• Title/Summary/Keyword: EGS

Search Result 100, Processing Time 0.029 seconds

A Study on Deep Geothermal Energy and Potential of Geothermal Power Generation in Mongolia (몽골의 심부 지열에너지 자원과 지열발전에 관한 연구)

  • Hahn, Jeong-Sang;Yoon, Yun-Sang;Kiem, Young-Seek;Hahn, Chan;Park, Yu-Chul;Mok, Jong-Gu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.1-11
    • /
    • 2012
  • Mongolia has three(3) geothermal zones and eight(8) hydrogeothermal systems/regions that are, fold-fault platform/uplift zone, concave-largest subsidence zone, and mixed intermediate-transitional zone. Average temperature, heat flow, and geothermal gradient of hot springs in Arhangai located to fold-fault platform/uplift zone are $55.8^{\circ}C$, 60~110 mW/m2 and $35{\sim}50^{\circ}C/km$ respectively and those of Khentii situated in same zone are $80.5^{\circ}C$, 40~50 mW/m2, and $35{\sim}50^{\circ}C/km$ separately. Temperature of hydrothermal water at depth of 3,000 m is expected to be about $173{\sim}213^{\circ}C$ based on average geothermal gradient of $35{\sim}50^{\circ}C/km$. Among eight systems, Arhangai and Khentii located in A type hydrothermal system, Khovsgol in B type, Mongol Altai plateau in C type, and Over Arhangai in D type are the most feasible areas to develop geothermal power generation by Enhanced Geothermal System (EGS). Potential electric power generation by EGS is estimated about 2,760 kW at Tsenher, 1,752 kW at Tsagaan Sum, 2,928 kW at Khujir, 2,190 kW at Baga Shargaljuut, and 7,125 kW at Shargaljuut.

The ionization chamber response function from the measured and the corrected by Monte Carlo simulation. (측정된 원통형 전리함 반응함수의 몬테카를로 시뮬레이션 보정)

  • 이병용;김미화;조병철;나상균;김종훈;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.9-17
    • /
    • 1996
  • The response function of ionization chambers are measured in the narrow radiation field Nominal photon energies are 4MV, 6MV and 15MV. the Radii of the chambers are 0.5cm~3.05cm and the field size is 0.2$\times$20$\textrm{cm}^2$. The measurements are taken in the water phantom at 10cm depth. The beam kernel (radiation distribution profile) for narrow radiation field in the phantom are obtained from Monte Carlo simulation (EGS4, Electron Gamma Shower 4). The beam kernel components in the measured chamber response function are deconvolved in order to get the ideal chamber response function of the $\delta$-shaped function radiation field. The chamber response functions have energy dependent tendency before deconvolution, while they show energy invariant properties, after the components of beam kernels are removed by deconvolution method.

  • PDF

Bioavailability and Feed Value of Starfish with Various Treatments (처리방법에 따른 불가사리의 이용율 및 사료적 가치)

  • Choe, H.S.;Park, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • To evaluate the feed value of starfish, antimicrobial effects of its extract, nutrients contents, concentration of amino acids and its bioavailability were tested. Steaming and ether processes were applied to obtain the extract from starfish for antimicrobial effects examination. The starfish was dried at $60^{\circ}C$ for 3 days before grinding for processing and fermentation. Ground starfish(GS), extruded starfish(ES), fermented starfish(EFS) were added with enzyme and without enzyme(Non enzyme fermented starfish : NEFS). Then the nutrient composition and bioavailability of those were analyzed. The extract from starfish showed no inhibition of the growth of lactobacillus and pathogenic bacteria. Protein content showed significantly higher 62.86% and 52.82%, respectively in EFS and NEFS than GS and EGS(p<0.05). The Ca content of GS, EGS, EFS and NEFS was 17.26%, 18.26%, 5.37% and 8.55%, respectively. It was low in EFS and NEFS due to measure the Ca content after fermentation. Total amino acid was 17.17 mg/g, 20.28 mg/g, 36.30 mg/g and 29.96 mg/g in GS, EGS, EFS and NEFS, respectively. The ratio of total amino acid to protein tended to show the similar tendency as total amino acid. Both total amino acid and its ratio to protein were increased by the fermentation. Bioavailability of the protein and Ca showed more 80% in EFS and NEFS. The nutrients availability of EFS were significantly higher in laying hens than other treatments. The results of these experiments indicate that starfish would be applied as a feed ingredients if it was properly treated.

  • PDF

Monte Carlo Simulation for Dose Distributions from Ir-192 in Brachytherapy (근접 방사선치료용 이리듐 선원의 선량분포에 대한 몬데칼로 시뮬레이션)

  • 김승곤;강정구;이정옥;정동혁;문성록
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.187-194
    • /
    • 2002
  • In this work we investigated through Monte Carlo calculations the physical characteristics of the absorbed dose from the Ir-192 source used in brachytherapy The Monte Carlo calculations were performed using the code EGS4, which was extensively modified in order to handle cylindrical sources, phantoms, and energy distributions to suit out own purpose. From the results of the calculations for the $\beta$ -rays, it was found that they contribute on the average 0.02% to The total absorbed dose in the distance range of 0.5-5.0 cm from the source. This is due to the face that, although most of the primary $\beta$ -rays are absorbed in the source and encapsulation material, the resulting low energy braking radiation from them contribute to such a distance. The absorbed dose in the encapsulation material varied on the average from 2.8% for platinum down to 1.1% for iron. The radial dose functions obtained by our Monte Carlo calculations were consistent within $\pm$3% with those of the TG-43 report for the radial distance interval 0.5-10.0 cm from the source. The user code we wrote in this work can be used for other sources of different sizes and so it can be very useful in designing and producing the sources for brachytherapy.

  • PDF

Modeling of SP responses for geothermal-fluid flow within EGS reservoir (EGS 지열 저류층 유체 유동에 의한 SP 반응 모델링)

  • Song, Seo Young;Kim, Bitnarae;Nam, Myung Jin;Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.223-231
    • /
    • 2015
  • Self-potential (SP) is sensitive to groundwater flow and there are many causes to generate SP. Among many mechanisms of SP, pore-fluid flow in porous media can generate potential without any external current source, which is referred to as electrokinetic potential or streaming potential. When calculating SP responses on the surface due to geothermal fluid within an engineered geothermal system (EGS) reservoir, SP anomaly is usually considered to be generated by fluid injection or production within the reservoir. However, SP anomaly can also result from geothermal water fluid within EGS reservoirs experiencing temperature changes between injection and production wells. For more precise simulation of SP responses, we developed an algorithm being able to take account of SP anomalies produced by not only water injection and production but also the fluid of geothermal water, based on three-dimensional finite-element-method employing tetrahedron elements; the developed algorithm can simulate electrical potential responses by both point source and volume source. After verifying the developed algorithm, we assumed a simple geothermal reservoir model and analyzed SP responses caused by geothermal water injection and production. We are going to further analyze SP responses for geothermal water in the presence of water production and injection, considering temperature distribution and geothermal water flow in the following research.

A Study on the Simulation and the Measurement of 6 MeV electron Beam (6 MeV 전자선의 측정과 모의계산에 대한 연구)

  • Lee Sung Ah;Lee Jeong Ok;Moon Sun Rock;Won Jong Jin;Kang Jeong Ku;Kim Seung Kon
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.285-289
    • /
    • 1995
  • Purpose : We compared the calcualted percent depth dose curves of 6 MeV electron beam to that of measured to evaluate the usefulness of Monte-carlo simulation method in radiation physics. Materials and Methods : The radiation dose values of 6 MeV electron beam using EGS4 code with one million histories in water were compared values that were measured from the depth dose curve of electron beam irradiated by medical accelerator ML6M. The central axis dose values were calculated according to the changing field size. such as $5{\times}5,\;10{\times}10,\;15{\times}15,\;20{\times}20cm^2$. Results : The value calculated showed a very similar shape to depth dose curve. The calculated and measured value of $D_max$ at $10{\times}10cm^2$ cone is 15mm and 14mm respectively. The calculated value of the surface radiation dose rate is $65.52\%$ and measured one is $76.94\%$. The surface radiation dose rate has varied from $64.43\%$ to $66.99\%$. The calculated values of $D_max$ are in the range between 15mm and 18mm. The calculated value was fitted well with measured value around the $D_max$ area, excluding build up range and below the $90\%$ depth dose area. Conclusion : This result suggested that the calculation of dose value can be replace the direct measurement of the dose for radiation therapy. Also, EGS4 may be a very convenient program to assess the effect of radiation dose using by personal computers.

  • PDF

Cluster-based Minimum Interference Channel Assignment for Multi-Radio Multi-Channel Wireless Mesh Networks (멀티 라디오 멀티 채널 무선 메쉬 네트워크를 위한 클러스터 기반 최소 간섭 채널 할당)

  • Cha, Si Ho;Ryu, Min Woo;Cho, Kuk Hyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.3
    • /
    • pp.103-109
    • /
    • 2010
  • Total performance is improved by minimizing the channel interference between links in wireless mesh networks (WMNs). The paper refines on the CB-CA [1] to be suitable for multi-radio multi-channel (MRMC) WMNs. The CB-CA is the cluster-based channel assignment algorithm for one radio three channel WMN based on IEEE 802.11b/g. The CB-CA does not perform the channel scanning and the channel switching between the cluster heads (CHs) and the edge gateway nodes (EGs). However, the use of co-channel for links between CHs and EGs brings the problem of channel interference among many nodes. We propose and evaluate an improved CB-CA algorithm to solve this problem in MRMC WMNs. The proposed algorithm discriminates between transmission channel and receive channel and assigns channels to each interface randomly and advertises this information to neighbor clusters in order to be assigned no-interference channel between clusters. Therefore, the proposed algorithm can minimize the interference between clusters and also improve QoS, since it can use multiple interfaces and multiple channels.

Effect of EGS on the Patients with TMJ Pain (EGS가 악관절동통 환자에 미치는 영향)

  • 김영구
    • Journal of Oral Medicine and Pain
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 1984
  • Author could get the result as below after EGS(an electrical nerve stimulator) treatment, one of the pain-reliaving methods, to 30 patients in whom author could confirm the objective improvement of symptoms among the patients who visited SNUH between July the first and December the 31th. 1984. because of TMJ pain. 1. The average number of treatment were 5.5 times/pt., and mean treatment duration was 20 minutes. 2. The severities of pain before the treatment were distressing (46.7%), discomforting (26.7%), mild (20.0%) and horrible (6.7%), but the percentages of them became changed to mild (50%), discomforting (33.3%), none (10%) and distressing (6.7%) after treatment. 3. The activities of mouth opening before the treatment were moderately restricted (53.3 %), serverely restricted (33.3%) and slightly restricted (13.3%), but the percentages of them became changed to slightly restricted (66.7%), normal (16.7%), modorately restricted (13.3%) and severely restricted (3.3%) after treatment. 4. The effects of the pain upon one's personality before treatment were severely upset (43.3%), moderately upset (36.7%), slightly upset(16.7%) and normal (3.3%), but the percentages of them became changed to slightly upset (50%), normal (33.3%), morderately upset (10%) and severely upset (6.7%) after treatment.

  • PDF