• 제목/요약/키워드: EHV

검색결과 154건 처리시간 0.025초

유한요소법에 의한 초고압 OF 케이블 접속재의 주도해석에 관한 연구 (Study on the Thermal Analysis of Extra-High Voltage OF Cable Accessories using Finite Element Method)

  • 이종범;강동식;강도현;이수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.211-215
    • /
    • 1989
  • This paper presents the thermal analysis of EHV OF cable accessories using FEM. The governing equation about the temperature in the cable accessories is induced by the energy balance equation. Since the temperature distribution is a function of space and time, the weighted residual method is adopted for FEM formulation. The difference approximation is used to treat the time differential term in the element equation. Automatic mesh generation which save time and labor is introduced for the data input process. It will be expected that the following thermal analysis result will be very useful to cable accessories design.

  • PDF

보상 알고리즘을 이용한 초고압 계통의 모선보호용 비율 전류차동 계전방식에 관한 연구 (A Study on a Percentage Current Differential Relaying Algorithm for EHV Bus Protection Using a Compensating Algorithm)

  • 강용철;윤재성;김동용;박종근;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1139-1141
    • /
    • 1999
  • A variable percentage current differential relaying algorithm is widely used for bus protection. However, it may maloperate in case of high-impedance internal faults and external faults with CT saturation and thus additional method to cope with CT saturation is necessary. This paper proposes a percentage current differential relaying algorithm for bus protection using a compensating algorithm of secondary current of CTs. As the proposed method compensates the distorted secondary currents of CTs it can improves the sensitivity of relays in a large current region and does not need any additional method for CT saturation.

  • PDF

The Lightning Current Parameters that Impact on the Surge Analysis of the EHV Gas Insulated Substation by EMTP

  • Shim Eung-Bo;Han Sang-Ok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권1호
    • /
    • pp.1-7
    • /
    • 2005
  • This paper describes the lightning surge analysis model of extra high voltage GIS using EMTP. Various lightning current parameters were investigated in order to confirm the impact on the lightning surge analysis such as lightning current amplitude, waveform, size of GIS, tower footing resistance and surge arresters. The multi-story tower model and EMTP/TACS model were introduced for the simulation of dynamic arc characteristics. The margin between the maximum overvoltage and BIL of the GIS was about 10 percent and the margin between the maximum overvoltage and BIL of the transformer was 21 percent.

장조장 XLPE 케이블 절연 파괴 원인 규명을 위한 전구차단 장치의 응용 (The Application of Pre-Breakdown Partial Discharge Detection Method for Breakdown of Investigation of Long Distance XLPE Cable)

  • 이창영;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1827-1829
    • /
    • 2002
  • This paper describes AC test for long delivered drum length of cable using pre-breakdown partial discharge detection(PPD) method, which can be applied to observe the causes of electrical breakdown of EHV XLPE insulation. This method is to de-energize applied voltage to cable rapidly using pre-breakdown partial discharge, and is able to prevent complete breakdown. By this effect, defects such as voids, metal particles and protrusion in cable can be observed clearly. AC resonant test set was used for PPD method. Localization of partial discharge was performed by time difference detection of the traveling wave. Accuracy of localization was 1% to the length of test cable. Through several experiments with XLPE cable, successful results of PPD method were obtained.

  • PDF

초고압 고내력 케이블 국내 최초 현장 적용 (First Installation of High Stress EHV XLPE Cable in korea)

  • 오종옥;조성훈;이상교;김한중;오동수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

박전극을 이용한 고주파 부분방전 측정 연구 (High frequency partial discharge measurement by metal foil electrode)

  • 김충식;신두성;이창영;김정년;백주흠;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1081-1083
    • /
    • 1999
  • The capacitive coupling technique has been used as conventional method for PD detection on the power cable line. Recently, however PD measurement using by high frequency is known to have an excellent sensitivity comparison with low frequency on-site. In this paper, the high frequency characteristic of two type of metal foil sensor was studied and the technique was proved to be more effective diagnostic method than conventional method for qualification of EHV cable and accessories.

  • PDF

Recurrence of equine coital exanthema in thoroughbred stallions

  • Yang, Jaehyuk;Lim, Yoon-Kyu
    • 대한수의학회지
    • /
    • 제53권3호
    • /
    • pp.175-176
    • /
    • 2013
  • The object of this study was to evaluate recurrence of equine coital exanthema (ECE) whether re-infection or re-activation of causative virus. ECE is a venereal disease of horses caused by equine herpesvirus type 3 (EHV-3). Like other herpesviruses, it may persist in infected horses for a long time. There is a controversy on the cause of ECE as the recurrence or the reinfection. This disease had occurred firstly on stallions and broodmares in Korea. The horses had rebreeded after healing routinely. Next year, the disease recurrented on the just same affected horses among stallions. The result of this study, re-outbreak of ECE in stallions is recurrence of ECE, but not reinfection of the virus.

정확한 상정사고 분석을 위한 민감도 행렬의 신속한 Update 기법에 관한 연구 (A Fast Sensitivity Matrix Update Technique for Accurate Contingency Analysis State Computation Technique in Power Systems)

  • 이승철;김경신;권병국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.327-329
    • /
    • 2001
  • This paper presents a fast and accurate contingency analysis in EHV systems for line outages, loss of generation of redispatching and loss-of-load or load management. Unlike other contingencies, line outage requires the modification of the Jacobian of the base case power flow and the calculation of its new inverse, which is substantially different from the original inverse. In this paper, we obtain the inverse of the new Jacobian from the original inverse without repeating the time consuming matrix inversion process. Numerical test results show the significant improvement in the accuracies compared with those obtained using the original inverse.

  • PDF

대칭분 전압을 이용한 송전선로 보호용 고장상 선택 알고리즘 (Phase Selection Algorithm using Sequence Voltages for Transmission Line Protection)

  • 이명수;김수남;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.124-126
    • /
    • 2001
  • A reliable fault type identification (phase selection) plays a very important role in transmission line protection, particularly in Extra High Voltage(EHV) networks. The conventional fault type identification algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and identify the fault type in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can identify the accurately fault type using the sum of unit vectors which are calculated by positive-sequence votage and negative-sequence voltage.

  • PDF

대칭분 전류를 이용한 송전선로 보호용 고장상 선택 알고리즘 (Phase Selection Algorithm Symmetrical Components for Transmission Line Protection)

  • 이승재;이명수;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.22-24
    • /
    • 2001
  • This paper presents a fault phase selection algorithm for transmission line protection by means of the symmetrical components. Accurate fault phase selection is necessary for collect functioning of transmission line relaying, particularly in Extra High Voltage (EHV) networks. The conventional phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to abstract only fault current since we can not know the time which a fault occurs. The proposed algorithm can select the accurately fault phase using fault current contained pre-fault current.

  • PDF