• 제목/요약/키워드: EMTP (electro-magnetic transients program)

검색결과 53건 처리시간 0.024초

EMTP 시뮬레이션과 축소모형 실험에 의한 SSSC의 성능 해석 (New Performance Analysis of SSSC with EMPT Simulation and Scaled-model Experiment)

  • 강중구;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.524-530
    • /
    • 1999
  • This paper describes performance analysis techniques for SSSC using computer simulations with EMPT and experiments with a hardware scaled-model. A switching-level simulation model with EMTP was developed for the SSSC connected in series with the transmission line. The increase of transmission capability and dynamic performance was analyzed with the simulation model. The simulation results were reverified by experimental works with a hardware scaled-model. The developed analysis techniques can be used for designing and evaluating actual system of SSSC.

  • PDF

초전도 한류기의 회복특성에 따른 재폐로 동작 분석 (An Analysis of Recloser Operation According to Recovery Characteristics of Superconducting Fault Current Limiter)

  • 이상봉;김철환;김규호;김재철;현옥배
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.905-910
    • /
    • 2009
  • For proper application and operation of a SFCL(Superconducting Fault Current Limiter) in distribution systems, the prior investigation of fundamental characteristics and its effects analysis to the systems are very important. A point of view in coordination with recloser in distribution systems, characteristic about quenching and recovering of SFCL should be studied. Especially, its detailed study of recovery characteristic is particularly important to avoid conflict between the SFCL and the recloser. In this paper, the resistive type SFCL and recloser, which used in distribution system, were implemented using EMTP/ATPDraw and MODELS language. To analyze the recovery characteristics of SFCL according to recloser operation in distribution systems, case studies have been simulated and investigated.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

3-레벨 반브리지로 구성된 SSSC의 동특성 분석 (Dynamic Characteristic Analysis of 3-Level Half-bridge SSSC)

  • 박상호;하요철;백승택;김희중;한병문
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.317-324
    • /
    • 2001
  • 본 논문에서는 3-레벨 반브리지 인버터로 구성된 SSSC를 제안하였다. 제안한 SSSC의 동적특성을 분석하기 위해서 1기 무한모선 전력계통에 SSSC응 연결한 것을 가정하고 EMTP 시뮬레이션을 수행하였고, 축소모형 실험으로 그 특성을 확인하였다. 3-레벨 SSSC는 한 상당 6개의 단상 풀브리지 인버터로 구성되었고, PWM모드로 동작한다. 3-레벨 SSSC는 전압 주입을 위한 연계 변압기가 필요하지 않고, 전력계통에서 요구되는 동작전압에 EK라 브리지의 수를 가감하여 용이하게 구성할 수 있다.

  • PDF

펄스 플라스마 반응기에 대한 임피던스 및 누설 인덕턴스 분석 (Analysis of Impedance and Stray Inductance for Pulsed Plasma Reactor)

  • 최영욱;이홍식;임근희;김태희;김종화;장길홍;신완호;송영훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.253-260
    • /
    • 1999
  • In this paper, the impedance characteristic of wire-plate pulsed plasma reactor was investigated by experiment. The experiment have carried out under the several conditions of voltage, wire length and wire-plate distance. The impedance of reactor wad decreased with increasing voltage and wire length. The nature of discharge in reactor was changed from streamer corona to spark with increasing incident energy, from which we understood the critical energy density between the two discharges. Fromthis experiment, we proposed the method for the impedance matching between pulse generator and pulsed plasma reactor. Additionally, we succeeded in the analysis ofstray inductance of 0.5MW reactor using EMTP (ElectroMagnetic Transients Program). This means that EMTP is also useful for the analysis of inevitable stray inductance of forthcoming a large scale reactor.

  • PDF

분로리액터 개폐 과전압 해석을 위한 EMTP 모델링 (Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor)

  • 오승열;전인영;한기선;강지원
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.393-397
    • /
    • 2020
  • 무효전력 보상설비인 분로리액터는 전력계통의 부하 패턴에 따라서 하루에도 수 회 정도 차단기에 의해 운전되거나 정지된다. 분로리액터개폐 시 몇 가지 요인에 의해 발생하는 과전압은 차단기의 절연 성능을 저하시키며, 계통을 구성하는 전력기기에 심각한 전압 스트레스를 유발한다. 분로리액터 개폐 과정에서 발생하는 과도현상을 측정하는 것은 계통을 모의하여 차단기 성능을 검증하는 시험소 수준에서는 가능하나, 실제 계통 운전 중에 발생하는 과도현상을 측정하는 것은 여러 가지 제약으로 어려움이 있다. 따라서 본 논문에서는 실 계통에서 지상 소전류 차단과정에서 가혹한 과도회복전압(TRV: Transient Recovery Voltage)을 유발하는 재발호(reignition)나 전류재단(current chopping) 현상에 대한 해석을 위해 전자계과도해석프로그램(EMTP: Electro-magnetic Transients Program)을 활용한 모델링 과정과 이를 토대로 분로리액터 개폐 과정에서 차단기의 고장을 유발하는 주된 현상에 대해 해석하고자 한다.

345kV 계통 재투입과 전압 해석 (A Study on the Reclosing Overvoltage in 345 [kV] Transmission Line)

  • 윤재영;박동욱;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.166-169
    • /
    • 1990
  • The purpose of the circuit breaker on power system is to disconnect the faulty part from the system and to maintain the integrity of the system. With switching overvoltages are generated. When the system voltages become higher, switching overvoltage is important factor in insulation co-ordination. Since the no-load reclosing overvoltage with inductive source is severe, this paper deals with the reclosing overvoltage and the effect of closing resistor. This reclosing overvoltage of 27-bus model system with and without closing resistor is analyzed by using EMTP (Electro-Magnetic Transients Program) for both deterministic and Stochastic model.

  • PDF

배전계통에서의 상전도 및 초전도 한류기 특성에 관한 연구 (A Study of FCL and SCFCL Characteristics in Distribution System)

  • 방승현;박세호;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.145-147
    • /
    • 2007
  • 현재의 전력계통은 날로 커지고 복잡해지고 있으며 이에 따라 계통의 사고발생 시 고장전류도 크게 증가하고 있다. 따라서 된 논문에서는 사고 시 큰 고장 전류를 신속하게 제거하기 위한 방법으로 한류기를 적용하고 그에 따른 계통에서의 영향을 평가하였다. 또한 계통에서 한류기의 영향을 평가하기 위해서 EMTP-RV(Electro Magnetic Transients Program - Restructured Version)론 이용하여 한류기가 투입된 22.9kV급 배전계통에서 1선 지락고장이 발생하였을 경우, 상전도 및 초전도 전류기의 특성에 따른 배전계통의 영향을 모의시험 하였으며 그 결과를 분석하였다.

  • PDF

비선형 부하의 고조파로 인한 배전계통의 영향 분석 (Analysis of Harmonic Effects due to Non-linear Load in Distribution Systems)

  • 이호림;김현수;여상민;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2225_2226
    • /
    • 2009
  • An increasing of non-linear loads such as power electronic equipment in distribution systems is the reason for the greater concern about harmonics in recent time. A harmonic current and voltage in distribution systems can cause many problems such as malfunction of protective equipment. In this paper, Total Harmonic Distortion(THD) of voltage according to magnitudes and measurement locations of the non-linear loads was calculated and analyzed with Electro-Magnetic Transients Program(EMTP).

  • PDF

배전계통에서 차단기 개폐 시점에 따른 과전압 크기 분석 (The analysis of overvoltage according to the various switching time of circuit breaker in distribution system)

  • 김진현;성노규;여상민;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2197_2198
    • /
    • 2009
  • 최근 배전계통은 통신기술을 접목한 스마트 그리드로 발전 하면서 복잡한 네트워크를 이루고 있다. 이러한 영향으로 계통에서 발생하는 과도현상들 또한 복잡해짐에 따라 이에 대한 연구가 필요하다. 본 논문에서는 배전계통에서 차단기가 동작할 때 전원과 부하 사이의 거리에 따라 부하에서 발생하는 과전압 크기와 차단기 개폐 시점에 따라 부하에서 발생하는 과전압 크기를 EMTP(Electro Magnetic Transients Program)를 사용하여 모의하고 그 영향을 분석하였다.

  • PDF