• 제목/요약/키워드: EDG

검색결과 65건 처리시간 0.027초

Seismic performance of emergency diesel generator for high frequency motions

  • Jeong, Young-Soo;Baek, Eun-Rim;Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1470-1476
    • /
    • 2019
  • The nuclear power plants in South Korea have been designed in accordance with the U.S. Regulatory Guide 1.60 (R.G 1.60) design spectrum of which the peak frequency range is 2-10 Hz. The characteristics of the earthquakes at the Korea nuclear power plant sites were observed to be closer to that of Central and Eastern United States (CEUS) than the R.G 1.60, which is a lower amplification in a low frequency range, and a higher amplification in a high frequency range. The possibility of failure for sensitive power plant components in the high frequency range has been considered and evaluated. In this study, in order to improve the reliability of nuclear plant and administrative control procedures, seismic tests of an emergency diesel generator (EDG) were conducted using a shaking table under both high and low frequency ranges. From the tests, oil/lubricant leaks from the bolt connections, the fuel filter and the fuel inlet were observed. Therefore, the check list of nuclear plant components after an earthquake should include bolt connections of EDG as well as anchor bolts.

Michael-type Reactions of 1-(X-substituted phenyl)-2-propyn-1-ones with Alicyclic Secondary Amines in MeCN and H2O: Effect of Medium on Reactivity and Transition-State Structure

  • Kim, Song-I;Hwang, So-Jeong;Park, Yoon-Min;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1199-1203
    • /
    • 2010
  • Second-order rate constants ($k_N$) have been measured spectrophotometrically for Michael-type reactions of 1-(X-substituted phenyl)-2-propyn-1-ones (2a-f) with a series of alicyclic secondary amines in MeCN at $25.0{\pm}0.1^{\circ}C$. The $k_N$ value increases as the incoming amine becomes more basic and the substituent X changes form an electron-donating group (EDG) to an electron-withdrawing group (EWG). The Br${\o}$nsted-type plots are linear with ${\beta}_{nuc}$ = 0.48 - 0.51. The Hammett plots for the reactions of 2a-f exhibit poor correlations but the corresponding Yukawa-Tsuno plots result in much better linear correlations with ${\rho}$ = 1.57 and r = 0.46 for the reactions with piperidine while ${\rho}$ = 1.72 and r = 0.39 for those with morpholine. The amines employed in this study are less reactive in MeCN than in water for reactions with substrates possessing an EDG, although they are ca. 8 pKa units more basic in the aprotic solvent. This indicates that the transition state (TS) is significantly more destabilized than the ground state (GS) in the aprotic solvent. It has been concluded that the reactions proceed through a stepwise mechanism with a partially charged TS, since such TS would be destabilized in the aprotic solvent due to the electronic repulsion between the negative-dipole end of MeCN and the negative charge of the TS. The fact that primary deuterium kinetic effect is absent supports a stepwise mechanism in which proton transfer occurs after the rate-determining step.

Aminolysis of S-4-Nitrophenyl X-Substituted Thiobenzoates: Effect of Nonleaving-Group Substituents on Reactivity and Mechanism

  • Im, Li-Ra;Jeon, Sang-Eun;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권4호
    • /
    • pp.1153-1157
    • /
    • 2011
  • A kinetic study is reported for aminolysis of S-4-nitrophenyl X-substituted thiobenzoates 3a-g in 80 mol % $H_2O$/20 mol % DMSO at $25.0{\pm}0.1^{\circ}C$. Thiol esters 3a-g are 7.8-47.6 fold more reactive than the corresponding oxygen esters (i.e., 4-nitrophenyl X-substituted benzoates 1a-g). Such reactivity order appears to be in accordance with the expectation that 4-nitrothiophenoxide in 3a-g is a better nucleofuge than 4-nitrophenoxide in 1a-g since the former is 2.64 pKa units less basic than the latter. Hammett plot for the reactions of 3a-g exhibit poor correlation coefficients ($R^2$ = 0.977-0.986) with negative deviation by substrates possessing an electrondonating group (EDG), while the Yukawa-Tsuno plots result in excellent linear correlation ($R^2$ = 0.995-0.997) with ${\rho}$ = 0.93-1.23 and r = 0.57-0.67, indicating that the negative deviation shown by substrates possessing an EDG is caused by ground-state stabilization through resonance interactions but not due to a change in ratedetermining step upon changing the nonleaving-group substituent X. The ${\rho}$ value increases as the incoming amine becomes more basic and more reactive, indicating that the RSP is not operative in the current reactions.

원자력발전소 비상디젤발전기 상태감시 기술 적용 연구 (Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant)

  • 최광희;박종혁;박종은;이상국
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

원전 안전등급 저전압계전기 설정시 오차함수 검토 (Review on tolerance factors for 1E UVR setting at NPPs)

  • 문수철;김건중
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.367-372
    • /
    • 2012
  • In nuclear plants, UVR (under voltage relay, 27r) of 1E bus, which protected and supplied power to essential loads, to safety trip of reactor and supplied to starting signal of EDG (emergency diesel generators) automatically. therefore UVR tolerances setting and calculation method has been important to nuclear facility. If calculation and tolerances values differ or ignore, may induced power loss and economical loss by protective failure. This paper show results for calculation methods, and whether dependant or independent methods for factors. included whether PT (potential transformer/voltage transformer) tolerance or not adapted, and based on UVR setting method within a difference minimum and maximum of rated voltage to safety operation in nuclear plants.

형식 도구를 이용한 이산사건 시뮬레이션의 모델 형식화 방법론 (A Model Formalization Methodology of Discrete Event Simulation with Formal Tools)

  • 정영식;황종선
    • 한국경영과학회지
    • /
    • 제17권3호
    • /
    • pp.79-99
    • /
    • 1992
  • The DEVS (Discrete Event system Specification) formal model for discrete event simulation is a hierarchical, modular model. Because the DEVS formal model has a mathematical structure, it provides a theoretic background of discrete event simulation model. However, the DEVS formal model is difficult to understand because of its mathematical structure. Also, since the DEVS formal model is often constructed by heuristic, subjective method of model designer from the model, a systematic model built-in methodology does not exist. In this paper, we propose the model formalization methodology from an informal model to the DEVS formal model. For this formalization methodology, we introduce formal tools for model construction based on the DEVS ( from an informal model : Event Dependency Graph (EDG) for the event analysis and State Representation Graph(SRG) for the system state analysis.

  • PDF

경수로형 원자력 안전등급 비상디젤발전기 (Governor upgrade for PWR NPP safety related Emergency Diesel Generator)

  • 김윤식;전일영;송동영;김창국;심수일
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.293-298
    • /
    • 2005
  • The following is final report for governor upgrade for PWR NPP safety related EDG Kori NPP No.2 Unit. The upgraded system includes more beneficial function like as "Slow start with starting ramp", "Generator load sensing & control capability" and "Emergency ramp during slow start". This paper show functional operation of slow start regime according to NRC regulatory guide which guide regulation to NPP safety related environment.

  • PDF

원전 비상디젤발전기 여자시스템 개발 (Development of Diesel Generator Excitation System in the Nuclear Power Plant)

  • 신만수;류호선;이주현;임익헌;정태원
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.397-406
    • /
    • 2010
  • Because diesel generator excitation systems in the nuclear power generating station are included among safety related c1asses(and Class 1E), they have been supposed to apply in the nuclear power generating stations through equipment qualification by nuclear law and so on. So, they has been controlled and assured completely by quality assurance throughout the total development journey. This paper looks into the journey of development of diesel generator excitation systems in the nuclear power generating station.

원전 안전등급 비상디젤발전기 속도제어시스템 성능개선 및 분석에 관한 연구 (Performance upgrade and analysis report for nuclear safety related emergency diesel generator speed control system)

  • 김윤식;전일영;이성근;김창국;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.581-583
    • /
    • 2005
  • The paper is final report for speed control upgrade and analysis report which recently performed on PWR NPP safety related EDG KHNP Ulchin NPP No.2 Unit. The upgraded system includes more beneficial function like as 'Slow start with starting ramp', 'Generator load sensing & control capability' and 'Emergency ramp during slow start'. This paper shows functional operation of slow start regime according to NRC regulatory guide which guide regulation to NPP safety related environment.

  • PDF

에지 검출을 위한 통계적 검정법 (Statistical Tests for Edg Detection)

  • 임동훈;성신희
    • 한국정보처리학회논문지
    • /
    • 제7권3호
    • /
    • pp.1021-1024
    • /
    • 2000
  • In this paper we describe a nonparametric Wilcoxon test and a parametric Z test based on statistical hypothesis testing for the detection of edges. We use the threshold determined by specifying significance level $\alpha$, while Bovik, Huang and Munson[4] consider the range of possible values of test statistics for the threshold. From the experimental results of edge detection, the Z method performs sensitively to the noisy image, while the Wilcoxon method is robust over both noisy nd noise-free images. Comparison with our statistical tests and Sobel operator shows that our tests perform more effectively in both noisy and noise-free images.

  • PDF