Biomechanical Measuring Techniques for Evaluation of Workload (작업부하 평가를 위한 생체역학적 측정방법)

  • Kim, Jung-Yong;Park, Ji-Soo;Cho, Young-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.445-453
    • /
    • 2010
  • It is necessary to quantitatively evaluate the workload of workers in order to improve the level of safety and efficiency as well as to prevent workers from musculoskeletal disorders. The purpose of this study is to introduce biomechanical methods that are largely used to quantitatively evaluate workload. The biomechanical methods use kinematics and kinetics to analyze the movement and force of biomechanical body. Motion analysis, joint angle measurement, ground reaction force, mathematical model, and electromyography (EMG) were introduced as a tool or device for biomechanical evaluation. In this study, the special feature of each method was emphasized and important tips for field measurement were summarized. The information and technique disclosed in this summary can be used to evaluate and design the workplace better by effectively control the workload of field workers.

A Study on the Muscle Activity During Asymmetric Load Handling (허리의 비틀림 각도에 따른 근육 활동 분석)

  • 장성록;박현진
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.117-120
    • /
    • 2001
  • Low back pain has been known as the most frequent musuculoskeletal disorders in modern industrial society and cost by low back pain is increasing mon and more. The asymmetric lifting has been identified as a major risk factor of low back pain. In this study, the muscle activity and muscle exertion level during asymmetric load handling (without trunk flexion) was estimated. The results of normalized MVC measurement were decreased about 16%, 24%, 34% respectively as the asymmetric angle was $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. From the results of EMG measurement contralateral muscles were more active than ipsilateral muscles. RMSEMG values of right erector spinae muscles were decreased as the work posture went to 90$^{\circ}$ and those of left erector spinae muscles were increased until the asymmetric angle was 40$^{\circ}$ but decreased continually over 40$^{\circ}$. And for seven of subjects, activities of left and right latissimus dorsi muscles were maintained constantly, while for remainer, those were irregular.

  • PDF

Biological Signal Measurements in SiMACS (SiMACS에서의 생체신호 수집)

  • Lim, J.J.;Choi, Y.S.;Kim, D.H.;Kim, E.J.;Lee, H.J.;Woo, E.J.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.53-56
    • /
    • 1994
  • We have developed biological signal measurement modules and data acquisition and control card for a biological signal measurement, archiving, and communication system (SiMACS). Biological signals included in this system are ECG, EEG, EMG, invasive blood pressure, respiration, and temperature. Parameters of each module can be controlled by PC-base IDPU (intelligent data processing unit) through a data acquisition and control card. The data acquisition and control card can collect up to 16 channels of biological signals with sampling rate of $50\;{\sim}\;2,000Hz$ and 12-bit resolution. All measurement moduls and data acquisition functions are controlled by microcontroller which receives commands from PC. All data transfers among PC, microcontroller, and ADC are done through a shared RAM access by polling method for real rime operation.

  • PDF

The Effect of Different Elastic Tape Expansibilities on the Onset Time of Muscle Contraction during Neck Extension for Forward Head Posture Syndrome (목 폄 시 탄력성 테이프의 신장력 차이가 전방머리자세 증후군의 근수축 개시시간에 미치는 영향)

  • Yoon, Jung-Gyu
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.331-340
    • /
    • 2022
  • Purpose: Thisstudy aimed to identify the effect of varying the expansibility of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. Methods: Forty-five young adults with forward head posture syndrome volunteered to participate and were randomly assigned to one of three groups according to the expansibility of the elastic tape (25%, 50%, 75%). The onset time of muscle contraction for the neck extensor during neck extension was measured using an electromyographic system (Free EMG, BTS, Italy). Multivariate analysis of variance was employed to determine the effect of different expansibilities of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. When there was a statistically significant difference by MANOVA, Scheffe was used as a post-hoc test. The level of significance was set at α=0.05. Results: In the comparison of the onset time of muscle contraction of varying elastic tape expansibilities and measurement times, there was a significant difference between the groups (Lt. UT, Lt. SCM, Rt. SCM) (p < 0.05), but there was no significant difference in the interaction between the measurement time and the group, between the measurement time (p > 0.05). Conclusion: In the neck extension, 75% of the tape extensibility in the Lt. UT and both SCM shortened the muscle contraction onset time.

Changes of Surface Temperature and Electromyography Activities by Local Heat and Cold (온열과 냉의 국소적용에 의한 체표면 온도와 근전도 활동의 변화)

  • Choi, Seok-Ju;Lim, Sang-Wan;Kim, Su-Hyon;Mun, Dal-Ju
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.61-72
    • /
    • 2007
  • INTRODUCTION: Local heat and cold application has been frequently used as means of muscle relaxation and blood circulation or reinforcing muscle strength, relaxing muscle tension in clinical situation. In particular, it has been known that long-term heat and cold application for relaxing muscle tension inhibits muscle spasticity or tension. But, it has been rarely reported that what influences of heat and cold application on activation of muscle action potential. Therefore, this study aims to analyze surface temperature and electromyography activities according to the heat and cold application. METHODE: Subjects of this research were 10 normal men and women (5 men, 5 women). Hot pack and cold pack was applied to vastus medialis muscle of thigh and rectus femoris muscle for 20 min. Surface temperature of vastus medialis muscle and rectus femoris muscle was measured, knee joint of subjects was in $45^{\circ}$ flexion, sitting on a chair, maximal isometric contraction was induced, surface electromyography (sEMG) signals were collected and root mean square (RMS) and median frequency (MOF) were analyzed. All measurements were conducted before and immediately after experiment, 10 min., 20 min. and 30 min. after experiment. Data were analyzed with SPSS 12.0 program, comparison of changes in superficial temperature and sEMG signals through repeated measurement was conducted with repeated measures ANOVA and significance level $\alpha$ was 0.05. RESULTS: Changes of surface temperature of vastus medialis muscle according to cold application were radically decreased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=72.216, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=88.930, P<0.001). Changes of surface temperature of vastus medialis muscle according to heat application were radically increased immediately after application, but it was recovered after 30 min. of application and it showed significant difference (F4. 36=27.267, P<0.001). Surface temperature of rectus femoris also showed radical decrease immediately after application, but it was recovered after 30 min. of application and showed significant difference (F4. 36=19.774, P<0.001). Changes of sEMG by heat and cold application were no statistical difference. Surface temperature of skeletal muscle after heat and cold application showed significant change for 30 min., but it was found that increase or decrease of surface temperature had not great influence on sEMG activities.

  • PDF

Isolated Activation of the Upper Trapezius in Three Manual Muscle Testing Position : Convergence Study (세 가지 도수근력 검사 자세에서 상부 승모근의 독립적 수축 : 융합적 연구)

  • Ha, Sungmin
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.83-88
    • /
    • 2020
  • The purpose of this study was to investigate the optimal position among three manual muscle tested positions for upper trapezius in which to obtain an isolated upper trapezius EMG signal for the normalization of upper trapezius muscle EMG activity. A total of 28 healthy adult men participated in the experiment. The UT (upper trapezius) and LS (levator scapulae) muscle activities were measured using the TeleMyo 2400T and analyzed using MyoResearch software. The muscle activity of the US and LS was measured by performing three manual muscle test positions for the upper trapezius. The UT/LS ratio during the S-MVIC was 80.25 and was significantly higher than that during the T-MVIC (76.50; p = 0.011) and the C-MVIC (60.95; p < 0.001). And, the UT/LS ratio during the T-MVIC and was significantly higher than that during the C-MVIC (p < 0.001). Based on the results of present study, we suggest a switch from T-MVIC to S-MVIC for the independent normalization reliability of upper trapezius EMG activity. The UT muscle strength or normalization test using S-MVIC will be able to measure muscle strength or activity of UT compared to previous measurement methods.

A Biomechanical Comparative Analysis between Single-Radius and Multi-Radius Total Knee Arthroplasty for Sit-to-Stand Movement (앉았다 일어나는 동작동안 단축회전반경 무릎인공관절 수술자와 다축회전반경 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan
    • Journal of Life Science
    • /
    • v.16 no.5
    • /
    • pp.773-779
    • /
    • 2006
  • Eight of the individuals had a unilateral S-RAD TKA and Multi-Radius TKA ($Scorpio^{TM}$ PS, Howmedica-Osteonics, Inc.). The instrument were used Peak Motion Measurement $System^{TM}$, $MYOPAC^{TM}$EMG System, KIN-COM $III^{TM}$ System. The Figure 3 shows that the average time for the S-RAD group to accomplish the sit-to-stand movement was 1.59 s, which was 0.19 s less than the M-RAD group (p= 0.033). In Figure 5, the S-RAD TKA group tended to have $7^{\Omega}{\cdot}S^{-1}$ less trunk flexion velocity than that of the M-RAD group (p= 0.058). The Figure 6 shows that the S-RAD TKA limb tended to have less ADD displacement (p = 0.071) than that of the M-RAD TKA limb. We failed to find significant differences for ABD and ADD displacements between the S-RAD and M-RAD N-TKA limbs (p= 0.128 and 0.457, respectively). The VM of the S-RAD TKA limb demonstrated significant less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $15^{\Omega}$ of knee flexion (p 0.05). The VL of the S-RAD TKA limb also demonstrated significant less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $45^{\Omega}$ of knee flexion (p 0.05). Similar to the VM and VL, the RF of the S-RAD TKA limb showed less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $30^{\Omega}$ of knee flexion (p 0.05).

Electroencephalogram(EEG) Activation Changes and Correlations of signal with EMG Output by left and right biceps (좌우 이두근의 근전도 출력에 따른 뇌파의 활성도 변화와 관련성 탐색)

  • Jeon, BuIl;Kim, Jongwon
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.727-734
    • /
    • 2019
  • This paper confirms whether the movement or specific operation of the muscles in the process of transferring a person from the brain can find a signal showing an essential feature of a certain part of the brain. As a rule, the occurrence of EEG(Electroencephalogram) changes when a signal is received from a specific action or from an induced action. These signals are very vague and difficult to distinguish from the naked eye. Therefore, it is necessary to define a signal for analysis before classification. The EEG form can be divided into the alpha, beta, delta, theta and gamma regions in the frequency ranges. The specific size of these signals does not reflect the exact behavior or intention, since the band or energy difference of the activated frequencies varies depending on the EEG measurement domain. However, if different actions are performed in a specific method, it is possible to classify the movement based on EEG activity and to determine the EEG tendency affecting the movement. Therefore, in this article, we first study the EEG expression pattern based on the activation of the left and right biceps EMG, and then we determine whether there is a significant difference between the EEG due to the activation of the left and right muscles through EEG. If we can find the EEG classification criteria in accordance with the EMG activation, it can help to understand the form of the transmitted signal in the process of transmitting signals from the brain to each muscle. In addition, we can use a lot of unknown EEG information through more complex types of brain signal generation in the future.

Multimodal Bio-signal Measurement System for Sleep Analysis (수면 분석을 위한 다중 모달 생체신호 측정 시스템)

  • Kim, Sang Kyu;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.5
    • /
    • pp.609-616
    • /
    • 2018
  • In this paper, we designed a multimodal bio-signal measurement system to observe changes in the brain nervous system and vascular system during sleep. Changes in the nervous system and the cerebral blood flow system in the brain during sleep induce a unique correlation between the changes in the nervous system and the blood flow system. Therefore, it is necessary to simultaneously observe changes in the brain nervous system and changes in the blood flow system to observe the sleep state. To measure the change of the nervous system, EEG, EOG and EMG signal used for the sleep stage analysis were designed. We designed a system for measuring cerebral blood flow changes using functional near-infrared spectroscopy. Among the various imaging methods to measure blood flow and metabolism, it is easy to measure simultaneously with EEG signal and it can be easily designed for miniaturization of equipment. The sleep stage was analyzed by the measured data, and the change of the cerebral blood flow was confirmed by the change of the sleep stage.

The Comparison of Sensitivity of Numerical Parameters for Quantification of Electromyographic (EMG) Signal (근전도의 정량적 분석시 사용되는 수리적 파라미터의 민감도 비교)

  • Kim, Jung-Yong;Jung, Myung-Chul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.3
    • /
    • pp.330-335
    • /
    • 1999
  • The goal of the study is to determine the most sensitive parameter to represent the degree of muscle force and fatigue. Various numerical parameters such as the first coefficient of Autoregressive (AR) Model, Root Mean Square (RMS), Zero Crossing Rate (ZCR), Mean Power Frequency (MPF), Median Frequency (MF) were tested in this study. Ten healthy male subjects participated in the experiment. They were asked to extend their trunk by using the right and left erector spinae muscles during a sustained isometric contraction for twenty seconds. The force levels were 15%, 30%, 45%, 60%, and 75% of Maximal Voluntary Contraction (MVC), and the order of trials was randomized. The results showed that RMS was the best parameter to measure the force level of the muscle, and that the first coefficient of AR model was relatively sensitive parameter for the fatigue measurement at less than 60% MVC condition. At the 75% MVC, however, both MPF and the first coefficient of AR Model showed the best performance in quantification of muscle fatigue. Therefore, the sensitivity of measurement can be improved by properly selecting the parameter based upon the level of force during a sustained isometric condition.

  • PDF