• Title/Summary/Keyword: EMI Noise

Search Result 251, Processing Time 0.023 seconds

An efficient Method of Antenna Placement considering EMI between equipments on UAV (무인기 탑재 장비 간 상호 EMI를 고려한 효율적인 안테나 배치 방안)

  • Kim, Choon-Won;Kim, Ji-Hoon;Kwon, Kyoung-Il;Chung, Deok-Cho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.10
    • /
    • pp.987-994
    • /
    • 2011
  • This paper presents An efficient method of antenna placement considering EMI(Electromagnetic Interference) between equipments which are mounted on the UAV(Unmanned Air Vehicle). The analysis is accomplished for voice communication radio, control datalink, TCAS(Traffic Alert Collision & Avoidance System) and GPS(Global Positioning System) which are vulnerable to EMI because the frequencies are close to each other. There are two steps for analysis procedure : The first one is selecting antenna position on the UAV by monitoring return loss and pattern variation of each antenna. The second one is analyzing EMI via antennas between equipments. In the EMI analysis, spurious level of each transmitter, coupling level between antennas and system noise property are considered. This procedure can be used to predict EMI between equipments in development stage.

Conducted Noise Analysis of SMPS(Switching Mode Power Supply) (스위칭 모드 직류 전원공급기(SMPS)의 전도성 잡음해석)

  • 성주영;김윤명
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.286-291
    • /
    • 2000
  • 본 논문에서는 일반적인 EMI 노이즈 개요 및 SMPS(Switching Mode Power Supply)에서의 Noise 발생 메카니즘을 분석하고, 전도성 Noise를 측정하였으며, SMPS에서 발생되는 잡음행태를 분석하여 대책방법을 연구하였다.

  • PDF

EMI 기술동향 분석

  • Lee, Seong-Gyeong;Kim, Chang-Hee;Kim, Young-Tae
    • Electronics and Telecommunications Trends
    • /
    • v.3 no.4
    • /
    • pp.94-102
    • /
    • 1988
  • 정보화 및 자동화의 물결속에 전자noise 공해가 어느새 사회적인 문제로 대두되고 있다. 전자화시대의 필요악이라고까지 불리는 noise 문제는 이제 더이상 방치할수 없는 지경에 이르고 있으며 그 부작용은 알게 모르게 우리를 위협하고 있다. 전자noise에 대한 선진제국의 규제동향과 대표적인 시험방법을 소개한다.

A Study on Optimal Deployment for Improvement of EMI between MOSCOS and ES DF Antenna on a Surface Ship (수상함 MOSCOS와 ES 방향탐지 안테나간의 전자기 간섭 개선을 위한 최적배치 연구)

  • Chang, Hoseong;Son, Yoonjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • During the sea trial, we discovered EMI between MOSCOS and ES DF antenna. CW emitted by MOSCOS raised the threshold level of ES DF antenna. As a result, direction finding rate of ES has been decreased. This is a study for the improvement of EMI between the antennas mounted on a surface ship. An analysis is accomplished for MOSCOS, ES DF antenna and Jamming transmitter. This paper presents the method how to solve EMI based on the measurements and calculations about the ES DF antenna receiving level, MOSCOS radiation pattern and Jamming transmitter thermal noise. The test was performed with optimal deployment of MOSCOS on a surface ship. After changing the position of MOSCOS, EMI has been decreased significantly.

A New PWM Method for Conducted EMI Reduction in Inverter fed Motor Drive System (인버터 구동 시스템에서의 EMI 저감을 위한 새로운 PWM 구현)

  • Kun Hahm Nyon;Kim Lee-Hun;Jun Ki-Young;Chun Kwang-Su;Won Chung-Yuen;Han Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.384-388
    • /
    • 2004
  • High frequency common mode voltage produced by power inverters are a major cause of conducted EMI, creating motor ground currents, bearing currents and other harmful by products. This paper focuses on a new SVPWM method with random PWM injection to reduce conducted EMI noise. A New PWM technique associated with the common mode voltage can be significantly reducing and contributes to mitigate. The common mode voltage to $50\%$ in comparison with that for conventional SVPWM technique. Validation of the theory and reduction methods are then performed experiment ally based on an induction motor drive.

  • PDF

Reduction of Conducted EMI Noise in Boost Converter using Sigma-Delta Modulation Technique (Sigma-Delta 변조기법을 이용한 Boost Converter의 전도 노이즈 저감)

  • Lee Sung-Hee;Choi Tae-Young;Gu Ja-sung;Won Chung-Yuen;Kim Gyu-Sik;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.494-497
    • /
    • 2002
  • Conducted electromagnetic interference (EMI) from switch mode power supplies (SMPS) has become a major problem due to the proliferation of these devices employing dc-dc converters using standard pulse width modulation (PWM). In this paper, we proposed the sigma-delta modulation $({\sum}{\Delta}M)$ as an alternative switching technique to reduce the conducted EMI in SMPS. A comparative investigation on conducted EMI generated by PWM and ${\sum}{\Delta}M$ techniques are experimentally performed on a 300W Boost converter.

  • PDF

The Prediction of Conducted EMI In PWM Inverter Fed Induction Motor Drive System (PWM인버터-유도전동기 구동시스템의 전도노이즈 예측)

  • 안정준;이정호;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.579-588
    • /
    • 1999
  • This paper presents a technique for predicting the conductLu EMI(Electro Magnetic Interference) produced b by PWM inverter-induction motor drive system. To obtain the simulation models for prediction of conduct떠 n noise, high frequency model of an inverter leg with parasitic elements and multi-coil model of stator winding M are designed. Finally, the results are confirmLu from simulation and experiments.

  • PDF

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF

EMI Problem and Solutions of Unusual Harmonics in Low-Speed PCB (저속 PCB에서 이상 고조파의 EMI 문제 및 해결 방안)

  • Kim, Chan-Su;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.7
    • /
    • pp.636-645
    • /
    • 2015
  • In this paper, unusual harmonics noise problem of digital electronic products in mass production was introduced and a practical solution was proposed. Generally, 5th or higher harmonics noise level has been ignored in circuit designs because over 5th harmonics noise decreases by 40 (dB/decade). Through some measurements, it is confirmed that over 10th harmonics noise can propagate and radiate in case of a certain PCB or housing conditions. We propose a capacitively loaded micro-strip low pass filter for commercial products having spatial design constraints and measured the effectiveness. The proposed structure can solve both of the continual increment of harmonics noise level and the spatial design constraint of commercial products. We expect the proposed method be effectively used for various digital electronic products.

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.