• 제목/요약/키워드: EI

검색결과 782건 처리시간 0.024초

Emotional Intelligence Profile and Employee Attitude

  • Seoyeon LEE;Jaeseung MOON
    • 동아시아경상학회지
    • /
    • 제11권2호
    • /
    • pp.1-13
    • /
    • 2023
  • Purpose - The purpose of this study is to identify emotional intelligence (EI) profiles according to the sub-factors of the ability EI model, namely, self-emotional appraisal, others' emotional appraisal, regulation of emotion, and use of emotion. In addition, this study aims to reveal whether there is a difference in job satisfaction, affective commitment, and turnover intention depending on the profile. Research design, data, and methodology - For the study, 536 survey responses were analyzed using SPSS 22 and MPlus 8.4. Result - The analysis identified four EI profiles. These were 1) middle-low generalized EI (all sub-factors of EI were slightly lower than the average level), 2) middle-high generalized EI (all sub-factors of EI were slightly higher than the average), 3) low generalized EI (all EI sub-factors were much lower than the average), and 4) high generalized EI (all EI sub-factors were much higher than average). Furthermore, significant differences were found in job satisfaction, affective commitment, and turnover intention according to each profile. Conclusion - This study expands the EI theory by revealing the profile of EI. In addition, this study investigated the impact of EI profile on job satisfaction, affective commitment, and turnover intention.

웹기반의 유량 군집화 EI 평가시스템을 이용한 SWAT 직접유출과 기저유출 평가 (SWAT Direct Runoff and Baseflow Evaluation using Web-based Flow Clustering EI Estimation System)

  • 장원석;문종필;김남원;유동선;금동혁;김익재;문유리;임경재
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.61-72
    • /
    • 2011
  • 유역 단위 수문 및 수질 평가 모형인 SWAT 모형을 이용한 유역 내 정확한 수문과 비점오염원 거동을 평가하기 위해서는 유역 적용에 앞서 모형의 정확성 평가가 우선시 되어야 한다. SWAT 모형의 수문 보정및 검정 시, Nash-Sutcliffe의 효율계수(EI)가 널리 사용되고 있다. 그러나 이러한 EI 값은 비교되어지는 값들의 범위 중 큰 값 즉, 수문 분석에 있어 고유량에 대해 민감하게 영향을 받는 것으로 알려져 있다. 그리하여 본 연구에서는 보다 정확한 수문 분석을 위해 K-means 군집화 알고리즘을 이용한 웹기반의 EI 평가시스템을 개발하였고, 이를 SWAT 모형의 수문 평가에 적용하였다. 본 연구의 결과 전체 유량의 EI 값은 높았지만, 수문성분에 따른 EI 값은 높지 않았다. SWAT 모형의 수문 보정 및 검정에 널리 활용되고 있는 SWAT auto-calibration tool은 전체 유량에 대해서는 높은 EI 값을 산정하는 것으로 보이지만, 직접유출과 기저유출 각각에 대한 유량 그룹 I 과 II 에 대해서는 대부분 음수(-)의 EI 값을 보였다. 그리하여 본 연구 결과를 통해 SWAT 모형의 수문성분 평가에 있어 보다 정확한 평가를 위해서는 직접유출과 기저유출에 대한 각각의 유량 그룹에 대해 양수(+)의 EI 값이 산정되도록 모형 보정 및 검정의 수행 필요할 것으로 사료된다.

EXAMINATION OF CALCULATION METHOD FOR THE FLEXURAL RIGIDITY OF CROP STALKS

  • Hirai, Yasumaru;Inoue, Eiji;Hashiguchi, Koichi;Kim, Young-Keun;Inaba, Shigeki;Tashiro, Katsumi
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.287-294
    • /
    • 2000
  • Calculation of the flexural rigidity value (EI) is indispensable for prescription of deflection characteristics of crop stalks in harvesting□Conventionally□EI has been determined by either average EI of the whole stalk or average EI of each stems divided into node through the calculation method of cantilever with homogeneous section□However□deflection characteristics of crop stalks caused by mechanical operation such as combine harvester were not exactly presumed by these conventional EI through the experiment by authors. Further, actual EI of a stalk changes in company with a change of moisture contents as time passes during the experiment. Finally, efficient calculation method for determining EI is needed in order to improve these problems. In this study, mechanical model based on actual structure of the crop stalk with variety sectional area was proposed. This mechanical model is calculated by the theory of cantilever with continuous stages. Therefore, improvement of both calculating accuracy on EI and efficiency of measuring system was tried. At first, this calculation method was applied to piano wire of which EI was recognized in advance. As a result, EI calculated from this new method coincided approximately with piano wire's EI. Next, applying to crop stalks as same as piano wire, relationship between loads acting on crop stalks and deflection values calculated by EI using this new calculation method was exactly presumed in comparison with conventional method. Further, measuring time of deflection test was greatly reduced. Finally, new calculation method of EI will be available for estimating mechanical characteristics of so many kinds of crop stalks in harvesting operation. Further, in this study, new deflection test using image-processing apparatus by computer will be introduced.

  • PDF

진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구 (A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level)

  • 박혜민;윤용수;김은혜;정회원;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구 (The Review of Exposure Index in Digital Radiography and Image Quality)

  • 양숙;한재복;최남길;이성길
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.29-36
    • /
    • 2013
  • CR과 DR 장비에서 팬텀을 이용하여 선량과 노출지수(exposure index, EI)의 변화를 관찰하고 처리된 영상에서 NSR(noise to signal ratio)과 CNR (contrast to noise ratio)을 측정하여 디지털 시스템에서 방사선량을 최적화하기 위한 인자들 간의 상관관계를 알아보고자 하였다. EI와 입사표면선량(entrance surface dose, ESD)는 CR과 DR 장비에서 모두 주어진 선량의 증가에 따라 비례하여 증가하였다. 적정범위 내 EI 산출시 CR의 경우 DR 보다 더 많은 선량이 요구되었으나 두 시스템에서 모두 EI 지표는 노출인자인 kVp, mAs의 증가에 대해 선형으로 비례하여 증가하였다. 특히, 검출기 효율이 우수한 DR 시스템에서는 선량 변화에 대해 더 안정된 감도를 나타내었고, 최소의 선량증가에도 영상의 유용한 대조도를 형성하여 화질의 향상에 쉽게 도달할 수 있었다. 이는 검출기 흡수선량과 밀접한 관련이 있는 EI 지표의 정확성을 예측 가능하게 하였다. EI의 물리적 특징과 영상평가를 위한 NSR 측정은 DR 시스템에서 CR 보다 더 낮은 NSR이 나타났으며 CR에서는 6 mAs이상의 관전류에서는 관전압의 값에 따른 영향이 상대적으로 적었다. 본 연구 결론은 디지털 시스템 검출기의 흡수선량 측정의 지표인 EI는 노출인자와 선형비례관계에 있었고 EI가 제조사에서 제공한 범위 내에 존재할 때 그 EI 지표가 우수할수록 최적의 영상화질을 얻을 수 있었다. 또한 디지털 방사선 영상 기술에서 EI의 물리적 특징의 활용은 실제 임상에서 영상의 화질향상에 도움을 주고 검출기의 품질관리를 통하여 환자의 불필요한 피폭선량을 줄이는 데 많은 기여를 할 수 있을 것이다.

The Impact of Emotional Intelligence on Performance: A Closer Look at Individual and Environmental Factors

  • NGUYEN, Khai The;DUONG, Tuyet Minh;TRAN, Nhi Yen;HA, Anh Thao;PHUNG, Y. Nhu Thi
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권1호
    • /
    • pp.183-193
    • /
    • 2020
  • This study presents a more comprehensive approach to investigate how Emotional Intelligence (EI) is associated with performance. Previous research has revealed that EI is related to positive outcomes such as better performance, life satisfaction and career success. However, in most research of EI, this factor has been investigated independently from the effect of contextual factors and other individual characteristics. This study extended the research on the impact of EI on student performance by simultaneously examining the impact of EI, individual factors - (1) Perseverance of Effort, (2) Goal Consistency and (3) Goal Clarity and learning environment factors - Program Fit in one study. The results based on the data collected from 1,117 students in Vietnam largely support the hypothesis that that EI was an important but not the only factor affecting the student performance. MANOVA and post-hoc analysis indicated that both individual and environmental factors better predicted performance than EI could. These results suggest that the impact of EI on individual performance is more complicated than what we have already known. Future study is encouraged to investigate both the mechanism through which EI impact individual performance and the interaction between EI and other factors that moderate the EI - performance relationship.

Photocatalytic degradation of organic compounds by 2-ethylimidazole-treated titania under visible light illumination

  • Seo, Jiwon;Jeong, Junyoung;Lee, Changha
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.223-229
    • /
    • 2019
  • Titania modified by 2-ethylimidazole (2-EI) (denoted as $2-EI-TiO_2$) demonstrated visible light photocatalytic activity for the degradation of organic compounds. $2-EI-TiO_2$ was a bright brown powder that exhibited similar crystallinity and morphology with the control $TiO_2$. A diffuse reflectance spectrum indicated that $2-EI-TiO_2$ absorbs visible light of all wavelengths. X-ray photoelectron spectroscopy (XPS) confirmed the cationic state of nitrogen species (e.g. Ti-O-N) on the surface of $2-EI-TiO_2$. Visible light-illuminated $2-EI-TiO_2$ degraded $10{\mu}M$ 4-chlorophenol (4-CP) by approximately 85% in 4 h. The photochemical activity of $2-EI-TiO_2$ was selective in targeting the organic compound. The repeated use of $2-EI-TiO_2$ decreased the photocatalytic activity for the 4-CP degradation. Experiments using radical scavengers and oxidant probes revealed that the oxidation by photogenerated holes is responsible for the degradation of organic compounds by illuminated $2-EI-TiO_2$ and the role of $^{\bullet}OH$ is negligible.

서비스 직원의 감성지능이 서비스지향 조직시민행동에 미치는 영향: 내면연기의 매개효과성 (The Effect of Service Employees'Emotional Intelligence on Service-Oriented OCB through Deep Acting)

  • 양은연;안희규;신호철
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.659-676
    • /
    • 2018
  • Purpose: Although emotional intelligence(EI) is seemingly related to the service-oriented citizenship behaviors(OCB) of contact employees who are directly interacting with customers, there are only a few studies examining the relationship between the two. This study attempts to provide empirical evidence for a link between EI and service-oriented OCB. In addition, when EI affects service-oriented OCB, this present study identifies which emotional labor strategy between surface acting and deep acting is to be chosen. Methods: The data of EI, service-oriented OCB, surface acting, and deep acting were collected from 142 sales employees who provided services in four large domestic department stores. Hierarchical regression analyses were performed to verify empirically the main effects between EI and service-oriented OCB and mediating effects of emotional labor strategy. Results: The results show that EI is significantly related to service-oriented OCB in the current sample. Results also indicate that the deep acting rather than surface acting reveals a mediating effect in the process of EI affecting service-oriented OCB. Conclusion: The results of this study shows that EI which has a conceptual basis for OCB, can be extended to service-oriented OCB, The results also contribute to expanding the understanding of the relationship between EI and service-oriented OCB by testing the effect of EI on service-oriented OCB through deep acting. Theoretical and practical implications are reviewed, and limitations of the study and suggestions for future research are addressed.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

돌연변이 유기에 의한 대두 품종개량연구 -I. 대두에 대한 EMS, EI 및 ${\gamma}$선처리효과비교(예보) (Studies of Soybean Improvement by ${\gamma}$-ray and Chemical Mutagens -I. Comparison of the effects of EMS, Ei, and ${\gamma}$-rays in soybean(preliminary report))

  • 권신한;임건혁;손청열;은종선
    • 한국작물학회지
    • /
    • 제7권1호
    • /
    • pp.139-144
    • /
    • 1969
  • 본실험은 대두품종 장단백일과 Clark의 건조종자에 ${\gamma}$선, EMS, EI, 및 ${\gamma}$선과 화학약품과의 조합처리로써 조열, 내도복, 고단백, 다수성 등 유용한 돌연변이계통을 선발할 목적으로 수행하였는데 기초자료로써 처리상대의 돌연변이유기물에 대한 감수성을 조사하였다. 1. ${\gamma}$선의 조사는 장단백일에서 선량증가에 따라 발아 및 생잔율에 큰 장해를 주었으나 Clark에서는 일정한 경향을 찾아 볼 수 없었다. EH한 초장에 있어서는 양 품종 모두 선량이 증가 할수록 고도의 유의성이 있는 생장장해를 보였다. 2. Chemical mutagens을 처리한 경우는 양 품종 똑같이 Ei의 농도가 증가함에 유의성있게 발아율이 감소되었으며 특히 EI의 0.003 Mol. 농도에선 아주 극심한 장해를 나타내고 있다. EMS처리는 발아와 생잔율에 유의성있는 변화를 주지 못했으나 초장에서 장단백일은 농도가 증가함에 따라 유의적인 생육장해가 나타났다. Clark에선 일정한 경향을 찾아 볼 수 없었다. 3. ${\gamma}$선 24KR과 FMS 각 농도를 조합처리한 것은 EMS 단독처리 보다 유의하게 발아율이 떨어졌으며 EI과의 조합처리구에서는 ${\gamma}$선 24KR+EI 0.002 Mol을 제외한 각조합처리의 발아율은 EI 단독처리보다 오히려 양호한 결과를 나타냈다. 생잔율에서는 뚜렷한 경향을 찾지 못하였으나 초장에선 ${\gamma}$-선 24KR+EMS 각 농도조합과 그 단독처리구를 비교할 때, 양 품종 모두 고도의 유의차로 조합처리가 생육장해정도를 크게 나타냈다. EI와 ${\gamma}$-선 조합처리가 저농도에서는 초장의 감소를 나타냈으나 ${\gamma}$-선24KR+EI 0.008Mol. 처리구에선 장단백일의 파종후 21일만 제외하고 단독처리구 보다 초장이 증가하는 경향이 나타났다. 4. 일반적으로 본 실험에선 발아율과 생잔율이 EMS 단독 및 ${\gamma}$-선+EMS 처리구에서 양호한 결과를 보았으며 EI 및 ${\gamma}$-선+EI 처리구에선 그 고농도구에서 발아율을 감소시켰으나 초장에 나타나는 생육장해는 적었고 오히려 촉진되는 경향도 있었다. 5. 발아율, 생잔율 및 초장을 기준으로 한 감수성을 비교해 보건데 대체적으로 장단백일은 Clark에 비해 매감하였으며 이는 그 감수성이 유전인자구성에 따라 크게 차이를 줄 수 있다는 것을 입증하고 있다.

  • PDF