Parameter Selection of the Saturable Reactor for Removing Ferroresonance of 362kV Gas VT Using EMTP (EMTP를 이용한 362kV Gas VT의 철공진제거를 위한 가포화리엑터의 파라미터 선정)

  • Choi, Jae-Gu;Kim, Ik-Soo;Park, Kyoung-Won;Song, Hee-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • Recently, the construction of gas insulated substation(GIS)s has been increased in Korea. But, the whole quantity of the VTs which were used in GIS has been imported. Under the circumstance that $SF_6$ gas power apparatus are being developed up to 800kV rating in Korea, the development of EHV $SF_6$ gas VT is essential for localizing the power apparatus. As for EHV VT, destructive ferroresonance can be generated due to the combination of capacitiances between poles of circuit breaker, ground capacitance of bus and nonlinear excitation property of VT core. But the theoretical analysis about ferroresonance has not been fully achieved in Korea. Therefore, in this paper the authors would like to contribute for localizing EHV $SF_6$ gas VT by developing the diagram of ferroresonance zone according to the parameters of the circuit and the saturable reactor.

  • PDF

The Effect of Swelling Rate for 400kV PPLP Insulated Oil-Filled Electric Power Cable (400kV급 반합성지 전력케이블용 절연지(PPLP)의 팽윤현상이 전기적 성능에 미치는 영향)

  • Park, Se-Eun;Lee, Sang-Jin;Kim, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1363-1363
    • /
    • 2006
  • PPLP를 절연지로 사용하는 OF 케이블 절연지의 팽윤 특성은 전력 케이블 절연특성에 크게 영향을 줄 뿐만 아니라, 케이블 제조나 운전시에도 영향을 미치므로 매우 중요한 설계 관리 요소이다. 특히 PPLP 케이블 제조시 PPLP의 팽윤 정도에 따라 지권장력의 설정이 달라지므로 반드시 고려해야만 한다. 기존의 일반적인 Kraft지를 절연지로 사용하는 OF 케이블의 경우는 팽윤 현상이 거의 없어 지권장력 설정시 이를 고려하지 않아도 되지만, PPLP는 이를 고려하지 않고 지권을 찬다면 케이블 제조 후 절연지의 끊어짐 현상, 절연층의 butt-gap 현상 둥 Polypropylene laminated paper를 절연지로 사용하는 케이블의 경우, 팽윤 현상의 발생으로 인해 절연파괴가 일어날 수 있다. 그러나 PPLP 절연지를 사용하는 이유는 케이블의 장거리 운전시 기존 Kraft지를 사용했을 때 보다 유전손실이 더 개선될 뿐만 아니라 절연체의 두께를 저감하여 포설이 용이하기 때문이다. 이에 본 논문에서는 PPLP에서 고분자의 팽윤이 일어나는 정도에 따라 결정화도의 변화와 전기적인 성능(체적저항, AC 파괴)과의 연관성을 검토하였다.

  • PDF

A Study on the Electric Field Analysis of EHV Overhead Distribution Lines Using Maxwell 3D - I (Maxwell 3D를 이용한 특고압 배전선로의 전계해석에 관한 연구 - I)

  • Seo, Y.P.;Park, S.W.;Kim, C.H.;Won, C.Y.;Nam, K.D.;Ha, S.N.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.847-849
    • /
    • 1996
  • As the power demands increases, one of the most important data is inside electric field of equipment in designing of insulators ami insulated wire for EHV distribution line. So far finite element analysis method is widely used to calculate this electric field. However as the shape of insulator becomes complicated, it is difficult in producing the mesh which suitable the shape. Especially, we have many difficulty that produce dense fine mesh only where the electric field is concentrated. Therefore in this paper, we perform the each conditional analysis of electric field using the Maxwell 3D Simulator to recover this defects. And we try to analyze electric field through the conventional 2 dimensional and 3 dimensional analysis in case of salt contamination on the surface of a insulator.

  • PDF

Estimation of Fault Location on Transmission Lines using Current Phasor (전류 페이저를 이용한 송전선로 고장점 추정 알고리즘)

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2095-2100
    • /
    • 2009
  • Since most of the Extra High Voltage (EHV) transmission lines are untransposed and multi-circuits, errors are occurred inevitably because of the unbalanced impedances of the lines and so on. Therefore, a distance relaying algorithm applicable to the untransposed multi-circuits transmission lines needs to be developed. The proposed algorithm of fault location estimation in the paper uses the fundamental phasor to reduce the effects of the harmonics. This algorithm also analyzes the second-order difference of the phasor to calculate the traveling times of waves generated by faults. The traveling time of the waves generated by faults is derived from the second-order difference of the phasor. Finally, the distance from the relaying point to the faults is estimated using the traveling times. To analyze the performance of the algorithm, a power system with the EHV untransposed double-circuit transmission lines are modeled and simulated under various fault conditions such as several fault types, fault locations, fault inception angles and fault resistances. The results of the simulations show that the proposed algorithm has the capability to estimate the fault locations quickly and accurately.

Electric Field Distribution according to Gradient of Electrode in EHV Insulators of XLPE (침전극 기울기에 따른 초고압 절연체 XLPE의 전계분포)

  • Ahn, B.C.;Park, H.D.;Byeon, D.G.;Lee, J.P.;Kim, G.Y.;Ryu, B.H.;Chae, H.I.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.79-80
    • /
    • 2006
  • 본 논문에서는 초고압전력용 케이블에서 절연재료로 사용되고 있는 가교폴리에틸렌 내부(XLPE)에 침투된 침전극의 기울기변화에 따른 XLPE의 전계분포를 경계요소법에 의한 3차원 시뮬레이션 프로그램을 통하여 해석하여, 약 $20^{\circ}$의 기울기에서 전계가 집중되는 현상을 확인하였다.

  • PDF

CIGRE

  • 구자윤
    • 전기의세계
    • /
    • v.36 no.8
    • /
    • pp.582-588
    • /
    • 1987
  • 20세기에 들어와 전력수요가 증가함에 따라 송전전압의 상승이 요구되어 EHV 송전계통의 설치가 시급하게 되었고 아울러 고전압 기술이 급속도로 성장함에 따라, 전문가들이 서로 모여서 발생되는 문제점과 엔지니어링 경험을 서로 교환해야할 필요성이 요구되어 1921년에 CIGRE가 창설되었다. CIGRE는 현재 약70여개의 참가회원국을 갖고 있으며, 국내위원회를 조직하여 적극적으로 활동하고 있는 나라는 45개국에 이르고 있다. 우리나라에서는 중전기 분야의 산업체가 성장함에 따라 1980년에 CIGRE국내위원회가 조직되었다. 먼저 CIGRE의 성격과 기능에 대해 설명을 한뒤, 한국 국내 위원회의 발전사항에 대해서도 간략하게 기술하였다.

  • PDF

A Comparison for High-Speed Redosing on EHV System (초고압송전계통에 적용할 고속도재폐로방식의 비교검토)

  • 이주희
    • 전기의세계
    • /
    • v.20 no.6
    • /
    • pp.29-36
    • /
    • 1971
  • 초고압송전계통의 주요 사양중에서 특히 고속도재폐로방식은, 선로개패이상전압의 크기에 관련되는 차단기의 사양과 계통신뢰도를 결정하는 보호계전장치의 주요한 결정요소가 된다. 따라서 가장 합리적인 개폐로방식을 선택할려면 계통발전의 초기상태에서 부터 최종 단계의 계통규모와 계통운용기준을 충분히 검토하여야 한다. 본 고에서는 초고압계통에 적용되는 최근의 재폐로방식 경향과 우리가 발전시키려는 계통규모에 적합한 재폐로방식을 비교검토한다.

  • PDF

The KECO'S 345KV EHV Project : the History and Its Prospect (초고압설비계획의 경위 및 전망)

  • 이봉용
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.35-41
    • /
    • 1973
  • 송전전압은 계속 높아지고 있어 800KV 교류송전 또는 1500KV(.+-.750KV) 직류송전까지에 이르고 있다. 우리나라에서도 금년중에 345KV 초고압설비의 착공을 예정하고 있으며 1976년까지에는 그 일단계규모를 완성시킬 계획이다. 이와같은 위라나라 최초의 초고압설비의 설현을 앞에두고, 그동안의 경위를 돌아보고 앞으로의 전망을 살펴보는것이 또한 뜻있는 일로 생각되어, 이하 초고압설비의 필요성, 특성, 경위 및 금후의 전망이라는 순으로 요약 기술코저 한다.

  • PDF

Estimate of Insulation thickness for EHV XLPE power cable (345kV CV케이블의 절연두께 산정)

  • Choi, Bong-Nam;Yun, Duck-hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1801-1803
    • /
    • 2001
  • At present the under ground power transmission systems have installed until 154KV XLPE power cable in Korea But, the large capacity underground power transmission systems have been required gradually with the increasing demand of electric power. Therefore, our company has developed 345KV XLPE cable. This paper describes the estimate details of the insulation thickness according to weibull plotting for 345KV XLPE power cable.

  • PDF

The study on the Long-Term overvoltage test of EHV Gas Voltage Transformer (초고압 GAS Voltage Transformer의 장기 과전압 시험에 관한 연구)

  • Song, H.S.;Park, K.W.;Keu, G.S.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.157-159
    • /
    • 2002
  • In order to obtain reliability and extend life of GAS Voltage Transformer in GIS, it has to prevent aging by overvoltage considered to insulation characteristics of insulating material. This paper describes some characteristics of V-T characteristics and partial discharges.

  • PDF