EGS4 simulation을 이용한 2차원 방사선준위 분포측정 시스템의 Response Matrix 계산 (The Calculation of Response Matrix of 2-Dimensional Radiation Monitoring System Using EGS4 Simulation)

  • 김성환;한상효;강희동;김재철;박인규;최영수;이용범;이종민
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.127-133
    • /
    • 1997
  • 2차원 방사선 측정시스템에서 측정된 감마선의 에너지 스펙트럼으로부터 실제 에너지 스펙트럼을 얻기 위하여 CsI(T1) 섬광계수기에 대한 EGS4 모의실험을 실시하였다. $0.1{\sim}2$ MeV의 감마선에 대하여 50 keV 간격으로 모의실험을 실시하여 $39{\times}39$ response matrix를 계산하였고 이에 대한 역행렬을 구하였다. 이를 이용하여 실제 측정된 Co-60 에너지 스펙트럼에 대하여 unfolding을 실시하였다. 그 결과 계산된 response matrix가 실제 스펙트럼 분석에 유용한 것으로 판단되었다.

  • PDF

A Study on the Spatial Resolution of Gas Detectors Based on EGS4 Calculations

  • Moon, B.S.;Han, S.H.;Kim, Y.K.;Chung, C.E.
    • Journal of Radiation Protection and Research
    • /
    • 제29권1호
    • /
    • pp.25-31
    • /
    • 2004
  • Results of EGS4 based calculations to study the spatial resolution of gas detectors are described. The calculations include radial distribution of electrons generated by photons of various energies penetrating into variable thickness of Ar and Xe gas layers. Given a desired spatial resolution, the maximum allowed thickness of gas layer for each energy level is determined. In order to obtain 0.1mm spatial resolution, the maximum thickness for the Ar gas is found to be 2mm for photon energies below 14keV while the optimum energy of photons for Xe gas with the same thickness is about 45keV. The results of calculations performed to compare the number of electrons generated by CsI coated micro-channel plate and the number of electrons generated by the Ar and Xe gas layers are described. The results show that the number of electrons generated by the gases is about 10 times higher than the one generated by CsI coated micro-channel plate. A few sample gray scale images generated by these calculations are included.

측정된 원통형 전리함 반응함수의 몬테카를로 시뮬레이션 보정 (The ionization chamber response function from the measured and the corrected by Monte Carlo simulation.)

  • 이병용;김미화;조병철;나상균;김종훈;최은경;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.9-17
    • /
    • 1996
  • 방사선 측정기로 사용되는 원통형 전리함의 위치별 반응 함수를 좁은 방사선장에서 측정하였다. 광자선 에너지 4MV, 6MV, 15MV, 전리함 내경 0.5cm~3.05cm 인 전리함들에 대하여 방사선면의 크기를 0.2$\times$20$\textrm{cm}^2$로 하여 물속 10cm 깊이에서 전리함 반응함수를 측정하였다. 좁은 방사선면의 선량분포 profile 을 EGS4(Electron Gamma Shower 4) 몬테카를로 시뮬레이션 코드를 이용하여 계산하였고, 이 결과를 측정된 전리함의 반응 함수 값에서 되겹말림 (deconvolution) 기법으로 제거하여 순수하게 $\delta$함수 모양의 방사선장으로부터 측정된 반응함수로 보정하였다. 전리함 반응함수는 보정전에는 에너지에 따라 다르게 나타났으나 EGS4 계산으로 얻어진 선량분포 프로파일 (profile)을 보정한 결과 전리함 반응 함수는 에너지와 무관한 것으로 나타났다.

  • PDF

6 MeV 전자선의 측정과 모의계산에 대한 연구 (A Study on the Simulation and the Measurement of 6 MeV electron Beam)

  • 이성아;이정옥;문성록;원종진;강정구;김승곤
    • Radiation Oncology Journal
    • /
    • 제13권3호
    • /
    • pp.285-289
    • /
    • 1995
  • 목적 : 6 MeV의 전자선에 대하여 Monte-Carlo기법을 이용한 모의계산(simulation)과 측정을 함으로써 측정값과 계산값을 서로 비교하고, 이러한 모의계산이 측정을 대신할 수 있을 만큼의 정확도가 있는지를 확인하고자 하였다. 방법 : 선형가속기에서 출력되는 전자선의 심부량 백분율(percent depth dose)을 물팬톰에서 반도체 검출기를 이용하여 조사야 $50{\times}50,\;100{\times}100,\;150{\times}150,\;200{\times}200\;mm^2$에 대하여 측정하였다. 전자선에 대한 선량을 결정하기 위한 모의계산은 EGS4 프로그램을 사용하였다. 결과 : 측정값과 계산값은 유사한 형태로 나타났는데 $100{\times}100\;mm^2$ 조사야 에서 선축상최대선량은 측정값과 계산값이 각각 14mm 와 15mm, 표면선량율은 각각 $76.94\%$$65.52\%$였다. 모의계산에서 표면선량율의 조사야에 따른 변화는 $64.43\%-66.99\%$이고 선축상최대선량은 15mm-18mm 였다. 결론 : 모의계산을 한 결과, 계산값이 측정값과 비교적 잘 일치한다는 것을 알았다. 표면선량율의 차이만을 제거하고 결과를 살펴보면 선축상 최대치등 방사선 치료에 주로 이용되는 부츤의 선량율에서는 모의계산이 측정을 대신할 수 있을 만큼의 정확도가 있다는 것을 확인하였다.

  • PDF

6MV Photon Beam Commissioning in Varian 2300C/D with BEAM/EGS4 Monte Carlo Code

  • Kim, Sangroh;Jason W. Sohn;Cho, Byung-Chul;Suh, Tae-Suk;Choe, Bo-Yong;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.113-115
    • /
    • 2002
  • The Monte Carlo simulation method is a numerical solution to a problem that models objects interacting with other objects or their environment based upon simple object-object or object-environment relationships. In spite of its great accuracy, It was turned away because of long calculation time to simulate a model. But, it is used to simulate a linear accelerator frequently with the advance of computer technology. To simulate linear accelerator in Monte Carlo simulations, there are many parameters needed to input to Monte Carlo code. These data can be supported by a linear accelerator manufacturer. Although the model of a linear accelerator is the same, a different characteristic property can be found. Thus, we performed a commissioning process of 6MV photon beam in Varian 2300C/D model with BEAM/EGS4 Monte Carlo code. The head geometry data were put into BEAM/EGS4 data. The mean energy and energy spread of the electron beam incident on the target were varied to match Monte Carlo simulations to measurements. TLDs (thermoluminescent dosimeter) and radiochromic films were employed to measure the absorbed dose in a water phantom. Beam profile was obtained in 40cm${\times}$40cm field size and Depth dose was in 10cm${\times}$10cm. At first, we compared the depth dose between measurements and Monte Carlo simulations varying the mean energy of an incident electron beam. Then, we compared the beam profile with adjusting the beam radius of the incident electron beam in Monte Carlo simulation. The results were found that the optimal mean energy was 6MV and beam radius of 0.1mm was well matched to measurements.

  • PDF

A Class of Check Matrices Constructed from Euclidean Geometry and Their Application to Quantum LDPC Codes

  • Dong, Cao;Yaoliang, Song
    • Journal of Communications and Networks
    • /
    • 제15권1호
    • /
    • pp.71-76
    • /
    • 2013
  • A new class of quantum low-density parity-check (LDPC) codes whose parity-check matrices are dual-containing matrices constructed based on lines of Euclidean geometries (EGs) is presented. The parity-check matrices of our quantum codes contain one and only one 4-cycle in every two rows and have better distance properties. However, the classical parity-check matrix constructed from EGs does not satisfy the condition of dual-containing. In some parameter conditions, parts of the rows in the matrix maybe have not any nonzero element in common. Notably, we propose four families of fascinating structure according to changes in all the parameters, and the parity-check matrices are adopted to satisfy the requirement of dual-containing. Series of matrix properties are proved. Construction methods of the parity-check matrices with dual-containing property are given. The simulation results show that the quantum LDPC codes constructed by this method perform very well over the depolarizing channel when decoded with iterative decoding based on the sum-product algorithm. Also, the quantum codes constructed in this paper outperform other quantum codes based on EGs.

근접 방사선치료용 이리듐 선원의 선량분포에 대한 몬데칼로 시뮬레이션 (Monte Carlo Simulation for Dose Distributions from Ir-192 in Brachytherapy)

  • 김승곤;강정구;이정옥;정동혁;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.187-194
    • /
    • 2002
  • 본 연구에서는 근접 방사선치료용 Ir-192 선윈의 흡수선량에 관한 물리적 특성들을 몬테칼로 계산을 이용하여 조사하였다. 몬테칼로 계산은 EGS4 코드로 수행하였으며 이를 위하여 원통형 선원과 팬텀 그리고 에너지 분포의 입력과 처리가 가능한 사용자 코드를 작성하였다. 베타선에 대한 계산 결과, 베타선들은 선원과 0.5-5.0 cm 거리에서 전체 흡수선량에 평균 0.02% 기여하는 것으로 나타났다. 이것은 초기 베타선들이 선원과 밀봉물질에서 대부분 흡수를 당하지만 이 과정에서 발생한 저에너지 제동복사 광자들이 원거리까지 기여하기 때문이다. 밀봉물질에 의한 흡수선량의 변화는 백금으로 취한 경우에 평균 2.8% 그리고 철로 취한 경우에 평균 1.1% 감소하는 것으로 나타났다. 몬테칼로 계산으로 구한 반경선량함수는 선원과 0.5-10.0 cm 반경거리 구간에 대하여 TG-43 보고서의 값들과 $\pm$3% 이내로 일치하였다. 본 연구에서 작성한 사용자 코드는 다른 종류 및 다른 크기의 선원에 대해서도 계산을 수행할 수 있어서 근접 방사선치료용 선원의 생산 및 가공에 관한 연구에 다양하게 이용될 수 있다.

  • PDF

GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법 (Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example)

  • 김병용;김형동;김성진;오세안;강정구;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제22권2호
    • /
    • pp.79-84
    • /
    • 2011
  • 본 연구에서는 GEANT4 toolkit을 이용하여 의료용 선형가속기에 대한 몬테칼로(Monte Carlo) 전산모사를 하였다. Medical Linac2 예제를 수정해서 사용하였다. 에너지스펙트럼, 최빈에너지, 평균에너지를 EGS4 결과와 비교 하였고 선속의 중심에서부터 반경에 따른 단위면적당 광자수, 단위면적당 에너지, 평균에너지를 분석하였다. 그 결과 EGS4 결과와 큰 차이를 보이지 않기 때문에 Medical Linac2 예제의 선속특성에 관한 전산모사에 큰 문제점은 없는 것으로 판단된다. 같은 헤드구조에서도 Physics List의 모델에 따라서는 결과에 차이가 발생하므로 연구 환경에 알맞은 Physics List 모델을 선택하는 것이 중요하다고 판단된다. 본 연구는 처음 몬테칼로 전산모사를 접하는 사용자가 선속특성에 대한 전산모사를 수행하고 6 MV 광자선속의 특성을 분석하는 과정에 많은 도움이 될 것으로 사료된다.

MONTE CARLO SIMULATION FOR CORRECTION OF IONIZATION CHAMBER WALL

  • Kurosawa, Tadahiro;Takata, Nobuhisa;Koyama, Yasuji
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.271-273
    • /
    • 2001
  • In precise measurement of air kerma with cavity ionization chambers, the effect of wall attenuation and scatter are corrected by Kwall and that of nonuniformity by Knu. Using the EGS4 code, we calculated these two correction factors. Correction factors calculated for two different-sized cylindrical ionization chamber differ by up to 0.7% from those obtained by measurements.

  • PDF