• 제목/요약/키워드: EMTDC model

검색결과 235건 처리시간 0.019초

EMTDC에 의한 교류 전철급전시스템 사고 해석 (Fault Analysis of AC Electric Railway System Mode by EMTDC)

  • 이한민;오광해;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권9호
    • /
    • pp.521-527
    • /
    • 2003
  • This study presents the AC railway system modeled by EMTDC in detail. The ,model made by EMTDC have a lot of advantages. It could be available for the system change, simulated repeatedly and also applied regarding very complicated systems. EMTDC simulations to verify this model are compared with the hand calculations. It is confirmed that the model made by EMTDC is correctly designed.

전철 급전계통의 EMTDC 모델개발 (Development of EMTDC Model for Electrified Railroad Supply System)

  • 윤재영;최흥관;김종율
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권12호
    • /
    • pp.624-629
    • /
    • 2002
  • This paper presents the first Simulation model using EMTDC program to analyze the electrified train voltage distribution characteristics in ac auto-transformer 1110 railroads. In general, all of the electrified train supply system has the characteristics that the train supply line is a naturally non-symmetrical and unbalanced system. Also, it is needed to model the Scott transformer which invert the balanced 3-phase quantity into 2-phase. Therefore, the general simulation methodology using previous simplified equivalent circuit or RMS based program can't obtain the accurate results to reflect the real-time operation because these methodology is basically assumed on completely 3-phase balanced system. To overcome these defects, in this paper, the EMTDC simulation model to analysis the completely electrified railroad system with Scott transformer and AC auto-transformer is presented. Also, the correctness of EMTDC modeling is confirmed by the old basic concepts and we think that this EMTDC model has the future powerful capability for application of railroad system analysis.

전력계통 해석을 위한 PEMFC의 PSCAD/EMTDC 모델 (PSCAD/EMTDC Model of PEMFC for Power System Analysis)

  • 이종수;김학만;이병국;신명철
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.9-14
    • /
    • 2009
  • The modelling of PEMFC(Proton Exchange Membrane Fuel Cell) has been studied in many kinds of methods. But there are some limitations in application of the developed models to analyze transient phenomena of power systems. The PSCAD/EMTDC is very popular simulation tool in power system areas. To analyze power systems interconnected to PEMFCs, the PSCAD/EMTDC model of the PEMFCs is needed. In this paper, we developed a PSCAD/EMTDC model of PEMFC based on electro-chemical characteristic equations of PEMFC. Also, we performed simulations using the developed model in the PSCAD/EMTDC program and tested appropriateness of the proposed models. The simulations showed good results.

EMTDC용 IEEET3 여자기 모델 개발 (The development of IEEET3 Exciter system for implementation into EMTDC)

  • 허진;김동준;윤재영;문영환;이진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.123-125
    • /
    • 2001
  • In general, the PSS/E program is used for analyzing KEPCO System in terms of stability and the EMTDC Program is needed to analyze the transient characteristics of power system. The FSS/E provides various control models such as exciter. governor and PSS models whereas there ale few control of models in EMTDC. In this paper. we developed an EMTDC model for IEEET3 exciter which has been applied in KEPCO system. The EMTDC model is developed by examining PSS/E control block and using User Define Model in addition to default.lib provided by EMTDC we verify the correctness of developed IEEET3 model with PSS/E and EMTDC simulation results for the same test system.

  • PDF

EMTDC용 1차 에너지계 모델(TGOV5) 개발 (The development of TGOV5 model representing a steam turbine and boiler for implementation into EMTDC)

  • 허진;김동준;윤재영;문영환;이진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.282-285
    • /
    • 2001
  • In general, the PSS/E program based on RMS mathematical models is used for analyzing the steady state and transient stability phenomena of full-scale large power system. Whereas, the EMTDC program unlike PSS/E, studies the specific reduced small-scale power systems as a basis of instantaneous value mathematical models and used to analyze the Electro-Magnetic transient characteristics. The PSS/E provides various control models such as exciter, governor, PSS models and TGOV5 model but there are few control models in EMTDC. In this paper, we developed EMTDC model for TGOV5 of a steam turbine and boiler which represents governor action, main, reheat and low-pressure effects, including boiler effects. The EMTDC model is developed by examining PSS/E control block and using User Define Model(UDM) in addition to default.lib provided by EMTDC. We verify the correctness of developed TGOV5 model with PSS/E and EMTDC simulation results using Governor Step(GSTEP) method.

  • PDF

EMTDC 및 수 계산에 의한 교류 전철급전시스템 사고 해석 (Comparison of AC Electric Railway System Model using the EMTDC)

  • 이한민;오광해;한문섭;이장무;창상훈;장동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.395-398
    • /
    • 2003
  • This study presents wrong hand calculations for fault analysis at field on the real AC railway system. Hence, we correctly revised the hand calculations. We propose AC railway system model by using EMTDC. Fault studies are performed. We also compare revised hand calculations with EMTDC simulation to verify the proposed model made by EMTDC. So, we can confirm that the model made by using EMTDC is correctly designed.

  • PDF

순시치 해석용 전철급전계통 모델개발 (Model development of electrified railroad supply system for Electromagnetic Transient Analysis)

  • 윤재영;최흥관;김종율;위상봉
    • 한국철도학회논문집
    • /
    • 제5권4호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper presents the first simulation model using EMTDC program to analyze the electrified train voltage distribution characteristics in ac auto-transformer fed railroads. In general, all of the electrified train supply system has the characteristics that the train supply line is a naturally non-symmetrical and unbalanced system. Also, it is needed to model the Scott transformer which invert the balanced 3-phase quantity into 2-phase. Therefore, the general simulation methodology using previous simplified equivalent circuit or RMS based program can't obtain the accurate results to reflect the real-time operation because these methodology is basically assumed on completely 3-phase balanced system. To overcome these defects, in this paper, the EMTDC simulation model to analysis the completely electrified railroad system with Scott transformer and AC auto-transformer is presented. Also, the correctness of EMTDC modeling is confirmed by the old basic concepts and we think that this EMTDC model has the future powerful capability for application of railroad system analysis.

임계전류, 임계온도 및 회복시간을 고려한 초전도 전력케이블의 EMTDC 모델 컴포넌트 개발 (Development of EMTDC model component for HTS power cable considering critical current, critical temperature and recovery time)

  • 방종현;김재호;심기덕;조전욱;윤재영;박민원;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.39-44
    • /
    • 2006
  • Before applying HTS power cable to the real utility. system analysis should be carried out by some simulation tools . Hereby the electrical power system analysis is very important for practical use of HTS devices. Nowadays PSCAD/EMTDC simulation tool is one of the most popular and useful analysis tool for the electrical power system analysis. Unfortunately the model component for HTS power cable is not provided in the PSCAD/EMTDC simulation tool In this paper. the EMTDC model component for HTS power cable has been developed considering critical current, critical temperature and recovery time constant that depend on the sorts of HTS wire. The numerical model of HTS Power cable in PSCAD/EMTDC was designed by using the real experimented data obtained from the real HTS 1G wire test. The utility application analysis of HTS power cable was also performed using the developed model component and the parameters of the real utility network in this study. The author's got good results. The developed model component for HTS power cable could be variously used when the power system includes HTS power cable, especially it will be readily analyzed by PSCAD/EMTDC in order to obtain the data for the level of fault current power flow, and power losses, and so on.

간략화된 배터리 모델이 적용된 IUIa 충전 방식의 에너지 저장장치의 PSCAD/EMTDC 시뮬레이션 모델에 관한 연구 (A Study on the PSCAD/EMTDC Simulation Model of Battery Energy Storage with Simplified Battery Model and IUIa Charging Method)

  • 김성현;이계병;홍준희;손광명
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.84-90
    • /
    • 2010
  • In order to level electric power of the photovoltaic and wind-turbine system and ensure fast response of the fuel-cell and micro-turbine, the energy storage is required in the microgrid system. In this paper, a simplified simulation model of the battery energy storage for charging method with IUIa is developed using PSCAD/EMTDC. The model consists of e.m.f.(electromotive force), internal resistor and overvoltage capacitor. A method for deciding parameters of the model on a case-by-case basis is proposed. The developed model can be used in the simulation of a complicated system such as a microgrid system.

PSCAD/EMTDC를 미용한 계통연계형 태양광발전시스템의 모델링 및 모의 해석 (PSCAD/EMTDC Based Modeling and Simulation Analysis of a Grid-Connected Photovoltaic Generation System)

  • 전진홍;김응상;김슬기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권3호
    • /
    • pp.107-116
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMTDC, an industry standard simulation tool for studying the transient behavior of electric power system and apparatus, is used to conduct all aspects of model implementation and to carry out extensive simulation study. This paper is aimed at sharing with the PSCAD/EMTDC user community our user-defined model for PV system applications, which is not yet available as a standard model within PSCAD/EMTDC. An equivalent circuit model of a solar cell has been used for modeling solar array. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed.