• Title/Summary/Keyword: EMG-measurement

Search Result 175, Processing Time 0.032 seconds

Research of Body Pressure Distribution Change with the Use of BackJoy and Satisfaction of Human Sensibility

  • Kim, Kwangoh;Yoon, Jungmin;Ahn, Sungyong;Kim, Daseuran;Park, Peom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effect of BackJoy on how it effectively reduces the physical load generated in a posture in which the user sits, increases user's comfort and satisfaction, and maintains the correct posture. Background: Because of development of science and economic development, most office workers and students spend about 75% of their working time in chairs. However most of them have a poor posture. Method: This experiment conducted measurement using a pressure mat and surveyed to evaluate fatigue level, satisfaction and comfort of sit. The study is experimented 20 male and 14 female participants. The participants carried out four different types of tasks and each task took 20 minutes long. Results: In the case of experiment results before and after the use of BackJoy, average pressure, contact area and pressure per unit area appear to prove that using BackJoy is more effective. Conclusion: Through this study, the BackJoy's effects for the maintenance of good posture and loads that occur in the body are reduced. In the future study, there are some researches needed for various verifications using an EMG sensor that shows loads of vertebrae and we need to analyze each group of the participants by dividing them. Application: The evaluation method used in this study can be applied to evaluating ergonomic chairs.

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

Biomechanical Analysis of Muscle Fatigue and Ground Reaction Force for the Development of Outdoor Walking Shoes

  • Jang, Young-Min;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.413-420
    • /
    • 2016
  • Objective: The purpose of this study was to analyze and compare different kinds of outdoor walking shoes in terms of muscle fatigue and ground reaction force on walking, and to provide foundational data for developing and choosing outdoor walking shoes that fit the users. Method: The study subjects were 30 healthy men. The experiment was conducted by using outdoor walking shoes with different inner and outer harnesses of the midsole, and shapes of the outsole. For data collection, electromyography was used to measure the muscle fatigue of the anterior tibial muscle and gastrocnemii, which contribute to the dorsiflexion and plantarflexion of the ankle joint, and the biceps muscle of the thigh and lateral great muscles, which contribute to the flexion and extension of the knee joint. A GRF measurement device was used to measure the X, Y, and Z axes. Results: In the type A outdoor walking shoes, regarding the hardness of the midsole, the inner part was soft, while the outer part was hard. The vertical ground reaction force was the lowest, which means least impact while walking and light load to the knees and ankles. The type C outdoor walking shoes were intended to provide a good feel in wearing the shoes. The tibialis anterior, biceps femoris, and gastrocnemii indicate low fatigue, which means that during a long-distance walk, it will minimize the fatigue in the muscles of the lower limbs. Conclusion: To sum up the study results, the different types of outdoor walking shoes indicate their unique characteristics in the biomechanical comparison and analysis. However, the difference was not statistically significant. Thus, a systematic and constant follow-up research should be conducted to cope with expanding market for outdoor walking shoes. Lastly, this study is expected to present foundational data and directions for developing outdoor walking shoes.

Effects of Neuromuscular Electrical Stimulation Training on Abdominal Fat, Trunk Muscle Thickness and Activity in Middle-Aged Women with Abdominal Obesity (전기근육자극 훈련이 복부비만 중년 여성의 복부지방, 체간 근 두께와 활성도에 미치는 영향)

  • Yoo, Seung-Ah;Yoo, Kee-Ung;Lim, Chang-Ha;Kim, Chang-Yong;Kim, Hyeong-Dong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.2
    • /
    • pp.125-135
    • /
    • 2019
  • PURPOSE: This study examined the effects of low frequency neuromuscular electrical stimulation (NMES) training on abdominal obesity in middle-aged women through electromyography and ultrasound. METHODS: Twenty-two middle aged women with abdominal obesity participated in the study. A low-frequency NMES device was used on the abdomen and waist of each subject for 20 minutes each (a total of 40 minutes) three times a week for eight weeks. The waist-hip ratio (WHR), weight and BMI (Body Mass Index) were measured. Electromyography (EMG) and ultrasound measurements were performed three times in total (pre-intervention, four weeks into the intervention, and eight weeks post-intervention) to examine the effects of low-frequency NMES on the abdominal muscle activity, muscle thickness, and subcutaneous fat. RESULTS: The results indicated a difference in the WHR and waist circumference before and after intervention (p<.05). The external oblique muscle (EO) showed a significant increase in muscle activity during all measurements taken post-intervention (p<.05). The abdominal subcutaneous fat thickness also showed a significant decrease between each measurement (p<.05). The test results showed that the abdominal subcutaneous fat thickness values taken eight weeks post-intervention were significantly lower than those taken pre-intervention and four weeks into the intervention (p<.05). CONCLUSION: These findings show that low-frequency NMES device training can be applied to middle-aged women with abdominal obesity to improve their body shape and exercise performance.

Pilot Test of Electrocardiogram Measurement Method for Conductive Textiles Electrode Position in Bed Condition (침대 형태에서 기능성 직물 전도성 전극 위치에 대한 심전도 측정 방법의 Pilot Test)

  • Jun won, Choi;Lina A., Asante;Chang Hyun, Song;Halim, Chung;Han Sung, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.80-84
    • /
    • 2023
  • Electrodes are one of the types of biosensors capable of measuring bio signals, such as electrocardiogram (ECG) and electromyogram (EMG) signals. These electrodes are used in various fields and offer the advantage of being able to measure ECG signals without the need for skin attachment, compared to Ag/AgCl electrodes. The purpose of this study was to evaluate the efficacy of conductive textile electrodes in collecting ECG signals in a bed-like environment. Three adult participants were involved, and a total of 30 minutes of ECG signals were collected for each participant. The collected ECG signals were analyzed to determine the heart rate, normLF and a comparison was made between the conductive textile electrodes and Ag/AgCl electrodes. As a result, the change in heart rate and normLF could be observed, and in particular, the difference between the two electrodes decreased. This study confirmed that conductive textile electrodes can effectively collect ECG signals in a bed-like environment. It is hoped that this research will lead to the development of a system that can detect various sleep-related diseases through the use of these electrodes.

Effects of Heel Raising Exercise whith Kinesio Taping on Triceps Surae Muscle Activity and Balance in 20s Adults (키네시오 테이핑을 결합한 발 뒤꿈치 들기 운동이 건강한 성인의 하지 근활성도 및 균형에 미치는 영향)

  • Geun Hwan, Jang;Tae Sung, In;Kyung Hun, Kim
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.4
    • /
    • pp.17-26
    • /
    • 2022
  • Background: The aim of this study was to investigate the effects of heel raising with kinesio taping (HRKT) on triceps surae muscle activity and balance in 20s adults. Design: Two groups pre-post randomized controlled design. Methods: The total of 40 subjects were randomly divided in the HRKT group (experimental group, n=21) and heel raising with sham kinesio taping (control group, n=19). Both groups receive heel raising with kinesio taping and sham kinesio taping for 20 minutes a day, five day per week, for four weeks. Measurement were performed before training and 4 weeks after training. The triceps surae muscle activity was measured using the EMG. A functional reach test (FRT) was used to evaluate balance ability. The independent t-test was conducted to compare exercise methods depending on the taping effect on each group. Results: The both group showed significant differences in muscle activity of lower extremity and functional reach test in the pre-post intervention comparison (p<0.05). The experimental group showed significantly more improvement in triceps surae muscle activity and functional reach test compared to the control group(p<0.05). Conclusion: We confirmed that the effects of heel-raising with kinesio taping group on triceps surae muscle activity and balance ability in 20s adults. The result suggest that heel raising with kinesio taping for 20s adults should be further studied and considered.

Effects of Draw-In Bridge Exercise with Taping or Visual Feedback on Abdominal Muscle Activity (테이핑 또는 시각적 피드백을 병행한 드로우-인 교각운동이 복부 근활성도에 미치는 영향)

  • Won-Sik Bae;Hwa-Gyeong Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.177-186
    • /
    • 2024
  • Purpose : The purpose of this study was to use oral instruction and taping to induce abdominal draw-in in the previous study, but there is a lack of research on the comparison of effects. Therefore, in this study, we would like to study how the effect of oral instruction, taping, and no feedback can affect muscle activity when performing abdominal draw-in pier exercises. Methods : Before the experiment, group A trained piers and applied only draw-in piers, group B applied taping feedback, and group C were divided into three groups per week for six weeks, and three sets of contractions for five seconds per group were performed five times, and a minute break was provided between each exercise. As a measurement tool, a wireless surface electromyography (EMG) was used to measure surface electromyography (Telemyo-DTS, NORAXON, USA) that derives a synthetic unit of muscle using a surface electrode. For statistical processing of data, the analysis is performed using the SPSS/PC Version 25.0 statistical program for Windows, and the statistical significance level is a=.05 Results : First, the duration was somewhat shorter in order to more accurately compare the muscle activity of the core muscles. Therefore, future research needs to be research that can be exercises with precise biofeedback and taping applied over a longer period of time. Secondly, it is believed that there is no significant difference, since the subjects were studied in healthy young adult men and women, not patients. Thirdly, they could not control the daily life of the subjects. Through future research, it is necessary to analyze the correlation between muscle activity and abdominal muscle thickness by adding ultrasound in addition to muscle activity in various age groups. Conclusion : During draw-in bridge exercise according to feedback, the muscle activity of the back muscle increased, and there was no significant difference in the muscle activity of the back muscle according to each feedback. Therefore, both the feedback applied during the draw-in pier exercise and the control group are effective in changing the thickness of the abdominal muscles.

Development of Wireless Ambulatory System Measuring 3-D Motion as Podiatric Diagnosis (족부 진단용 3차원 움직임 측정을 위한 무선 이동형 시스템 개발)

  • Kim, Jin-Ho;Kim, Hwa-In;Kim, Dong-Wook;Won, Yong-Gwan;Kim, Jung-Ja
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5B
    • /
    • pp.502-510
    • /
    • 2011
  • In this research, a wireless movable systems is introduced that is applicable for real-world clinical examination in order to resolve the inconvenience of wired motion analysis system which uses markers by measuring more accurately the angle of the 3D motion. The system is composed of bluetooth data transmission and 6 DOF inertial measurement system that is composed of 3-axis acceleration and 3-axis gyroscope. The samples were collected from 10 feet of 5 young children who were confirmed as patients having flat feet and achilles tendonitis by podiatric expert in pediatrics, and the validity of the system was evaluated by comparison with the opinion by the expert using the EMG data and the data measured by the developed system. ROM of ankle was measured by the difference between the maximum and the minimum peaks of 3-axis values (pitch, roll and yaw) measured at lateral malleolus bone, and based on this measured value, the eversion rate became relatively higher as flat feet state become worse, which is equivalent to the opinion from the podiatric experts. It was shown that there is a relation between the certain muscle activities and the abnormal motion of foot caused by disease.

A Study of Surface Electromyography Measurement of Wrist Exercise (Extension, Flexion, Grasping) in Healthy People (정상인의 완관절 신전, 굴곡, 악력(握力) 시 표면근전도 측정 연구)

  • Kim, Seok Hee;Lee, Kyung Jin;Choi, Yoo Min;Kim, Ju Yong;Yook, Tae Han;Lee, Sang Lyoung;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : This study aimed to prove that surface electromyography(SEMG) can be used to identify the degree of symptoms of diseases in the upper extremities; it also aimed to confirm various potential therapeutic effects through an inquiry into the value measured by the SEMG on certain acupuncture points in the upper extremities. Methods : Fifty healthy people received instructions for the method of exercise: wrist flexion, extension and hand grasping. Disposable electrodes were attached to acupuncture points of Susamni($LI_{10}$), Naegwan($PC_6$), Oegwan($TE_5$) and below Sohae($HT_3$) two cun on both sides in flexion, extension and grasping to measure the SEMG values. The research results were analyzed using SPSS statistics Ver. 22.0(IBM, USA). Results : The average value was highest on Naegwan($PC_6$) in grasping, and the average SEMG value was higher in the order of grasping, extension and flexion. The asymmetry index of each point was Susamni($LI_{10}$) $16.26{\pm}13.59%$, Oegwan($TE_5$) $20.38{\pm}15.59%$, below Sohae($HT_3$) two cun $20.89{\pm}16.77%$, Naegwan($PC_6$) $22.49{\pm}14.91%$ in wrist extension, Susamni($LI_{10}$) $25.99{\pm}21.44%$, Oegwan($TE_5$) $21.15{\pm}15.94%$, below Sohae($HT_3$) two cun $19.62{\pm}15.46%$, Naegwan($PC_6$) $19.93{\pm}16.85%$ in wrist flexion, Susamni($LI_{10}$) $16.60{\pm}12.21%$, Oegwan($TE_5$) $10.94{\pm}8.29%$, below Sohae($HT_3$) two cun $15.20{\pm}12.60%$, Naegwan($PC_6$) $11.68{\pm}7.77%$ in grasping. Conclusions : In this study, to identify the degree of symptoms of diseases in the upper extremities and confirm therapeutic effects, it is necessary to analyze the calculated percentage and compare the SEMG measurement of special points with those of other points, and with the asymmetry index.