finally, using a benefit/cost analysis based on California standard practice manual, the economic analysis is implemented for the four perspectives such as participant, ratepayer impact measure, program administrator cost and total resource cost.

The Efficiency Prediction for Plate Type Steam Reformer with Shape Change of Combustion Chamber (평판형 STR의 연소공간 형상변화에 따른 성능 예측)

  • Kim, Hun-Ju;Lee, Ji-Hong;Lee, Myeong-Yong;Lee, Sang-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.286-294
    • /
    • 2010
  • According to the propagation of fuel cell system, the importance of that system efficiency is being magnified. Thus, the efficiency improvement of reformer which is the important part of fuel cell system will be required. In structural aspect, the reformer is classified into cylindrical and plate type. Plate type reformer features better maintenance and space efficiency compared with cylindrical type. In this study, we changed the shape of combustion chamber to improve the reforming efficiency. And then we performed the CFD simulation to predict the spacial distribution of temperature. Analysis cased contains with baffles, fins, baffles and fins, and without those. In case of only with-baffle, temperature distributions were uneven because the high temperature stream was concentrated near the baffle end. In case of with-fin, the temperature distributions were relatively even than other cases.

The Effect of Energy Efficiency Investment on Industry's Productivity Growth (에너지효율화 투자의 산업생산성 파급효과 분석)

  • Lee, Myunghun
    • Environmental and Resource Economics Review
    • /
    • v.20 no.2
    • /
    • pp.291-308
    • /
    • 2011
  • The success of a target of 'low-carbon green growth' depends on whether installing energy-saving capital would result in an increase in industry's productivity growth. Defining total factor productivity from a dual cost function, this paper estimates the contribution of energy efficiency investment to productivity growth by analyzing the sources of growth of productivity index for the primary metal industries. Empirical results show that, on average, energy efficiency investment increased the annual rate of productivity growth by 1.16 percentage points over th period 1982~2006. In addition, The scale effect positively affected the contribution of energy efficiency investment on productivity growth.

  • PDF

Energy Efficiency and CO2 Emissions of the Transportation System of Kazakhstan: A Case of Almaty

  • Yessekina, Aiman;Urpekova, Amina
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.2 no.3
    • /
    • pp.41-46
    • /
    • 2015
  • Energy saving in the transport sector in the framework of the annual growth of energy consumption, the degree of negative impact on the environment and the amount of harmful emissions are becoming increasingly important. The article considers the world tendencies of energy consumption in transportation sector and emphasizes its dependency from oil. Also article describes the dynamics of energy use and CO2 emissions from transport of city Almaty. In conclusion authors identify a number of problems in the transport sector, which hinder the implementation of energy efficiency measures and measures to reduce CO2 emissions.

EFFECT OF DIFFERENT DIETARY PROTEIN AND ENERGY LEVELS ON THE PERFORMANCES OF STARCROSS PULLETS

  • Uddin, M. Salah;Tareque, A.M.M.;Howlider, M.A.R.;Khan, M. Jasimuddin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.4
    • /
    • pp.361-368
    • /
    • 1991
  • In two experiments 640 starcross replacement pullets between 25 and 154 days of age were fed ad libitum on either of 16 diets formed by the combination of $4CP{\times}4ME$ levels to study the interaction of CP and ME on growth performances. In both experiments, feed intake decreased, but protein intake, energy intake, live weight gain and feed conversion efficiency increased and sexual maturity hastened with the increase of dietary protein and/or energy level. The protein conversion efficiency decreased with the increase of dietary protein level. The energy conversion efficiency, however, did not show any relationship with dietary energy level. There was a greater improvement of growth performance due to simultaneous increase of dietary protein and energy level than that of increasing protein or energy alone.

An Energy Recovery Circuit for AC Plasma Display Panel with Serially Coupled Load Capacitance-SER1

  • Yang, Jin-Ho;Whang, Ki-Woong;Kang, Kyoung-Ho;Kim, Young-Sang;Kim, Hee-Hwan;Park, Chang-Bae
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.63-67
    • /
    • 2001
  • The switching power loss due to the panel capacitance during sustain period in AC PDP driving system can be minimized by using the energy recovery circuits. We proposed a new energy recovery circuit, SER1 (Seoul national univ. Energy Recovery circuit 1st). The experimental results of its application to a 42-inch surface discharge type AC PDP showed superior performance of SER1 in energy recovery efficiency and low distortion voltage waveform. Energy recovery efficiency of SER1 was measured up to 92.3 %, and the power dissipation during the sustain period was reduced by 15.2 W in 2000 pulse/frame compared with serial LC resonance energy recovery circuit.

  • PDF