Soft-Switching Buck-Boost Converter with High Power Factor for PAM Inverter System

  • K. Taniguchi;T. Watanabe;T. Morizane;Kim, N. ura;Lee, Hyun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.264-269
    • /
    • 1998
  • A proposed soft-switching buck-boost PWM converter has a lot of advantages, Viz., electric isolation, a high power factor, low switching losses, low EMI noise, reduction of the voltage and current stresses, etc. In a new PFC converter, the switching device is replaced by the loss-less snubber circuit to achieve the zero voltage switching (ZVS) at the maximum current. However, the charging current of the capacitor in the loss-less snubber circuit distorts the input current waveforms. To improve the input current waveform, a new duty factor control method is proposed in this paper.

  • PDF

Experimental Waveforms of Single-Pulse Soft-Switching PFC Converter

  • Taniguchi, Katsunori;Koh, Kang-Hoon;Lee, Hyun-woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.1002-1007
    • /
    • 2003
  • A new driving circuit for the SPSS (Single-Pulse Soft-Switching) PFC converter is proposed. The switching device of a SPSS converter switches once In every half cycle of an AC commercial power source. Therefore, it can be solved many problems caused by the high frequency operation. The proposed SPSS converter achieves the soft-switching operation and the EMI noise can be reduced. The resonant capacitor voltage supplies to the resonant inductor even if the input AC voltage is the vicinity of zero cross voltage. Then, the power factor and input current waveform can be improved without delay time. A new driving circuit achieves the operation of SPSS converter by one switching drive circuit. The proposed converter can be satisfied the IEC standard sufficiently.

  • PDF

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

DSP를 사용한 PMSM 초고속 전동기 제어기에 관한 연구 (A Study on the controller for a high speed PMSM using DSP)

  • 오동섭;오성업;박민호;성세진;김인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.39-41
    • /
    • 2005
  • In this paper, a study on the controller for high speed PMSM (Permanent Magnet Synchro-nous Motor) is described. PMSM can be driven over 50,000 rpm because it has no brush and commutator structure. It also has less EMI noise and easy cooling structure compare to the other motors. The controller was designed to have a capability to drive 20kw, 42,000rpm high speed motor system. A senseless vector control method was studied based on d-q conversion theory to have a high driving efficiency. The control board was designed using TMS320C33 and the performance was verified by experimental results on driving the inverter and motor system.

  • PDF

스위칭 주파수의 대역 확산을 통해 전자방해잡음을 저감할 수 있는 LLC 공진형 컨버터 (LLC Resonant Converter using Spread Spectrum Technique for Reducing EM Noise)

  • 김민아;박화평;정지훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.162-164
    • /
    • 2018
  • 스위칭 주파수의 대역 확산 (Spread Spectrum) 기법은 전력 변환 장치의 전자 방해 잡음 (Electromagnetic Interference; EMI)를 줄일 수 있다. 하지만 공진형 컨버터는 스위칭 주파수 가변을 통해 출력 전압을 제어하기 때문에 스위칭 주파수의 대역 확산 기법을 적용하게 되면 출력 전압이 크게 흔들리게 된다. 본 논문은 LLC 공진형 컨버터에 대역 확산 기법을 사용함과 동시에 확산된 스위칭 주파수 대역의 위상 제어를 통해 출력 전압을 제어하는 방법을 제시하고자 한다. 제안하는 출력 전압 제어 성능 향상 및 전자방해잡음 감소 성능은 500 W 프로토타입 컨버터를 사용하여 검증하고자 한다.

  • PDF

무손실 스너버회로를 이용한 새로운 소프트 스위칭 AC-DC승압형 컨버터 (The new Soft-Switching AC-DC Boost Type Converter using Lossless Snubber)

  • 문상필;서기영;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1226-1228
    • /
    • 2004
  • A novel lossless passive snubber is proposed for soft switching the boost type converters. The proposed snubber does not use any auxiliary switches. but uses two identical snubber capacitors which are charged in parallel at turn off of the main switch and discharged in series at turn on automatically, and the discharged energy is recovered effectively (more than $95[\%]$ recovery) into the output capacitor. Thus, the snubber provides zero voltage switching for the converter main switch, reducing both the turn off losses and the electromagnetic interference(EMI) noise, whitch improves the converter performance. The experimental results of a 20[kHz] 600[W] DC-DC boost converter and a single-phase AC-DC boost rectifier with the new snubber are presented.

  • PDF

소프트 스위칭 방식을 갖는 2㎾ PFC 컨버터의 분석 설계 및 실험 비교 (Analysis, Design and Experimental Comparison of 2㎾ Power Factor Corrector Converters With Soft-Switching Methods)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.537-544
    • /
    • 2002
  • This paper describes a comparative analysis of soft switching boost converters through design, production and experiment. Soft switching boost converters are designed to satisfy the condition of input voltage 170-265Vac, output voltage 400Vdc, output current 5A, output power 20W-2000W and unit power factor. In addition, parameter values are designed so that system operation can be compared under this is similar conditions. The efficiency of the combined inductor soft switching boost converter was 97.63% with 1011 load better than that of other boost converter types. The combined inductor soft switching converter has simple circuit construction and low switching loss. EMI resulted by the switching noise, and harmonic distortion.

연속전류모드를 위한 새로운 순회복 게이트 드라이브 (A NEW SOFT RECOVERY DRIVE FOR CONTINUOUS CONDUCT10N MODE)

  • 김학성;정용채;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.806-808
    • /
    • 1993
  • New soft recovery drive which can alleviate the loss due to reverse recovery of diode is proposed. By using this drive, the reverse current of the diode is minimized and stabilized because there is inner local feedback loop between the turn-on current of the power MOSFET and the reverse recovery current of the diode. The loss and EMI noise can be considerably reduced in this way. Brief operational principle and experimental results are included to verify the usefulness.

  • PDF

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

변형률 센서를 이용한 구조물의 동적 모니터링 (Dynamic monitoring of structures using strain sensors)

  • 최성훈;은종필;강동훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.387-392
    • /
    • 2009
  • Measurement of dynamic characteristics are widely used to detect defects in mechanical or civil structures. The most common approach is to measure changes in frequency spectrum or mode shapes using accelerometers. An alternative to using mode shapes is using stain modes. Strain is more sensitive to local defects than displacement, and hence stain modes measurement is an efficient in structural health monitoring. This paper deals with dynamic monitoring of a beam structure using strain sensors. Resistive strain gages and FBG strain gages are used and their characteristics are compared. It has been known that resistive strain gages are week to EMI environment and suffers from noise at high frequency range. It has been shown that the FBG sensor is a good alternative that overcomes such difficulties.