포도밭에 대한 비점오염원 유출특성 해석 (Analysis of Nonpoint Sources Runoff Characteristic for the Vineyard Areas)

  • 윤영삼;이상협;유재정;이재관
    • 한국환경과학회지
    • /
    • 제20권3호
    • /
    • pp.361-372
    • /
    • 2011
  • This study analyzed the characteristics of stormwater runoff by rainfall type in orchard areas for two years. Effluents were monitored to calculate the EMCs and runoff loads of each pollutant. The runoff characteristics for nonpoint sources from vineyards were also inspected based on independent variables that affect runoff such as rainfall and rainfall intensity. The average runoff loads of each pollutant from vineyard_A and vineyard_B were found as follows: BOD 39.13 mg/$m^2$, COD 112.13 mg/$m^2$, TOC 54.98 mg/$m^2$, SS 1,681.8 mg/$m^2$, TN 18.29 mg/$m^2$, and TP 4.06 mg/$m^2$, which indicates that the COD's runoff load was especially high. The average EMCs from vineyard_A and vineyard_B, which represents the quality of rainfall effluent, were also analyzed: BOD 3.5 mg/L, COD 11.5 mg/L, TOC 5.2 mg/L, SS 211.7 mg/L, TN 1.774 mg/L, and TP 0.324 mg/L. This suggested that the COD, as an indicator of organic pollutants, is high in terms of EMCs as well. As rainfall increased, the EMCs of BOD, COD, TOC and SS kept turning upward. At a point, however, the high rainfall brought about dilution effects and began to push down the EMCs. Higher rainfall intensities led to the increase in the EMCs that displays the convergence of rainfall. Low rainfall intensities also raised pollutant concentrations, although the concentrations themselves were slightly different among pollutants.

강우시 지붕유출수의 EMCs 및 특성비교 (Characteristics of EMCs for Roof Runoff)

  • 홍정선;;;김이형
    • 한국습지학회지
    • /
    • 제14권4호
    • /
    • pp.657-665
    • /
    • 2012
  • 각종 개발사업은 불투수층의 증가를 야기 시켜 자연적 물 순환 왜곡과 함께 비점오염물질의 유출을 증가시킨다. 개발로 인한 환경생태수리학적 영향을 저감하고 건전한 물 순환을 구축하기 위해서는 오염물질의 함량이 적은 유출유량에 대해서는 이용(use)을 고려해 볼 만하며, 오염물질의 함량이 높은 유량에 대해서는 조경공간에서 처리 후 저류, 침투 또는 증발산을 고려하여야 한다. 본 연구는 지붕빗물유출수의 상대적 오염도를 평가하여 이용가능성을 검토하고, 평균 EMC 산정을 위한 비용 효율적 적정 모니터링 기법을 제안하고자 수행되었다. 지붕유출수의 오염도는 도로와 주차장에 비해 오염물질별 3배에서 13배 정도 낮은 것으로 조사되었으며, 나뭇잎, 담배꽁초 등의 협잡물과 바람의 영향으로 인한 오염물질의 대기침적 및 옥상구조물 등이 주요 오염원인 것으로 나타났다. 비용 효율적 모니터링 기법 연구결과 평균 EMC를 보이는 시료는 유출 발생 후 약 15분 경인 것으로 나타났으며, 최소 8회 이상의 강우사상에 대한 모니터링이 수행되어야 평균 EMC를 산정할 수 있는 것으로 나타났다.

강우유출모형을 활용한 교통지역 비점오염원 EMCs 산정 연구 (A Study on the Calculation of Nonpoint Source EMCs using SWMM in Transportation Area)

  • 권헌각;임태효;이재운;정현기;이춘식;천세억
    • 한국습지학회지
    • /
    • 제17권2호
    • /
    • pp.193-202
    • /
    • 2015
  • 본 연구에서는 토지피복 중 교통지역을 대상으로 장기 모니터링된 비점오염원 부하유출 결과를 검 보정 자료로 적용하여 SWMM 모형을 지점별로 구축하였다. SWMM을 통해 모의된 EMCs값의 변동범위는 BOD, $COD_{Mn}$, SS, T-N, T-P 농도가 각각 5.7~14.4 mg/L, 12.9~59.6 mg/L, 13.74~46.20 mg/L, 2.03~5.21 mg/L, 그리고 0.117~0.415 mg/L이었다. 또 이 결과를 현장 실측치와 비교한 결과, 실측치에 대한 모의치 오차(%)가 각각 4.2%, 4.8%, 2.3%, 5.7%, 14.4%으로 총인의 14.4%를 제외하고 오차범위가 10% 이하이었다. 문헌조사 결과와의 비교에서도, BOD, T-P의 경우는 문헌조사 농도변화 범위 내에 포함되었으며, CODMn, SS의 경우 범위보다 낮게 산정되었다. 그러나 T-N의 경우 범위보다 높았다. 이러한 차이는 기존 문헌이 조사된 시기와 토지이용형태가 달라진 최근의 비점오염원 유출 농도를 장기 모니터링하고, 이 결과를 바탕으로 구축, 모의 된 EMCs의 경우 실측값을 잘 대변하였다. 따라서 문헌 결과와의 일부 차이는 조사 시기별 토지이용 형태에 의한 차이로 보이며, 향후 좀 더 다양한 강우사상 및 지점에 대한 모니터링을 통해 국내 대푯값으로 적용할 수 있는 EMCs를 산정할 수 있을 것으로 판단된다.

주차장 및 교량 강우유출수의 중금속 오염물질 특성과 동적 EMCs (Characteristics of Metal Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms)

  • 김이형;이선하
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.385-392
    • /
    • 2005
  • The control of nonpoint source pollution is essentially needed to successfully perform the Total Maximum Daily Load program. Of the various land uses in the nonpoint source, the paved areas such as a parking lot and a bridge are stormwater intensive land uses because of high imperviousness and high pollutant mass emissions. This research was performed to understand the magnitude and nature of the stormwater emissions with the purposes of quantifying stormwater pollutant concentrations and mass emission rates from a parking lot and a bridge. Two monitoring sites in Kongju city were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the data such as rainfall, water quality and runoff flow rates. This paper will summarize the metal concentration changes during the storm duration and metal EMCs to characterize the concentration profiles in a parking lot and a bridge. Also a new concept, dynamic EMC, will be proposed to find the relationship between EMC and first flush effect. It can be used to determine the economical treatment criteria in best management practices.

산림논복합 소유역에서의 비점부하 강우유출 특성 및 EMC 산정 (Characteristics and EMCs of NPS Pollutants Runoff from a Forest-Paddy Composite Watershed)

  • 송인홍;강문성;황순호;송정헌
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.9-17
    • /
    • 2012
  • This study was aimed to characterize non-point source (NPS) pollutant runoff and estimate event mean concentrations (EMCs) from a small rural watershed located at the headwater area of the Gyeongan stream. The study watershed consists of the two major landuse, forest (72 %) and paddy field (28 %). The nine rainfall events ranging from 18.5 to 192.6 mm in amount were monitored in this study. Stream flow was measured at the watershed outlet using a water level gauge, while a number of water samples for each event were collected and analysed for water quality. Event pollutant loads varied greatly depending on rainfall events varying from 22.6 to 3,134.2 mg/L, 0.32 to 24.56 mg/L, 0.090 to 1.320 mg/L, and 2.3 to 149.8 mg/L for SS, TN, TP, and COD, correspondently. The respective mean EMCs were estimated by 104.2, 1.00, 0.168, and 7.9 mg/L. The Pearson correlation analysis showed that COD EMC was significantly correlated with those of SS, TN, and TP. Rainfall runoff ratio appeared to be negatively correlated with EMCs of SS, TP, and COD, although not statistically significant. The event loads from the largest rainfall was greater than the sum of those from the remaining eight events. The study results suggest that the appropriate management of intensified storm events are of greater importance in curbing NPS loads, while the estimated EMCs provide base data for the unit pollutant loads determination for the forest-paddy composite upstream watershed.

주차장 및 교량지역의 강우유출수내 비점오염물질의 특성 비교 및 동적 EMCs (Characteristics of Washed-off Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms)

  • 김이형;이선하
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.248-255
    • /
    • 2005
  • Since the water quality of drinking water sources has been recognized as a big issue, the ministry of Environment in Korea is designing the total maximum daily load (TMDL) program for 4 major large rivers. The TMDL program can be successfully performed as controling the nonpoint pollutants from watershed area near the river. Of the various landuses in nonpoint pollution, parking lots and bridges are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicular activities. Vehicle emissions from those areas include different pollutants such as heavy metals, oil and grease and particulates from sources such as fuels, brake pad and tire wear, etc. Especially the pollutant washed-off from the landuses are directly affecting to the river water quality. Therefore this research was conducted to understand the magnitude and nature of the stormwater emissions with the goal of quantifying stormwater pollutant concentrations and mass emission rates of pollutants from parking lot and bridges in Korea. In Kongju city areas, two monitoring sites were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the useful data such as rainfall, water quality and runoff flow. This manuscripts will show the concentration changes during storm duration and EMCs to characterize the concentration profiles in different land uses. Also the first flush criteria will be suggested using dynamic EMCs. The definition of dynamic EMC is a new approach explaining the relationship of EMC and first flush effect.

논에서 일주기 수질조사시 채수빈도가 오염부하량 산정에 미치는 영향 (Effects of Sampling Frequency During Storm Period on Estimation of Pollutant Load from Paddy Field)

  • 한국헌;윤광식;조진구;조재영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.283-286
    • /
    • 2003
  • In order to examine effects of sampling frequency during rainfall-runoff process from paddy field on the estimation of pollution load, EMCs of several water sampling frequencies were examined. It was found that the difference of EMCs between one time sampling and two hours consecutive sampling during storm event showed $34.1{\sim}-19.1%$ for T-N, $55.4{\sim}-27.3%$ for T-P, $68.5{\sim}-41.0%$ for the SS, respectively. Five times sampling reduced difference of EMCs compared to those two hours interval sampling to $15.2{\sim}-15.2%$ for T-N, $20.0{\sim}-26.2%$ for T-P, $28.6{\sim}-35.7%$ for the SS, respectively.

  • PDF

농지-임야 유역의 비점원 발생 BOD 부하의 추정 (Estimation of BOD Loading of Diffuse Pollution from Agricultural-Forestry Watersheds)

  • 김건하;권세혁
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.617-623
    • /
    • 2005
  • Forestry and agricultural land uses constitute 85% of Korea and these land uses are typically mixed in many watersheds. Biological Oxygen Demand (BOD) concentration is a primary factor for managing water qualities of the water resources in Korea. BOD loadings from diffuse sources, however, not well monitored yet. This study aims to assess BOD loadings from diffuse sources and their affecting factors to conserve quality of water resources. Event Mean Concentration (EMC) of BOD was calculated based on the monitoring data of forty rainfall events at four agricultural-forestry watersheds. Exceedence cumulative probability of BOD EMCs were plotted to show agricultural activities in a watershed impacts on the magnitude of EMCs. Prediction equation for each rainfall event was proposed to estimate BOD EMCs: $EMC_{BOD}(mg/L)=EXP(0.413+0.0000001157{\times}$(discharged runoff volume in $m^3$)+0.018${\times}$(ratio of agricultural land use to total watershed area).

도시, 농촌 및 임야유역으로부터 배출되는 비점원 오염부하의 특성비교 (Comparison of Discharge Characteristics of NPS Pollutant Loads from Urban, Agricultural and Forestry Watersheds)

  • 여중현;김건하
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.184-189
    • /
    • 2005
  • Impacts of non-point source pollution on water quality are well known. In this paper, effects of land use, precipitation characteristics, discharge characteristics on non-point source pollutant loadings at urban, agricultural and forestry watersheds were discussed. Rainfall runoffs from fifteen rainfall events were sampled and analysed at two urban watersheds, one rural watershed, and one forestry watershed. EMCs (Event Mean Concentration) were calculated based on monitored flow rates and concentrations. Statistical analysis carried out with runoff loadings and affecting variables indicated that runoff loadings are weakly correlated with the rainfall intensity and the dry days before rainfall events while showed no correlations with rainfall depth nor runoff quantity. By comparing EMCs between study watersheds on log-normal cumulative probability scale, EMCs ranking were in the descending order of urban watershed>agricultural watershed>forestry watershed for SS, TCOD, TN, and TP.

강우 시 수영강 유역의 수질변화 특성 (Characteristics of Changes in Water Quality in the Suyoung River During Rainfall Event)

  • 김수현;김정선;강임석
    • 한국물환경학회지
    • /
    • 제35권1호
    • /
    • pp.9-18
    • /
    • 2019
  • Recently, it was realized that a significant portion of pollution from urban areas originates from non-point sources such as construction sites, washoff from impervious surfaces, and sewage input from unsewered areas and combined sewer overflows. Especially, Urban stormwater runoff is one of the most extensive cause of the deterioration of the water quality in streams located in urban area. The objective of this study was to investigate runoff characteristics of non-point pollutants source at the urban area in the Suyeong River. Water quality variations were investigated at two points of Suyeong River during a period of 10 rainfall events. Concentration difference of non-point pollution source appeared big by precedent number of days of no rainfall. In addition, Event mean Concentration (EMCs) that well represents runoff characteristics of storm water during rainfall, was calculated, and runoff pollutants loading was also examined. The probability distribution of EMCs of BOD, COD, TOC, T-N, T-P, and TSS were analyzed and the mean values of observed EMC and the median values of estimated EMCs compared through probability distribution. Other objectives of this study were the characterization of discharge from non-point source, the analysis of the pollutant loads and an establishment of a management plan for non-point source of Suyeong River. Also, It was established that the most important thing for the administration of non-point pollution source is to come up with the solution for the reduction of effluent at the beginning.