• Title/Summary/Keyword: EEG measurement

Search Result 163, Processing Time 0.028 seconds

A Study of EEG Characteristics by auditory stimuli of Emotional music (감정 음악별 청각자극에 따른 뇌파특성 연구)

  • Choi, Nam-Sook;Im, Giyong;Jung, Chul-Woo;Lee, Hyeob-Eui;Wi, Hyun-Wook;Park, Pyong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.608-616
    • /
    • 2017
  • The purpose of this study was to compare how three kinds of emotionally different music impacted on the emotion and arousal by measuring EEG. The research method was to compare the measurement of the background EEG on Fp1 and Fp2 before, while and after listening using a 2-channel EEG device with various experimental groups aging from 20s to 50s. The results were as follows. 1) At both Fp1 and Fp2, the amplitude of alpha(8-13Hz), SMR(12-15Hz), low beta, high beta, and ${\alpha}/-{\beta}$significantly increased in all music, while at Fp2 only, theta and ??/SMR increased meaningfully.2) At right prefrontal cortex(Fp2), all bands of EEG predominated while and after listening to all songs over Fp1 except for the delta of funeral march which predominated while listening to Fp1.3) The music with a noticeably high alpha value and increased activity was Prelude. These results suggested that Prelude induced brain activity along with relaxation, and the emotionally heavy burden of funeral march decreased the activity of the left brain. This research revealed that feeling emotional change by listening to music was due to the fact that music influenced the brain activity inducing the change of emotion and arousal.

The Effects of Acupuncture on the Electroencephalogram of Patients with Stroke (자침이 중풍환자의 뇌파 변화에 미치는 영향)

  • Yoon, Ga-Young;Park, Ji-Min;Kim, Dong-Hyuk;Seon, Jong-In;Kang, Jung-Won;Nam, Dong-Woo;Lee, Seung-Deok;Choi, Do-Young;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.1-16
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the effects of manual acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ on Electroencephalogram(EEG) of patients with stroke. Methods : 32 channel EEG measurement was carried out in 35 Stroke patients(23 males and 12 females). EEG was measured for 21 minutes(made up of 7 sessions, 1 session means 3 minutes time interval) including 15 minutes(5 sessions) of acupuncture time. Power spectrum analysis was used as a measure of complexity. Statistical analysis was performed using Linear mixed model and DUNNETT's multiple comparison. Results : The results were as follows; 1. EEG amplitude was reduced during acupuncture except electrodes PG1 and PG2. 2. There was a notable change during 6~9 minutes after needling in ${\delta}{\cdot}{\beta}{\cdot}{\gamma}$ wave, and during 6~9 minutes after needling in ${\Theta}{\cdot}{\alpha}$ wave. Overall, during 6~9 minutes after needling. 3. TP8 is a common significant electrode among five wave forms. Conclusions : These results suggest that TP8 could be typical electrodes and change of EEG compared to baseline happens most often during 6~9 minutes after manipulated acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ of patients with stroke.

Development of Mirror Neuron System-based BCI System using Steady-State Visually Evoked Potentials (정상상태시각유발전위를 이용한 Mirror Neuron System 기반 BCI 시스템 개발)

  • Lee, Sang-Kyung;Kim, Jun-Yeup;Park, Seung-Min;Ko, Kwang-Enu;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.1
    • /
    • pp.62-68
    • /
    • 2012
  • Steady-State Visually Evoked Potentials (SSVEP) are natural response signal associated with the visual stimuli with specific frequency. By using SSVEP, occipital lobe region is electrically activated as frequency form equivalent to stimuli frequency with bandwidth from 3.5Hz to 75Hz. In this paper, we propose an experimental paradigm for analyzing EEGs based on the properties of SSVEP. At first, an experiment is performed to extract frequency feature of EEGs that is measured from the image-based visual stimuli associated with specific objective with affordance and object-related affordance is measured by using mirror neuron system based on the frequency feature. And then, linear discriminant analysis (LDA) method is applied to perform the online classification of the objective pattern associated with the EEG-based affordance data. By using the SSVEP measurement experiment, we propose a Brain-Computer Interface (BCI) system for recognizing user's inherent intentions. The existing SSVEP application system, such as speller, is able to classify the EEG pattern based on grid image patterns and their variations. However, our proposed SSVEP-based BCI system performs object pattern classification based on the matters with a variety of shapes in input images and has higher generality than existing system.

Stress status classification based on EEG signals (뇌파 신호 기반 스트레스 상태 분류)

  • Kang, Jun-Su;Jang, Giljin;Lee, Minho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • In daily life, humans get stress very often. Stress is one of the important factors of healthy life and closely related to the quality of life. Too much stress is known to cause hormone imbalance of our body, and it is observed by the brain and bio signals. Based on this, the relationship between brain signal and stress is explored, and brain signal based stress index is proposed in our work. In this study, an EEG measurement device with 32 channels is adopted. However, only two channels (FP1, FP2) are used to this study considering the applicability of the proposed method in real enveironment, and to compare it with the commercial 2 channel EEG device. Frequency domain features are power of each frequency bands, subtraction, addition, or division by each frequency bands. Features in time domain are hurst exponent, correlation dimension, lyapunov exponent, etc. Total 6 subjects are participated in this experiment with English sentence reading task given. Among several candidate features, ${\frac{{\theta}\;power}{mid\;{\beta}\;power}}$ shows the best test performance (70.8%). For future work, we will confirm the results is consistent in low price EEG device.

The Brand Identity Design Evaluation Using EEG Measurement (뇌전도를 활용한 브랜드 아이덴티티 디자인 평가)

  • Han, Yu-Rim;Kim, Da-Sol;Han, Ji-Ae;You, Sicheon
    • Smart Media Journal
    • /
    • v.7 no.4
    • /
    • pp.106-113
    • /
    • 2018
  • Brand identity (BI) is a key asset that affects consumers' psychological cognition of products and services. In the initial planning stage of the BI design development for a company, a unique approach strategy is required. In the final evaluation stage, a reasonable design evaluation method involving potential consumers needs to be prepared. However, conventional brand identity design evaluation processes tend to depend on the results of surveys, and in many cases it is impossible to be free from the distorting phenomenon of survey respondents' psychological manifestation which is often revealed in the process of the surveys. In this context, this research has explored whether the method of utilizing EEG data of the subjects along with the conventional survey method of preference could be helpful in the process of evaluating the brand identity design. To achieve that, we correlated the subject's preference survey results with the subject's EEG data. 'Attractiveness' and 'concentration' were used as variables. As a result, it was found that there was a high correlation between the results of preference survey on 'attractiveness' and the results of 'EEG' on 'concentration'. Therefore, in addition to the existing conventional qualitative evaluation methods, we confirmed that design evaluation methods using EEG are useful for evaluating tacit knowledge objects such as the BI design.

Validity examination of the measurement of 3D visual fatigue using EEG (EEG 생체신호 기반 3D 시각피로 측정방법에 대한 타당화 연구)

  • Li, Hyung-Chul O.;Moon, Kyung-Ae
    • Science of Emotion and Sensibility
    • /
    • v.15 no.1
    • /
    • pp.17-28
    • /
    • 2012
  • Recent development of 3D technologies made it possible that observers perceive 3D depth from two dimensional images. Despite this kind of technological development, when observers watch 3D display they experience 3D visual fatigue that they do not usually experience in real life. It is critical to measure visual fatigue in order to overcome the problem of 3D visual fatigue. The purpose of the present study was to develop a protocol to measure 3D visual fatigue based on an EEG signal and to examine its validity. The first experiment explored the possible ERP components that reflected visual fatigue in 2D and 3D conditions. The second experiment examined whether the feature of the component found in the first experiment was affected by the amount of binocular disparity. Both in Cz and Pz channels, the peak amplitude of P3 component was much lower in 3D rather than in 2D conditions, and it decreased as the amount of binocular disparity increased. The subjective 3D visual fatigue also increased with the amount of binocular disparity. These results imply that the peak amplitude of P3 component at Cz and Pz channels can be used as an index of 3D visual fatigue.

  • PDF

Biological Signal Measurement, Archiving, and Communication System (SiMACS) (생체신호 측정 및 종합관리 시스템 (SiMACS))

  • Woo, Eung-Je;Park, Seung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF

Human Sensibility Measurement or the Visual Picture Stimulus (장면 시자극에 대한 감성측정에 관한 연구)

  • Kim, D.S.;Kim, D.Y.;Lim, Y.H.;Shon, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.23-26
    • /
    • 1997
  • We present several biosignal measurement results and analysis algorithms or the visual stimulus from International Affective Picture System. Since human body is nonlinear dynamic system, we investigated both linear and nonlinear methods. We found that the chaos was diminished when unpleasant picture is presented relative to pleasant picture, and the alpha wave of EEG was slightly augmented in pleasant picture, but was not convincing result. These can be used as the parameter or the measurement of human sensibility.

  • PDF

The Effects of Acupuncture Stimulation on Acupoints Related to Mind (정신기능과 관련된 경혈에 대한 침 자극이 인체에 미치는 영향)

  • Lee, Seung-Gi;Choi, Woo-Jin;Shim, Seong-Youn
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.2
    • /
    • pp.85-99
    • /
    • 2009
  • Objectives : This study aimed to understand the influence of acupuncture on the human body by comparing changes within human bodies before and after people in normal health are treated with acupuncture at the acupoints HT7 and PC9, which are related to mental functions. Methods : The study was performed from January 3, 2008 to March 5, 2008 on 60 healthy males and females in their 20s. HRV, EEG, skin conductance response, respiration and peripheral skin temperature were measured for 5 minutes before acupuncture simulation was applied to the acupoints HT7 and PC9. During 20 minutes of acupuncture treatment, the same items were continuously measured to determine whether there had been any changes, and they were then measured for 5 minutes after the removal of the acupuncture needles in order to implement a comparative analysis. Results : 1. The HRV measurement showed that in the course of before, during and after acupuncture stimulation, heart rate, HF and HF norm decreased significantly (P<0.05) at HT7. LF, LF norm, and LF/HF ratio increased significantly (P>0.05), while heart rate, HF and HF norm decreased significantly (P<0.05) at PC9. 2. Skin conductance response increased significantly (P<0.05) at PC9 during and after the acupuncture simulation periods, compared with the pre acupuncture period. 3. the peripheral skin temperature increased significantly (P<0.05) both at HT7 and PC9 in the course of before, during and after acupuncture stimulation. 4. Compared with the pre-acupuncture period, respiration rate increased both at HT7 and at PC9 during and after the acupuncture simulation periods, but not in a statistically significance. 5. In the EEG measurement, when compared with the pre-acupuncture period at HT7, mid ${\beta}$ wave decreased significantly (P<0.05) during acupuncture treatment. Compared with the measurements during acupuncture treatment at PC9, low ${\beta}$ wave increased significantly (P<0.05) after the acupuncture needles were removed. Conclusions : When acupuncture treatment is applied at the acupoints HT7 and PC9, the activation of parasympathetic nerves decreases and the activation of sympathetic nerves increases in the HRV measurement. It was determined that PC9 makes the sympathetic nerves become highly activated in a skin conduction response. The effect of stability in the brain wave seemed to bo shown at HT7 than PC9.

  • PDF